Controller - SOL-SA-PCU-41XX-5MW - 1186852
1186852
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:

Mechanical design

Weight
215 g

Dimensions

Width
45 mm
Height
126.93 mm
Depth
75 mm

PROFINET

Device function
PROFINET controller, PROFINET device
Specification
Version 2.3
Update rate
min. 1 ms (4 devices)
Update rate
min. 16 ms (64 devices)

Control system

Engineering tool
PLCnext Engineer
Engineering tool
Eclipse
Programming languages supported
Programming in acc. with IEC 61131-3
Programming languages supported
C++
Programming languages supported
C#
Programming languages supported
Java
Programming languages supported
Manufacturer-specific
Supports cloud computing
yes
Cloud platform
Proficloud

General data

Operating system
Linux

Ambient conditions

Degree of protection
IP20
Ambient temperature (operation)
-25 °C - 60 °C up to 2000 m above mean sea level (observe derating)
Ambient temperature (operation)
-25 °C - 55 °C up to 3000 m above mean sea level (observe derating)
Ambient temperature (operation)
≤ 55 °C (with max. 1 A on UBus)
Ambient temperature (operation)
> 55 °C - 60 °C (only in conjunction with an Axioline F power module AXL F PWR 1H (order number 2688297))
Ambient temperature (storage/transport)
-40 °C - 85 °C
Permissible humidity (operation)
5 % - 95 % (according to DIN EN 61131-2)
Permissible humidity (storage/transport)
5 % - 95 % (according to DIN EN 61131-2)
Air pressure (operation)
70 kPa - 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)
58 kPa - 106 kPa (up to 4500 m above mean sea level)
Shock
30g, 11 ms period, half-sine shock pulse, according to IEC 60068-2-27
Vibration (operation)
5g

IEC 61131 runtime system

Engineering tool
PLCnext Engineer
Engineering tool
Eclipse
Program memory
8 Mbyte
Mass storage
16 Mbyte
Retentive mass storage
48 kByte (NVRAM)
Realtime clock
Yes

Standards and Regulations

Electromagnetic compatibility
Conformance with EMC Directive 2014/30/EU
Interference emission
Noise emission test as per EN 61000-6-4 Class A
Immunity to surge
Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical), fieldbus cable shield: ±1 kV
Immunity to burst
Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV
Immunity to EF
Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
Immunity to ESD
Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
Immunity to conducted interference
Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
Vibration (storage/transport)
5g
Shock
30g, 11 ms period, half-sine shock pulse, according to IEC 60068-2-27
Vibration (operation)
5g
Shock (operation)
10g (Bump endurance test according to DIN EN 60068-2-27)

Fieldbus function

Designation
System limits of the controller
Amount of process data
max. 4096 Bit (Input)
Amount of process data
max. 4096 Bit (Output)
Number of supported devices
max. 63 (per station)
Number of local bus devices that can be connected
max. 63 (observe current consumption)
Program memory
8 Mbyte

Data interfaces

Interface
Axioline F local bus
Number
1
Connection method
Bus base module
Number
2
Connection method
RJ45 jack