Phoenix Contact
1402687
Network cable - VS-OE-OE-937/... - 1402687
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Send request for price
1
Payment methods:
Cable
- Cable type
- PROFINET RADOX® railway application CAT5
- Cable type (abbreviation)
- 937
- Signal type/category
- PROFINET CAT5 (IEC 11801), 100 Mbps
- Signal type/category
- EtherCAT® CAT5 (IEC 11801), 100 Mbps
- Cable structure
- 1x4xAWG22/7; SF/TQ
- Conductor cross section
- 4x 0.34 mm²
- AWG signal line
- 22
- Conductor structure signal line
- 7x 0.25 mm
- Core diameter including insulation
- approx. 1.5 mm
- Wire colors
- white-blue, orange-yellow
- Overall twist
- Star quad
- Shielding
- Plastic-coated aluminum foil, tinned copper braided shield
- External sheath, color
- black RAL 9005
- Outer sheath thickness
- approx. 1 mm
- External cable diameter D
- 6.6 mm ±0.4 mm
- Minimum bending radius, fixed installation
- 6 x D
- Cable weight
- 70 kg/km
- Outer sheath, material
- PE-X
- Material conductor insulation
- Foamed PE
- Conductor material
- silver-plated Cu litz wires
- Conductor resistance
- ≤ 54.4 Ω/km
- Working capacitance
- ≤ 65 pF (core-core)
- Working capacitance
- ≤ 100 pF (core-shield)
- Wave impedance
- 100 Ω ±5 Ω (f = 100 MHz)
- Near end crosstalk attenuation (NEXT)
- 73 dB (with 1 MHz)
- Near end crosstalk attenuation (NEXT)
- 70 dB (at 4 МHz)
- Near end crosstalk attenuation (NEXT)
- 65 dB (at 10 MHz)
- Near end crosstalk attenuation (NEXT)
- 57 dB (at 31.5 МHz)
- Near end crosstalk attenuation (NEXT)
- 52 dB (at 62.5 МHz)
- Near end crosstalk attenuation (NEXT)
- 48 dB (at 100 MHz)
- Remote crosstalk attenuation (FEXT)
- 78 dB (with 1 MHz)
- Remote crosstalk attenuation (FEXT)
- 77 dB (at 4 МHz)
- Remote crosstalk attenuation (FEXT)
- 70 dB (at 10 MHz)
- Remote crosstalk attenuation (FEXT)
- 65 dB (at 31.5 МHz)
- Remote crosstalk attenuation (FEXT)
- 56 dB (at 62.5 МHz)
- Remote crosstalk attenuation (FEXT)
- 48 dB (at 100 MHz)
- Attenuation
- 2 dB (with 1 MHz)
- Attenuation
- 4.4 dB (at 4 МHz)
- Attenuation
- 7.4 dB (at 10 MHz)
- Attenuation
- 14 dB (at 31.5 МHz)
- Attenuation
- 20 dB (at 62.5 МHz)
- Attenuation
- 26 dB (at 100 MHz)
- Return loss (RL)
- 25 dB (at 4 МHz)
- Return loss (RL)
- 30 dB (at 10 MHz)
- Return loss (RL)
- 30 dB (at 31.5 МHz)
- Return loss (RL)
- 30 dB (at 62.5 МHz)
- Return loss (RL)
- 28 dB (at 100 MHz)
- Signal speed
- 75 c
- Shield attenuation
- 40 dB (30 MHz ≤ f ≤ 100 MHz)
- Coupling resistance
- 200.00 mΩ/m (f ≤ 30 MHz)
- Nominal voltage, cable
- 300 V AC
- Test voltage, cable
- 2000 V AC (50 Hz, 5 minutes)
- Fire protection in rail vehicles
- BS 6853 (Category Ia, Ib, II)
- Fire protection in rail vehicles
- GM/RT 2130 (Category Ia, Ib, II)
- Fire protection in rail vehicles
- EN 45545 (Risk level HL1 - HL3)
- Fire protection in rail vehicles
- DIN 5510 (Fire protection level 1, 2, 3, 4)
- Fire protection in rail vehicles
- NF F16-101 (Category A1, A2, B)
- Fire protection in rail vehicles
- NF F16-101 (Class C/F0)
- Fire protection in rail vehicles
- NFPA 130
- Fire protection in rail vehicles
- UNI CEI 11170 (Risk level LR1 - LR4)
- Flame resistance
- EN 60332-1-2
- Flame resistance
- EN 50266
- Flame resistance
- EN 60332-3-25
- Flame resistance
- NF C32-070, 2.1
- Flame resistance
- NF C32-070, 2.2
- Flame resistance
- UL 1685, 12 (FT4)
- Flame resistance
- in accordance with ISO 6722-1 5.22 (UN ECE-R 118.01)
- Halogen-free
- According to EN 50267-2-1
- Resistance to oil
- according to IRM 902, 72 h at 100 °C
- Other resistance
- Resistance to fuels according to IRM 903, 168 h at 70 °C
- Concentration of fumes
- BS 6853 D.8.7
- Concentration of fumes
- EN 61034-2
- Concentration of fumes
- UL 1685, 12 (FT4)
- Fume corrosiveness
- EN 50267-2-2
- Fume toxicity
- BS 6853 B.1
- Fume toxicity
- EN 50305, 9.2
- Ambient temperature (operation)
- -50 °C - 90 °C (cable, fixed installation)
- Ambient temperature (operation)
- -40 °C - 90 °C (cable, flexible installation)
- Ambient temperature (installation)
- -25 °C - 90 °C
Environmental Product Compliance
- China RoHS
- Environmentally friendly use period: unlimited = EFUP-e
- China RoHS
- No hazardous substances above threshold values
General data
- Number of positions
- 4
- Signal type/category
- PROFINET CAT5 (IEC 11801:2002), 100 Mbps
Dimensions
- Length of cable
- Free entry (0.5 - 400 m)