PUR halogen-free gray [280]

Cable type
PUR halogen-free gray
Cable type (abbreviation)
280
Cable abbreviation
Li9Y11Y-HF
UL AWM style
20549
Conductor cross section
3x 0.5 mm² (Signal line)
AWG signal line
20
Conductor structure signal line
28x 0.15 mm
Core diameter including insulation
1.5 mm ±0.05 mm (Signal line)
Wire colors
black 1, black 2, green/yellow
Overall twist
Wires twisted in layers
External sheath, color
gray RAL 7001
External cable diameter D
4.5 mm ±0.2 mm
Smallest bending radius, fixed installation
22.5 mm
Number of bending cycles
15000000
Bending radius
50 mm
Traversing path
0.9 m
Traversing rate
5 m/s
Acceleration
30 m/s²
Outer sheath, material
PUR
Material conductor insulation
PP
Conductor material
Bare Cu litz wires
Insulation resistance
≥ 20 MΩ*km
Conductor resistance
39 Ω/km (at 20 °C)
Nominal voltage, cable
300 V
Test voltage, cable
1200 V
Flame resistance
according to DIN VDE 0482
Flame resistance
According to DIN EN 50265-2-1
Resistance to oil
largely oil-resistant
Ambient temperature (operation)
-40 °C - 80 °C (cable, fixed installation)
Ambient temperature (operation)
-20 °C - 80 °C (cable, flexible installation)

PVC black [PVC]

Cable type
PVC black
Cable type (abbreviation)
PVC
Cable abbreviation
LiYY
UL AWM style
2464
Conductor cross section
3x 0.5 mm²
AWG signal line
20
Conductor structure signal line
16x 0.20 mm
Core diameter including insulation
1.5 mm ±0.05 mm
Wire colors
black 1, black 2, green/yellow
Overall twist
3 wires, twisted
External sheath, color
black RAL 9005
External cable diameter D
4.8 mm ±0.2 mm
Minimum bending radius, fixed installation
5 x D
Outer sheath, material
PVC
Material conductor insulation
PVC
Conductor material
Bare Cu litz wires
Insulation resistance
≥ 20 MΩ*km
Conductor resistance
39 Ω/km (at 20 °C)
Nominal voltage, cable
300 V
Test voltage, cable
1200 V
Flame resistance
DIN VDE 0482
Flame resistance
DIN EN 50265-2-1
Resistance to oil
largely oil-resistant
Ambient temperature (operation)
-40 °C - 80 °C (cable, fixed installation)
Ambient temperature (operation)
-5 °C - 80 °C (cable, flexible installation)

PUR halogen-free yellow [240]

Cable type
PUR halogen-free yellow
Cable type (abbreviation)
240
Cable abbreviation
Li9Y11Y
UL AWM style
20549 (80°C/300 V)
Conductor cross section
3x 0.5 mm²
AWG signal line
20
Conductor structure signal line
28x 0.15 mm
Core diameter including insulation
1.46 mm ±0.02 mm
Thickness, insulation
≥ 0.21 mm
Wire colors
black 1, black 2, green/yellow
Overall twist
3 wires, twisted
External sheath, color
yellow
Outer sheath thickness
approx. 0.6 mm
External cable diameter D
4.5 mm ±0.15 mm
Cable weight
30 kg/km
Outer sheath, material
PUR
Material conductor insulation
PP
Conductor material
Bare Cu litz wires
Insulation resistance
≥ 10 GΩ*km
Conductor resistance
≤ 39 Ω/km
Nominal voltage, cable
≤ 300 V
Test voltage, cable
≥ 3000 V
Flame resistance
in accordance with DIN UL-Style 20549
Halogen-free
in accordance with DIN VDE 0472 part 815
Ambient temperature (operation)
-15 °C - 80 °C (cable, fixed installation)

PUR irradiated halogen-free orange [150]

Cable type
PUR irradiated halogen-free orange
Cable type (abbreviation)
150
Cable abbreviation
Li12Y11X
Conductor cross section
3x 0.5 mm² (Signal line)
AWG signal line
20
Conductor structure signal line
28x 0.15 mm
Core diameter including insulation
1.46 mm ±0.02 mm (Signal line)
Thickness, insulation
≥ 0.21 mm (Core insulation)
Thickness, insulation
approx. 0.6 mm (Outer cable sheath)
Wire colors
black 1, black 2, green/yellow
Overall twist
3 wires, twisted
External sheath, color
orange RAL 2003
External cable diameter D
4.5 mm ±0.15 mm
Number of bending cycles
5000000
Bending radius
45 mm
Traversing path
10 m
Traversing rate
3 m/s
Cable weight
31 kg/km
Outer sheath, material
PUR
Material conductor insulation
TPE-E
Conductor material
Bare Cu litz wires
Insulation resistance
≥ 100 MΩ*km (at 20 °C)
Conductor resistance
max. 39 Ω/km (at 20 °C)
Nominal voltage, cable
≤ 300 V
Test voltage, cable
≥ 3000 V
Special properties
Silicone-free
Special properties
Irradiated
Flame resistance
in accordance with DIN UL-Style 20549
Halogen-free
in accordance with DIN VDE 0472 part 815
Ambient temperature (operation)
-25 °C - 80 °C (cable, fixed installation)
Ambient temperature (operation)
-5 °C - 80 °C (cable, flexible installation)

PUR black [121]

Cable type
PUR black
Cable type (abbreviation)
121
Cable abbreviation
Li9Y11Y
UL AWM style
20549
Conductor cross section
3x 1 mm²
AWG signal line
17
Conductor structure signal line
32x 0.20 mm
Core diameter including insulation
2.1 mm ±0.05 mm
Wire colors
black 1, black 2, green/yellow
Overall twist
3 wires, twisted
External sheath, color
black RAL 9005
External cable diameter D
6 mm ±0.2 mm
Minimum bending radius, flexible installation
7.5 x D
Number of bending cycles
3000000
Traversing rate
2.5 m/s
Acceleration
10 m/s²
Outer sheath, material
PUR
Material conductor insulation
PP
Conductor material
Bare Cu litz wires
Insulation resistance
≥ 20 MΩ*km
Conductor resistance
19.5 Ω/km (at 20 °C)
Nominal voltage, cable
300 V
Test voltage, cable
1200 V
Special properties
highly flexible
Flame resistance
DIN VDE 0482
Flame resistance
DIN EN 50265-2-1
Resistance to oil
largely oil-resistant
Other resistance
Low adhesion
Ambient temperature (operation)
-40 °C - 80 °C (cable, fixed installation)
Ambient temperature (operation)
-20 °C - 80 °C (cable, flexible installation)

Dimensions

Length of cable
Free input (0.2 - 40.0 m)
Stripping length of the free conductor end
50 mm

PVC, 0.75 mm², black [534]

Conductor cross section
3x 0.75 mm² (Signal line)
AWG signal line
18
Conductor structure signal line
24x 0.20 mm
Core diameter including insulation
1.7 mm ±0.1 mm
Wire colors
black 1, black 2, green/yellow
Overall twist
3 wires, twisted
External sheath, color
black
External cable diameter D
5.3 mm ±0.2 mm
Minimum bending radius, fixed installation
5 x D
Outer sheath, material
PVC
Material conductor insulation
PVC
Conductor material
Bare Cu litz wires
Insulation resistance
min. 20 MΩ*km (at 20 °C)
Conductor resistance
26 Ω/km (at 20 °C)
Nominal voltage, cable
300 V
Test voltage, cable
1200 V
Flame resistance
DIN VDE 0482
Flame resistance
DIN EN 50265-2-1
Flame resistance
in acc. to UL VW1
Resistance to oil
in accordance with DIN EN 60811-2-1
Ambient temperature (operation)
-40 °C - 80 °C (cable, fixed installation)
Ambient temperature (operation)
-5 °C - 80 °C (cable, flexible installation)

Material

Flammability rating according to UL 94
HB
Contact material
CuSn
Contact surface material
Ni/Au
Contact carrier material
TPU GF
Material of grip body
TPU, hardly inflammable, self-extinguishing
Material, knurls
Zinc die-cast, nickel-plated
Sealing material
NBR

PUR/PVC, 0.75 mm², black [116]

Cable type
PUR/PVC, 0.75 mm², black
Cable type (abbreviation)
116
Cable abbreviation
LiYY11Y
UL AWM style
20549
Conductor cross section
3x 0.75 mm²
AWG signal line
18
Conductor structure signal line
24x 0.20 mm
Core diameter including insulation
1.7 mm ±0.05 mm
Wire colors
black 1, black 2, green/yellow
Overall twist
3 wires, twisted
External sheath, color
black RAL 9005
External cable diameter D
5.8 mm ±0.2 mm
Minimum bending radius, flexible installation
10 x D
Number of bending cycles
1000000
Traversing rate
2 m/s
Acceleration
2.5 m/s²
Outer sheath, material
PUR
Material, inner sheath
PVC
Material conductor insulation
PVC
Conductor material
Bare Cu litz wires
Insulation resistance
≥ 20 MΩ*km
Conductor resistance
26 Ω/km (at 20 °C)
Nominal voltage, cable
300 V
Test voltage, cable
1200 V
Special properties
flexible
Flame resistance
DIN VDE 0482
Flame resistance
DIN EN 50265-2-1
Flame resistance
in acc. with UL FT-2
Other resistance
Low adhesion
Ambient temperature (operation)
-40 °C - 80 °C (cable, fixed installation)
Ambient temperature (operation)
-5 °C - 80 °C (cable, flexible installation)

PUR halogen-free black [PUR]

Cable type
PUR halogen-free black
Cable type (abbreviation)
PUR
Cable abbreviation
Li9Y11Y-HF
UL AWM style
20549
Conductor cross section
3x 0.5 mm²
AWG signal line
20
Conductor structure signal line
28x 0.15 mm
Core diameter including insulation
1.5 mm ±0.05 mm (Signal line)
Wire colors
black 1, black 2, green/yellow
Overall twist
3 wires, twisted
External sheath, color
black-gray RAL 7021
External cable diameter D
4.5 mm ±0.2 mm
Smallest bending radius, fixed installation
22.5 mm
Number of bending cycles
15000000
Bending radius
50 mm
Traversing path
0.9 m
Traversing rate
5 m/s
Acceleration
30 m/s²
Outer sheath, material
PUR
Material conductor insulation
PP
Conductor material
Bare Cu litz wires
Insulation resistance
min. 20 MΩ*km
Conductor resistance
39 Ω/km (at 20 °C)
Nominal voltage, cable
≤ 300 V
Test voltage, cable
≥ 1200 V
Flame resistance
according to DIN VDE 0482
Flame resistance
According to DIN EN 50265-2-1
Halogen-free
in accordance with DIN VDE 0472 part 815
Other resistance
largely oil-resistant
Other resistance
partly UV-resistant in accordance with DIN EN ISO 4892-2-A
Ambient temperature (operation)
-40 °C - 80 °C (cable, fixed installation)
Ambient temperature (operation)
-20 °C - 80 °C (cable, flexible installation)

PUR, halogen-free, highly stranded, resistant to welding sparks, gray [800]

Note
Due to the extremely robust outer sheath, this cable should only be stripped in 5 cm increments.
Cable abbreviation
LiF9Y11Y
UL AWM style
20549
Conductor cross section
3x 0.5 mm² (Signal line)
AWG signal line
20
Conductor structure signal line
28x 0.15 mm
Core diameter including insulation
1.5 mm ±0.05 mm (Signal line)
Wire colors
black 1, black 2, green/yellow
Overall twist
Wires twisted in layers
External sheath, color
gray RAL 7001
External cable diameter D
4.5 mm ±0.2 mm
Minimum bending radius, fixed installation
5 x D
Minimum bending radius, flexible installation
5 x D
Number of bending cycles
15000000
Bending radius
50 mm
Traversing path
0.9 m
Traversing rate
5 m/s
Acceleration
30 m/s²
Torsion force
± 360 °/m
Cable weight
31 kg/km
Outer sheath, material
PUR
Material conductor insulation
PP
Conductor material
Bare Cu litz wires
Insulation resistance
≥ 20 MΩ*km
Conductor resistance
39 Ω/km (at 20 °C)
Nominal voltage, cable
300 V
Test voltage, cable
1200 V
Special properties
Cable jacket is welding spark-resistant, recyclable, matt, low-adhesion, abrasion-resistant, flame-retardant, and self-extinguishing
Special properties
Free from silicone and cadmium
Special properties
Free of substances which would hinder coating with paint or varnish
Flame resistance
in accordance with UL 758/1581 FT2
Halogen-free
The cable is halogen-free
Resistance to oil
in accordance with DIN EN 60811-2-1
Other resistance
Highly resistant to acids, alkaline solutions and solvents
Ambient temperature (operation)
-40 °C - 80 °C (cable, fixed installation)
Ambient temperature (operation)
-25 °C - 80 °C (cable, flexible installation)

PVC gray [500]

Cable type
PVC gray
Cable type (abbreviation)
500
Cable abbreviation
LiYY
Conductor cross section
3x 0.5 mm² (Signal line)
AWG signal line
20
Conductor structure signal line
16x 0.20 mm
Core diameter including insulation
1.5 mm ±0.05 mm (Signal line)
Wire colors
black 1, black 2, green/yellow
Overall twist
Wires twisted in layers
External sheath, color
gray RAL 7001
External cable diameter D
4.8 mm ±0.2 mm
Smallest bending radius, fixed installation
24 mm
Outer sheath, material
PVC
Material conductor insulation
PVC
Conductor material
Bare Cu litz wires
Insulation resistance
min. 20 MΩ*km
Conductor resistance
39 Ω/km (at 20 °C)
Nominal voltage, cable
300 V
Test voltage, cable
1200 V
Flame resistance
DIN EN 50265-2-1
Resistance to oil
largely oil-resistant
Ambient temperature (operation)
-40 °C - 80 °C (cable, fixed installation)
Ambient temperature (operation)
-5 °C - 80 °C (cable, flexible installation)

Ambient conditions

Ambient temperature (operation)
-25 °C - 90 °C (Plug / socket)
Degree of protection
IP65
Degree of protection
IP67
Degree of protection
IP68

Line characteristics

Note
This item is a sensor/actuator cable with a freely selectable cable type. The technical data for all possible cable types is listed in the table below.

Environmental Product Compliance

China RoHS
Environmentally friendly use period: unlimited = EFUP-e
China RoHS
No hazardous substances above threshold values

PUR/PVC 0.75 mm² gray [117]

Cable abbreviation
LiYY11Y
UL AWM style
20549
Conductor cross section
3x 0.75 mm² (Signal line)
AWG signal line
18
Conductor structure signal line
24x 0.20 mm
Core diameter including insulation
1.7 mm ±0.05 mm (Signal line)
Wire colors
black 1, black 2, green/yellow
Overall twist
Wires twisted in layers
External sheath, color
gray RAL 7001
External cable diameter D
5.8 mm ±0.2 mm
Smallest bending radius, fixed installation
29 mm
Smallest bending radius, movable installation
58 mm
Number of bending cycles
1000000
Traversing rate
2 m/s
Acceleration
2.5 m/s²
Outer sheath, material
PUR
Material, inner sheath
PVC
Material conductor insulation
PVC
Conductor material
Bare Cu litz wires
Insulation resistance
≥ 20 MΩ*km
Conductor resistance
26 Ω/km (at 20 °C)
Nominal voltage, cable
300 V
Test voltage, cable
1200 V
Flame resistance
according to DIN VDE 0482
Flame resistance
According to DIN EN 50265-2-1
Flame resistance
in acc. with UL FT-2
Ambient temperature (operation)
-40 °C - 80 °C (cable, fixed installation)
Ambient temperature (operation)
-5 °C - 80 °C (cable, flexible installation)

Standards and Regulations

Standards/specifications
M12 connector IEC 61076-2-101
Flammability rating according to UL 94
HB