Request a Quote and we will send you information on availability and price.

Dimensions

Length of cable
Free input (0.2 - 40.0 m)

Material

Flammability rating according to UL 94
V0
Contact material
CuSn
Contact surface material
Ni/Au
Contact carrier material
PA 6.6
Material of grip body
PA 6.6
Material, knurls
Zinc die-cast, nickel-plated
Standards/regulations
PA 6.6: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DIN EN 45545-2 (Risk level HL1 - HL3)

Ambient conditions

Ambient temperature (operation)
-40 °C - 85 °C (Plug / socket)
Degree of protection
IP65

Line characteristics

Note
This item is a sensor/actuator cable with a freely selectable cable type. The technical data for all possible cable types is listed in the table below.

Databus MVB [91R]

Cable type
Databus MVB
Cable type (abbreviation)
91R
Cable structure
2 x 0.5 mm² + 1 x 0.5 mm²
Conductor cross section
2x 0.5 mm² (Multifunction Vehicle Bus)
Conductor cross section
1x 0.5 mm² (Additional wire)
AWG signal line
20
AWG power supply
20
Conductor structure signal line
19x 0.18 mm
Conductor structure, voltage supply
19x 0.18 mm
Core diameter including insulation
2.3 mm (Multifunction Vehicle Bus)
Core diameter including insulation
1.45 mm (Additional wire)
Wire colors
Blue-red, black
Twisted pairs
2 cores to the pair
Overall twist
1 pair and 1 core with filler litz wire, horizontally twisted
Shielding
Tinned copper braided shield
External sheath, color
black
External cable diameter D
6.8 mm ±0,3 mm
Minimum bending radius, fixed installation
3 x D
Minimum bending radius, flexible installation
5 x D
Cable weight
62 kg/km
Outer sheath, material
PE-X
Material conductor insulation
Foamed PE (Multifunction Vehicle Bus)
Material conductor insulation
PE-X (Additional wire)
Conductor material
Tin-plated Cu litz wires
Insulation resistance
> 100 MΩ*km (Multifunction Vehicle Bus)
Conductor resistance
≤ 40.1 Ω/km
Working capacitance
≤ 45 pF (f = 1 MHz)
Wave impedance
120 Ω ±12 Ω (f = 0.75 MHz - 3 MHz)
Shield attenuation
≤ 6.7 dB/km (f = 0.25 MHz)
Shield attenuation
≤ 1.35 dB/km (f = 1 MHz)
Shield attenuation
≤ 1.8 dB/km (f = 2 MHz)
Shield attenuation
≤ 2.3 dB/km (f = 3 MHz)
Coupling resistance
≤ 20.00 mΩ/m (f ≤ 20 MHz)
Nominal voltage, cable
300 V (Multifunction Vehicle Bus)
Nominal voltage, cable
300 V
Test voltage, cable
2000 V AC
Special properties
Fire protection in rail vehicles according to DIN 5510 Fire protection level 1, 2, 3, 4
Flame resistance
According to DIN EN 50265-2-1
Flame resistance
according to EN 50265-2-1
Flame resistance
according to IEC 60332-1
Halogen-free
According to EN 50267-2-1
Halogen-free
according to IEC 60754-1
Concentration of fumes
EN 50268-2
Concentration of fumes
according to IEC 61034-2
Fume corrosiveness
according to EN 50267-2-3
Fume corrosiveness
according to IEC 60754-2
Ambient temperature (operation)
-40 °C - 90 °C

Environmental Product Compliance

China RoHS
Environmentally Friendly Use Period = 50
China RoHS
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Shielded black RADOX<sup>®</sup> [28R]

Cable type
Shielded black RADOX®
Cable type (abbreviation)
28R
Conductor cross section
3x 0.5 mm²
AWG signal line
20
Conductor structure signal line
19x 0.18 mm
Core diameter including insulation
1.43 mm
Wire colors
White 1, white 2, white 3
Overall twist
3 wires, twisted
Shielding
Tinned copper braided shield
External sheath, color
black
External cable diameter D
5.3 mm ±0,3 mm
Minimum bending radius, fixed installation
3 x D
Minimum bending radius, flexible installation
4 x D
Cable weight
51 kg/km
Outer sheath, material
PE-X
Material conductor insulation
PE-X
Conductor material
Tin-plated Cu litz wires
Conductor resistance
≤ 40.1 Ω/km
Nominal voltage, cable
600 V AC (Core-ground, U0)
Nominal voltage, cable
1000 V AC (Core-ground, U)
Nominal voltage, cable
≤ 720 V AC (core-ground)
Nominal voltage, cable
≤ 1200 V AC (Core-ground, Um)
Nominal voltage, cable
≤ 900 V DC (Core-ground, V0)
Nominal voltage, cable
≤ 1500 V DC (core-core)
Test voltage, cable
3500 V AC (50 Hz, 5 min.)
Test voltage, cable
8400 V DC (50 Hz, 5 min.)
Fire protection in rail vehicles
BS 6853 (Category Ia, Ib, II)
Fire protection in rail vehicles
GM/RT 2130 (Category Ia, Ib, II)
Fire protection in rail vehicles
EN 45545 (Risk level HL1 - HL3)
Fire protection in rail vehicles
DIN 5510 (Fire protection level 1, 2, 3, 4)
Fire protection in rail vehicles
NF F16-101 (Category A1, A2, B)
Fire protection in rail vehicles
NF F16-101 (Class C/F0)
Fire protection in rail vehicles
NFPA 130
Fire protection in rail vehicles
UNI CEI 11170 (Risk level LR1 - LR4)
Flame resistance
EN 60332-1-2
Flame resistance
EN 50266
Flame resistance
EN 50305, 9.1.2
Flame resistance
NF C32-070, 2.1
Flame resistance
NF C32-070, 2.2
Flame resistance
UL 1685, 12 (FT4)
Flame resistance
in accordance with ISO 6722-1 5.22 (UN ECE-R 118.01)
Halogen-free
According to EN 50267-2-1
Resistance to oil
according to IRM 902, 72 h at 100 °C
Other resistance
Resistance to fuels according to IRM 903, 168 h at 70 °C
Concentration of fumes
BS 6853 D.8.7
Concentration of fumes
EN 61034-2
Concentration of fumes
UL 1685, 12 (FT4)
Fume corrosiveness
EN 50267-2-2
Fume toxicity
BS 6853 B.1
Fume toxicity
EN 50305, 9.2
Ambient temperature (operation)
-50 °C - 120 °C (cable, fixed installation)
Ambient temperature (operation)
-25 °C - 90 °C (cable, flexible installation)

Standards and Regulations

Standard designation
M12 connector
Standards/regulations
IEC 61076-2-101
Standard designation
Shock, vibration
Standards/regulations
EN 50155
Flammability rating according to UL 94
V0