Sensor/actuator cable - SAC-4P-MR-FR SH SCO BK/.../... - 1405898
1405898
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

PVC yellow 105 °C [542]

Cable type
PVC yellow 105 °C
Cable type (abbreviation)
542
UL AWM style
2517 (105 °C / 300 V)
AWG signal line
22
Conductor structure signal line
30x 1.30 mm
Core diameter including insulation
1.27 mm ±0.03 mm
Wire colors
brown, blue, black, white
Overall twist
4 wires, twisted
Shielding
Tinned copper braided shield
Optical shield covering
85 %
External sheath, color
yellow
External cable diameter D
5.5 mm ±0.2 mm
Minimum bending radius, flexible installation
12 x D
Cable weight
48 kg/km
Outer sheath, material
PVC
Material conductor insulation
PVC
Conductor material
Tin-plated Cu litz wires
Insulation resistance
≥ (550 M Ohms/m @ 500V)
Conductor resistance
max. 50.5 Ω/km (20 °C)
Nominal voltage, cable
300 V
Special properties
UL standards PLTC and ITC
Flame resistance
FT4
Other resistance
UV resistant
Ambient temperature (operation)
-30 °C - 105 °C (cable, fixed installation)
Ambient temperature (operation)
-5 °C - 105 °C (cable, flexible installation)

PUR halogen-free yellow [240]

Cable type
PUR halogen-free yellow
Cable type (abbreviation)
240
Cable abbreviation
Li9YV1-C-V1-11Y
UL AWM style
20549
Conductor cross section
4x 0.34 mm²
AWG signal line
22
Conductor structure signal line
42x 0.10 mm
Core diameter including insulation
1.27 mm ±0.02 mm
Thickness, insulation
≥ 0.21 mm
Wire colors
brown, white, blue, black
Overall twist
4 wires, twisted
Length of twist, overall twist
50 mm
Shielding
Braided copper wires
Optical shield covering
85 %
External sheath, color
yellow
Outer sheath thickness
approx. 1 mm
External cable diameter D
5.9 mm ±0.2 mm
Minimum bending radius, fixed installation
5 x D
Minimum bending radius, flexible installation
10 x D
Number of bending cycles
2000000
Minimum bending radius, drag chain applications
10 x D
Traversing path
10 m
Traversing rate
3 m/s
Acceleration
10 m/s²
Cable weight
46 kg/km
Outer sheath, material
PUR
Material conductor insulation
PP
Conductor material
Bare Cu litz wires
Insulation resistance
≥ 1 GΩ*km (at 20 °C)
Conductor resistance
58 Ω/km (at 20 °C)
Nominal voltage, cable
≤ 300 V AC
Test voltage, cable
≥ 3000 V AC (Spark test)
Test voltage Core/Shield
≥ 2000 V AC (for 60 s)
Flame resistance
in accordance with UL 758/1581 FT2
Halogen-free
in accordance with DIN VDE 0472 part 815
Halogen-free
According to EN 50267-2-1
Resistance to oil
According to DIN EN 60811-2-1, 168 h at 100°C
Resistance to oil
According to UL 758, 168 h at 60°C
Other resistance
hydrolysis and microbe resistant
Other resistance
Resistant to salt water
Other resistance
abrasion-resistant
Other resistance
Low adhesion
Ambient temperature (operation)
-40 °C - 80 °C (cable, fixed installation)
Ambient temperature (operation)
-25 °C - 80 °C (cable, flexible installation)

Dimensions

Length of cable
Free input (0.2 - 40.0 m)

Black PVC 105°C [535]

Cable type
Black PVC 105°C
Cable type (abbreviation)
535
UL AWM style
2517 (105 °C / 300 V)
AWG signal line
22
Conductor structure signal line
30x 1.30 mm
Core diameter including insulation
1.27 mm ±0.03 mm
Wire colors
brown, blue, black, white
Overall twist
4 wires, twisted
Shielding
Tinned copper braided shield
Optical shield covering
85 %
External sheath, color
black
External cable diameter D
5.5 mm ±0.2 mm
Minimum bending radius, flexible installation
12 x D
Cable weight
48 kg/km
Outer sheath, material
PVC
Material conductor insulation
PVC
Conductor material
Tin-plated Cu litz wires
Nominal voltage, cable
300 V
Special properties
UL standards PLTC and ITC
Flame resistance
FT4
Other resistance
UV resistant
Ambient temperature (operation)
-30 °C - 105 °C (cable, fixed installation)

Material

Flammability rating according to UL 94
HB
Contact material
CuSn
Contact surface material
Ni/Au
Contact carrier material
TPU GF
Material of grip body
TPU, hardly inflammable, self-extinguishing
Material, knurls
Zinc die-cast, nickel-plated

PUR halogen-free black [PUR]

Cable type
PUR halogen-free black
Cable type (abbreviation)
PUR
Cable abbreviation
Li9Y-V1-C-V1-11Y
UL AWM style
20549 / 10493 (80°C/300 V)
Conductor cross section
4x 0.34 mm² (Signal line)
AWG signal line
22
Conductor structure signal line
42x 0.10 mm
Core diameter including insulation
1.27 mm ±0.02 mm (Signal line)
Thickness, insulation
≥ 0.21 mm
Wire colors
brown, white, blue, black
Overall twist
4 wires, twisted
Shielding
Tinned copper braided shield
Optical shield covering
80 %
External sheath, color
black-gray RAL 7021
Outer sheath thickness
approx. 0.5 mm
External cable diameter D
4.95 mm ±0.2 mm
Minimum bending radius, fixed installation
5 x D
Minimum bending radius, flexible installation
10 x D
Number of bending cycles
10000000
Minimum bending radius, drag chain applications
10 x D
Traversing path
10 m
Traversing rate
3 m/s
Acceleration
10 m/s²
Cable weight
36 kg/km
Outer sheath, material
PUR
Material conductor insulation
PP
Conductor material
Bare Cu litz wires
Insulation resistance
≥ 100 GΩ*km (at 20 °C)
Conductor resistance
max. 58 Ω/km (at 20 °C)
Cable capacity
≤ 80 pF/m (Conductor-Conductor)
Cable capacity
≤ 135 pF/m (Wire/shield)
Wave impedance
≥ 62 Ω (f = 10 MHz)
Conductor inductance
approx. 0.75 mH/km (f = 1 kHz)
Nominal voltage, cable
≤ 300 V
Test voltage, cable
≥ 3000 V
Special properties
Flexible cable conduit capable
Special properties
Silicone-free
Special properties
Free of substances which would hinder coating with paint or varnish
Special properties
Low adhesion surface
Flame resistance
in accordance with UL 758/1581 FT2
Flame resistance
DIN EN 60332-2-2 (20 s)
Halogen-free
in accordance with DIN VDE 0472 part 815
Halogen-free
in accordance with DIN EN 50267-2-1
Resistance to oil
in accordance with DIN EN 60811-2-1
Other resistance
Highly resistant to acids, alkaline solutions and solvents
Other resistance
hydrolysis and microbe resistant
Other resistance
Resistant to salt water
Other resistance
partly UV-resistant in accordance with DIN EN ISO 4892-2-A
Other resistance
abrasion-resistant
Ambient temperature (operation)
-40 °C - 80 °C (cable, fixed installation)
Ambient temperature (operation)
-25 °C - 80 °C (cable, flexible installation)

Ambient conditions

Ambient temperature (operation)
-25 °C - 90 °C (Plug / socket)
Degree of protection
IP65
Degree of protection
IP67

Line characteristics

Note
This item is a sensor/actuator cable with a freely selectable cable type. The technical data for all possible cable types is listed in the table below.

Environmental Product Compliance

China RoHS
Environmentally Friendly Use Period = 50 years
China RoHS
For details about hazardous substances go to tab 'Downloads', Category 'Manufacturer's declaration'

Standards and Regulations

Flammability rating according to UL 94
HB