Network cable - NBC-MS SCO-IE/.../... - 1408682
1408682
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

Ethernet flexible CAT5, 4-pair [94B]

Cable type
Ethernet flexible CAT5, 4-pair
Cable type (abbreviation)
94B
UL AWM style
20963 (80°C/30 V)
Signal type/category
Ethernet CAT5 (IEC 11801), 1 Gbps
Cable structure
4x2xAWG26/7; SF/UTP
Conductor cross section
4x 2x 0.14 mm²
AWG signal line
26
Conductor structure signal line
7x 0.16 mm
Core diameter including insulation
0.96 mm
Wire colors
white/blue-blue, white/orange-orange, white/green-green, white/brown-brown
Twisted pairs
2 cores to the pair
Overall twist
4 pairs for core
Shielding
Aluminum-coated foil, tinned copper braided shield
Optical shield covering
70 %
External sheath, color
water blue RAL 5021
Outer sheath thickness
1.05 mm
External cable diameter D
6.4 mm ±0.2 mm
Minimum bending radius, fixed installation
4 x D
Minimum bending radius, flexible installation
8 x D
Tensile strength GRP
≤ 100 N
Cable weight
47 kg/km
Outer sheath, material
PUR
Material conductor insulation
Foamed PE
Conductor material
Bare Cu litz wires
Insulation resistance
≥ 500 MΩ*km
Loop resistance
≤ 290.00 Ω/km
Cable capacity
48 nF/km (at 1 kHz)
Wave impedance
100 Ω ±5 Ω (at 100 MHz)
Near end crosstalk attenuation (NEXT)
71.3 dB (with 1 MHz)
Near end crosstalk attenuation (NEXT)
62.3 dB (at 4 МHz)
Near end crosstalk attenuation (NEXT)
56.3 dB (at 10 MHz)
Near end crosstalk attenuation (NEXT)
53.2 dB (at 16 MHz)
Near end crosstalk attenuation (NEXT)
51.8 dB (at 20 МHz)
Near end crosstalk attenuation (NEXT)
48.9 dB (at 31.25 МHz)
Near end crosstalk attenuation (NEXT)
44.4 dB (at 62.5 МHz)
Near end crosstalk attenuation (NEXT)
41.3 dB (at 100 MHz)
Power-summated near end crosstalk attenuation (PSNEXT)
62.3 dB (with 1 MHz)
Power-summated near end crosstalk attenuation (PSNEXT)
53.3 dB (at 4 МHz)
Power-summated near end crosstalk attenuation (PSNEXT)
47.3 dB (at 10 MHz)
Power-summated near end crosstalk attenuation (PSNEXT)
44.2 dB (at 16 MHz)
Power-summated near end crosstalk attenuation (PSNEXT)
42.8 dB (at 20 МHz)
Power-summated near end crosstalk attenuation (PSNEXT)
39.9 dB (at 31.25 МHz)
Power-summated near end crosstalk attenuation (PSNEXT)
35.4 dB (at 62.5 МHz)
Power-summated near end crosstalk attenuation (PSNEXT)
32.3 dB (at 100 MHz)
Attenuation
3.2 dB (with 1 MHz)
Attenuation
6 dB (at 4 МHz)
Attenuation
9.5 dB (at 10 MHz)
Attenuation
12.1 dB (at 16 MHz)
Attenuation
13.6 dB (at 20 МHz)
Attenuation
17.1 dB (at 31.25 МHz)
Attenuation
24.8 dB (at 62.5 МHz)
Attenuation
32 dB (at 100 MHz)
Return loss (RL)
23 dB (at 4 МHz)
Return loss (RL)
24.1 dB (at 8 МHz)
Return loss (RL)
25 dB (at 10 MHz)
Return loss (RL)
25 dB (at 16 MHz)
Return loss (RL)
25 dB (at 20 МHz)
Return loss (RL)
23.6 dB (at 31.25 МHz)
Return loss (RL)
21.5 dB (at 62.5 МHz)
Return loss (RL)
20.1 dB (at 100 MHz)
Signal runtime
5.3 ns/m
Coupling resistance
≤ 100.00 mΩ/m (at 10 MHz)
Nominal voltage, cable
≤ 100 V
Test voltage Core/Core
700 V (50 Hz, 1 min.)
Test voltage Core/Shield
700 V (50 Hz, 1 min.)
Flame resistance
according to IEC 60332-1-2
Halogen-free
according to IEC 60754-1
Resistance to oil
according to EN 60811-2-1
Ambient temperature (operation)
-40 °C - 80 °C (cable, fixed installation)
Ambient temperature (operation)
-20 °C - 80 °C (cable, flexible installation)
Ambient temperature (installation)
-20 °C - 80 °C
Ambient temperature (storage/transport)
-20 °C - 80 °C

Dimensions

Length of cable
Free input (0.2 - 40.0 m)

General data

Note
Further products with fixed cable length can be found in the accessories section
Rated current at 40°C
2 A
Rated voltage
48 V AC
Rated voltage
60 V DC
Number of positions
8
Signal type/category
Ethernet CAT5 (on the basis of IEC 11801), 1 Gbps
Standards/regulations
M12 connector IEC 61076-2-101
Contact material
CuSn
Contact carrier material
TPU GF
Contact surface material
Ni/Au
Degree of protection
IP65/IP67

Ethernet drag chain CAT5, 4-pair [94C]

Cable type
Ethernet drag chain CAT5, 4-pair
Cable type (abbreviation)
94C
UL AWM style
20963 (80°C/30 V)
Signal type/category
Ethernet CAT5 (IEC 11801), 1 Gbps
Cable structure
4x2xAWG26/19; S/UTP
Conductor cross section
4x 2x 0.14 mm²
AWG signal line
26
Conductor structure signal line
19x 0.10 mm
Core diameter including insulation
1 mm
Wire colors
white/blue-blue, white/orange-orange, white/green-green, white/brown-brown
Twisted pairs
2 cores to the pair
Overall twist
Four pairs and four fillers to the core
Shielding
Tinned copper braided shield
Optical shield covering
90 %
External sheath, color
water blue RAL 5021
Outer sheath thickness
0.85 mm
External cable diameter D
6.9 mm +0.1 mm - 0.2 mm
Minimum bending radius, fixed installation
4 x D
Minimum bending radius, flexible installation
8 x D
Number of bending cycles
5000000
Minimum bending radius, drag chain applications
7,5 x D
Traversing rate
3 m/s
Acceleration
5 m/s²
Tensile strength GRP
≤ 100 N
Cable weight
57 kg/km
Outer sheath, material
PUR
Material conductor insulation
PP
Conductor material
Bare Cu litz wires
Insulation resistance
≥ 500 MΩ*km
Loop resistance
≤ 290.00 Ω/km
Cable capacity
approx. 50 nF/km (at 1 kHz)
Wave impedance
100 Ω ±5 Ω (at 100 MHz)
Near end crosstalk attenuation (NEXT)
65.3 dB (with 1 MHz)
Near end crosstalk attenuation (NEXT)
56.3 dB (at 4 МHz)
Near end crosstalk attenuation (NEXT)
50.3 dB (at 10 MHz)
Near end crosstalk attenuation (NEXT)
47.2 dB (at 16 MHz)
Near end crosstalk attenuation (NEXT)
45.8 dB (at 20 МHz)
Near end crosstalk attenuation (NEXT)
42.9 dB (at 31.25 МHz)
Near end crosstalk attenuation (NEXT)
38.4 dB (at 62.5 МHz)
Near end crosstalk attenuation (NEXT)
35.3 dB (at 100 MHz)
Power-summated near end crosstalk attenuation (PSNEXT)
62.3 dB (with 1 MHz)
Power-summated near end crosstalk attenuation (PSNEXT)
53.3 dB (at 4 МHz)
Power-summated near end crosstalk attenuation (PSNEXT)
47.3 dB (at 10 MHz)
Power-summated near end crosstalk attenuation (PSNEXT)
44.2 dB (at 16 MHz)
Power-summated near end crosstalk attenuation (PSNEXT)
42.8 dB (at 20 МHz)
Power-summated near end crosstalk attenuation (PSNEXT)
39.9 dB (at 31.25 МHz)
Power-summated near end crosstalk attenuation (PSNEXT)
35.4 dB (at 62.5 МHz)
Power-summated near end crosstalk attenuation (PSNEXT)
32.3 dB (at 100 MHz)
Attenuation
3.2 dB (with 1 MHz)
Attenuation
6 dB (at 4 МHz)
Attenuation
9.5 dB (at 10 MHz)
Attenuation
12.1 dB (at 16 MHz)
Attenuation
13.6 dB (at 20 МHz)
Attenuation
17.1 dB (at 31.25 МHz)
Attenuation
24.8 dB (at 62.5 МHz)
Attenuation
32 dB (at 100 MHz)
Return loss (RL)
23 dB (at 4 МHz)
Return loss (RL)
24.1 dB (at 8 МHz)
Return loss (RL)
25 dB (at 10 MHz)
Return loss (RL)
25 dB (at 16 MHz)
Return loss (RL)
25 dB (at 20 МHz)
Return loss (RL)
23.6 dB (at 31.25 МHz)
Return loss (RL)
21.5 dB (at 62.5 МHz)
Return loss (RL)
20.1 dB (at 100 MHz)
Signal runtime
5.3 ns/m
Coupling resistance
≤ 100.00 mΩ/m (at 10 MHz)
Nominal voltage, cable
≤ 100 V
Test voltage Core/Core
700 V (50 Hz, 1 min.)
Test voltage Core/Shield
700 V (50 Hz, 1 min.)
Flame resistance
according to IEC 60332-1-2
Halogen-free
according to IEC 60754-1
Resistance to oil
according to EN 60811-2-1
Ambient temperature (operation)
-40 °C - 80 °C (cable, fixed installation)
Ambient temperature (operation)
-20 °C - 80 °C (cable, flexible installation)
Ambient temperature (installation)
-20 °C - 80 °C
Ambient temperature (storage/transport)
-20 °C - 80 °C

Ambient conditions

Degree of protection
IP65
Degree of protection
IP67
Ambient temperature (operation)
-25 °C - 90 °C (M12 connector)

Line characteristics

Note
This item is a network cable with a freely selectable cable type. The technical data for all possible cable types is listed in the table below.

Environmental Product Compliance

REACh SVHC
Lead 7439-92-1
China RoHS
Environmentally Friendly Use Period = 50 years
China RoHS
For details about hazardous substances go to tab 'Downloads', Category 'Manufacturer's declaration'

Characteristics head 2

Head type
free cable end
Color
black

Standards and Regulations

Standards/specifications
M12 connector IEC 61076-2-101

Characteristics head 1

Head type
Plug straight M12 SPEEDCON / IP67
No. of positions (pin connector pattern)
8
Coding
A (Standard)
Color
black
Material (component)
CuZn (Contact)
Material (component)
Ni/Au (Contact surface)
Material (component)
TPU GF (Contact carriers)
Material (component)
TPU, hardly inflammable, self-extinguishing (Grip)
Material (component)
Zinc die-cast, nickel-plated (Screw connection)
Insulation resistance
≥ 100 MΩ
Insertion/withdrawal cycles
≥ 100
Torque
0.4 Nm
Ambient temperature (operation)
-25 °C - 90 °C
Shielded
yes
Type type, plug side
Plug straight
Type type, socket side
free cable end

Other Categories