1405902

Sensor/actuator cable - SAC-4P-M 8MS-M 8FS BK/.../... - 1405902
1405902
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up

PVC yellow 105 °C [542]

Cable type
PVC yellow 105 °C
Cable type (abbreviation)
542
UL AWM style
2517 (105 °C / 300 V)
AWG signal line
24
Conductor structure signal line
32x 1.10 mm
Core diameter including insulation
1.12 mm ±0.03 mm
Wire colors
brown, blue, black, white
Overall twist
4 wires, twisted
External sheath, color
yellow
External cable diameter D
4.4 mm ±0.2 mm
Minimum bending radius, flexible installation
8 x D
Cable weight
25 kg/km
Outer sheath, material
PVC
Material conductor insulation
PVC
Conductor material
Tin-plated Cu litz wires
Insulation resistance
≥ (550 M Ohms/m @ 500V)
Conductor resistance
max. 79.7 Ω/km (20 °C)
Nominal voltage, cable
300 V
Flame resistance
FT4
Other resistance
UV resistant
Ambient temperature (operation)
-30 °C - 105 °C (cable, fixed installation)
Ambient temperature (operation)
-5 °C - 105 °C (cable, flexible installation)

Gray, highly flexible PUR [800]

Note
Due to the extremely robust outer sheath, this cable should only be stripped in 5 cm increments.
Cable type
Gray, highly flexible PUR
Cable type (abbreviation)
800
Cable abbreviation
LiF9Y11Y
UL AWM style
20549
Conductor cross section
4x 0.25 mm² (Signal line)
AWG signal line
24
Conductor structure signal line
32x 0.10 mm
Core diameter including insulation
1.15 mm ±0.05 mm (Signal line)
Wire colors
brown, white, blue, black
Overall twist
4 wires, twisted
External sheath, color
gray RAL 7001
External cable diameter D
4.5 mm ±0.2 mm
Minimum bending radius, fixed installation
4 x D
Minimum bending radius, flexible installation
7.5 x D
Number of bending cycles
10000000
Minimum bending radius, drag chain applications
7,5 x D
Traversing path
5 m
Traversing rate
3.3 m/s
Acceleration
5 m/s²
Number of bending cycles
15000000
Bending radius
50 mm
Traversing path
0.9 m
Traversing rate
5 m/s
Acceleration
30 m/s²
Torsion force
± 360 °/m (1 000 000 torsion cycles)
Cable weight
27.1 kg/km
Outer sheath, material
PUR
Material conductor insulation
PP
Conductor material
Bare Cu litz wires
Insulation resistance
≥ 20 MΩ*km
Conductor resistance
approx. 76 Ω/km
Nominal voltage, cable
300 V
Test voltage, cable
1200 V
Special properties
Cable jacket is welding spark-resistant, recyclable, matt, low-adhesion, abrasion-resistant, flame-retardant, and self-extinguishing
Special properties
Free from silicone and cadmium
Special properties
Free of substances which would hinder coating with paint or varnish
Flame resistance
in accordance with UL 758/1581 FT2
Halogen-free
in accordance with DIN VDE 0472 part 815
Resistance to oil
in accordance with DIN EN 60811-2-1
Other resistance
Highly resistant to acids, alkaline solutions and solvents
Other resistance
Silicone-free
Ambient temperature (operation)
-40 °C - 80 °C (cable, fixed installation)
Ambient temperature (operation)
-25 °C - 80 °C (cable, flexible installation)

PUR halogen-free yellow [240]

Cable type
PUR halogen-free yellow
Cable type (abbreviation)
240
Cable abbreviation
Li9Y11Y
UL AWM style
20549
Conductor cross section
4x 0.25 mm² (Signal line)
AWG signal line
24
Conductor structure signal line
32x 0.10 mm
Core diameter including insulation
1.17 mm ±0.02 mm
Thickness, insulation
≥ 0.21 mm
Wire colors
brown, white, blue, black
Overall twist
4 wires, twisted
Length of twist, overall twist
45 mm
External sheath, color
yellow
Outer sheath thickness
approx. 0.75 mm
External cable diameter D
4.4 mm ±0.15 mm
Minimum bending radius, fixed installation
5 x D
Minimum bending radius, flexible installation
10 x D
Number of bending cycles
4000000
Minimum bending radius, drag chain applications
10 x D
Traversing path
10 m
Traversing rate
3 m/s
Acceleration
10 m/s²
Cable weight
25 kg/km
Outer sheath, material
PUR
Material conductor insulation
PP
Conductor material
Bare Cu litz wires
Insulation resistance
≥ 1 GΩ*km (at 20 °C)
Conductor resistance
78 Ω/km (at 20 °C)
Nominal voltage, cable
≤ 300 V AC
Test voltage, cable
≥ 3000 V AC (Spark test)
Flame resistance
in accordance with UL 758/1581 FT2
Halogen-free
in accordance with DIN VDE 0472 part 815
Halogen-free
According to EN 50267-2-1
Resistance to oil
According to DIN EN 60811-2-1, 168 h at 100°C
Resistance to oil
According to UL 758, 168 h at 60°C
Other resistance
hydrolysis and microbe resistant
Other resistance
Resistant to salt water
Other resistance
abrasion-resistant
Other resistance
Low adhesion
Ambient temperature (operation)
-40 °C - 80 °C (cable, fixed installation)
Ambient temperature (operation)
-25 °C - 80 °C (cable, flexible installation)

Dimensions

Length of cable
Free input (0.2 - 40.0 m)

Black PVC 105°C [535]

Cable type
Black PVC 105°C
Cable type (abbreviation)
535
UL AWM style
2517 (105 °C / 300 V)
AWG signal line
24
Conductor structure signal line
32x 1.10 mm
Core diameter including insulation
1.12 mm ±0.03 mm
Wire colors
brown, blue, black, white
Overall twist
4 wires, twisted
External sheath, color
black
External cable diameter D
4.4 mm ±0.2 mm
Minimum bending radius, flexible installation
8 x D
Cable weight
25 kg/km
Outer sheath, material
PVC
Material conductor insulation
PVC
Conductor material
Tin-plated Cu litz wires
Nominal voltage, cable
300 V
Flame resistance
FT4
Other resistance
UV resistant
Ambient temperature (operation)
-30 °C - 105 °C (cable, fixed installation)

Material

Flammability rating according to UL 94
HB
Contact material
CuSn
Contact surface material
Ni/Au
Contact carrier material
TPU GF
Material of grip body
TPU, hardly inflammable, self-extinguishing
Material, knurls
Zinc die-cast, nickel-plated
Sealing material
NBR

PUR halogen-free black [PUR]

Cable type
PUR halogen-free black
Cable type (abbreviation)
PUR
Cable abbreviation
Li9Y11Y-HF
UL AWM style
20549 / 10493 (80°C/300 V)
Conductor cross section
4x 0.25 mm² (Signal line)
AWG signal line
24
Conductor structure signal line
32x 0.10 mm
Core diameter including insulation
1.17 mm ±0.02 mm (Signal line)
Thickness, insulation
≥ 0.21 mm (Core insulation)
Thickness, insulation
approx. 0.5 mm (Outer cable sheath)
Wire colors
brown, white, blue, black
Overall twist
4 wires, twisted
External sheath, color
black-gray RAL 7021
External cable diameter D
3.95 mm ±0.15 mm
Smallest bending radius, fixed installation
20 mm
Smallest bending radius, movable installation
40 mm
Number of bending cycles
10000000
Bending radius
44 mm
Traversing path
10 m
Traversing rate
3 m/s
Acceleration
5 m/s²
Cable weight
23 kg/km
Outer sheath, material
PUR
Material conductor insulation
PP
Conductor material
Bare Cu litz wires
Insulation resistance
≥ 100 GΩ*km (at 20 °C)
Conductor resistance
max. 78 Ω/km (at 20 °C)
Nominal voltage, cable
≤ 300 V
Test voltage, cable
≥ 3000 V
Special properties
Flexible cable conduit capable
Special properties
Silicone-free
Special properties
Free of substances which would hinder coating with paint or varnish
Flame resistance
in accordance with UL 758/1581 FT2
Flame resistance
DIN EN 60332-2-2 (20 s)
Halogen-free
in accordance with DIN VDE 0472 part 815
Resistance to oil
in accordance with DIN EN 60811-2-1
Other resistance
Highly resistant to acids, alkaline solutions and solvents
Other resistance
hydrolysis and microbe resistant
Other resistance
partly UV-resistant in accordance with DIN EN ISO 4892-2-A
Ambient temperature (operation)
-40 °C - 80 °C (cable, fixed installation)
Ambient temperature (operation)
-25 °C - 80 °C (cable, flexible installation)

Ambient conditions

Ambient temperature (operation)
-25 °C - 90 °C (Plug / socket)
Degree of protection
IP65
Degree of protection
IP67
Degree of protection
IP68

Line characteristics

Note
This item is a sensor/actuator cable with a freely selectable cable type. The technical data for all possible cable types is listed in the table below.

Environmental Product Compliance

China RoHS
Environmentally Friendly Use Period = 50 years
China RoHS
For details about hazardous substances go to tab 'Downloads', Category 'Manufacturer's declaration'

Standards and Regulations

Standards/specifications
M8 connector IEC 61076-2-104
Flammability rating according to UL 94
HB