Sensor/actuator cable - SAC-4P-MS-FS SCO RAIL/.../... - 1412171
1412171
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

Dimensions

Length of cable
Free input (0.2 - 40.0 m)

RADOX<sup>®</sup> black shielded 0.75 mm² [29R]

Conductor cross section
4x 0.75 mm²
AWG signal line
18
Conductor structure signal line
19x 0.22 mm
Core diameter including insulation
1.63 mm
Wire colors
White 1, white 2, white 3, white 4
Overall twist
4 wires, twisted
Shielding
Tinned copper braided shield
External sheath, color
black
External cable diameter D
6 mm ±0.3 mm
Minimum bending radius, fixed installation
3 x D
Minimum bending radius, flexible installation
4 x D
Cable weight
72 kg/km
Outer sheath, material
PE-X
Material conductor insulation
PE-X
Conductor material
Tin-plated Cu litz wires
Conductor resistance
≤ 26.7 Ω/km
Nominal voltage, cable
600 V AC (Core-ground, U₀)
Nominal voltage, cable
1000 V AC (Core-ground, U)
Nominal voltage, cable
≤ 720 V AC (core-ground)
Nominal voltage, cable
≤ 1200 V AC (Core-ground, Um)
Nominal voltage, cable
≤ 900 V DC (Core-ground, V₀)
Nominal voltage, cable
≤ 1500 V DC (core-core)
Test voltage, cable
3500 V AC (50 Hz, 5 min.)
Test voltage, cable
8400 V DC (50 Hz, 5 min.)
Fire protection in rail vehicles
BS 6853 (Category Ia, Ib, II)
Fire protection in rail vehicles
GM/RT 2130 (Category Ia, Ib, II)
Fire protection in rail vehicles
EN 45545 (Risk level HL1 - HL3)
Fire protection in rail vehicles
DIN 5510 (Fire protection level 1, 2, 3, 4)
Fire protection in rail vehicles
NF F16-101 (Category A1, A2, B)
Fire protection in rail vehicles
NF F16-101 (Class C/F0)
Fire protection in rail vehicles
NFPA 130
Fire protection in rail vehicles
UNI CEI 11170 (Risk level LR1 - LR4)
Flame resistance
EN 60332-1-2
Flame resistance
EN 50266
Flame resistance
EN 50305, 9.1.2
Flame resistance
NF C32-070, 2.1
Flame resistance
NF C32-070, 2.2
Flame resistance
UL 1685, 12 (FT4)
Flame resistance
in accordance with ISO 6722-1 5.22 (UN ECE-R 118.01)
Halogen-free
According to EN 50267-2-1
Resistance to oil
according to IRM 902, 72 h at 100 °C
Other resistance
Resistance to fuels according to IRM 903, 168 h at 70 °C
Concentration of fumes
BS 6853 D.8.7
Concentration of fumes
EN 61034-2
Concentration of fumes
UL 1685, 12 (FT4)
Fume corrosiveness
EN 50267-2-2
Fume toxicity
BS 6853 B.1
Fume toxicity
EN 50305, 9.2
Ambient temperature (operation)
-50 °C - 120 °C (cable, fixed installation)
Ambient temperature (operation)
-25 °C - 90 °C (cable, flexible installation)

Material

Flammability rating according to UL 94
V0
Contact material
CuSn
Contact surface material
Ni/Au
Contact carrier material
PA 6.6
Material of grip body
PA 6.6
Material, knurls
Zinc die-cast, nickel-plated
Sealing material
NBR
Standards/regulations
PA 6.6: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DIN EN 45545-2 (Risk level HL1 - HL3)

RADOX<sup>®</sup> black Twisted-Pair [28T]

Cable type
RADOX® black Twisted-Pair
Cable type (abbreviation)
28T
Conductor cross section
2x 2x 0.5 mm²
AWG signal line
20
Conductor structure signal line
19x 0.18 mm
Core diameter including insulation
1.4 mm
Wire colors
white 1-white 2, white 3-white 4
Twisted pairs
2 cores to the pair
Overall twist
Two pairs with two fillers to the core
Shielding
Tinned copper braided shield
External sheath, color
black
External cable diameter D
7.2 mm ±0.3 mm
Minimum bending radius, fixed installation
3 x D
Minimum bending radius, flexible installation
4 x D
Cable weight
80 kg/km
Outer sheath, material
PE-X
Material conductor insulation
PE-X
Conductor material
Tin-plated Cu litz wires
Conductor resistance
≤ 40.1 Ω/km
Nominal voltage, cable
600 V AC (Core-ground, U₀)
Nominal voltage, cable
1000 V AC (Core-ground, U)
Nominal voltage, cable
≤ 720 V AC (core-ground)
Nominal voltage, cable
≤ 1200 V AC (Core-ground, Um)
Nominal voltage, cable
≤ 900 V DC (Core-ground, V₀)
Nominal voltage, cable
≤ 1500 V DC (core-core)
Test voltage, cable
3500 V AC (50 Hz, 5 min.)
Test voltage, cable
8400 V DC (50 Hz, 5 min.)
Fire protection in rail vehicles
BS 6853 (Category Ia, Ib, II)
Fire protection in rail vehicles
GM/RT 2130 (Category Ia, Ib, II)
Fire protection in rail vehicles
EN 45545 (Risk level HL1 - HL3)
Fire protection in rail vehicles
DIN 5510 (Fire protection level 1, 2, 3, 4)
Fire protection in rail vehicles
NF F16-101 (Category A1, A2, B)
Fire protection in rail vehicles
NF F16-101 (Class C/F0)
Fire protection in rail vehicles
NFPA 130
Fire protection in rail vehicles
UNI CEI 11170 (Risk level LR1 - LR4)
Flame resistance
EN 60332-1-2
Flame resistance
EN 50266
Flame resistance
EN 60332-3-25
Flame resistance
NF C32-070, 2.1
Flame resistance
NF C32-070, 2.2
Flame resistance
UL 1685, 12 (FT4)
Flame resistance
in accordance with ISO 6722-1 5.22 (UN ECE-R 118.01)
Halogen-free
According to EN 50267-2-1
Resistance to oil
according to IRM 902, 72 h at 100 °C
Other resistance
Resistance to fuels according to IRM 903, 168 h at 70 °C
Concentration of fumes
BS 6853 D.8.7
Concentration of fumes
EN 61034-2
Concentration of fumes
UL 1685, 12 (FT4)
Fume corrosiveness
EN 50267-2-2
Fume toxicity
BS 6853 B.1
Fume toxicity
EN 50305, 9.2
Ambient temperature (operation)
-50 °C - 120 °C (cable, fixed installation)
Ambient temperature (operation)
-25 °C - 90 °C (cable, flexible installation)

Ambient conditions

Ambient temperature (operation)
-40 °C - 85 °C (Plug / socket)
Degree of protection
IP65

Line characteristics

Note
This item is a sensor/actuator cable with a freely selectable cable type. The technical data for all possible cable types is listed in the table below.

Environmental Product Compliance

China RoHS
Environmentally friendly use period: unlimited = EFUP-e
China RoHS
No hazardous substances above threshold values

Shielded black RADOX<sup>®</sup> [28R]

Cable type
Shielded black RADOX®
Cable type (abbreviation)
28R
Conductor cross section
4x 0.5 mm²
AWG signal line
20
Conductor structure signal line
19x 0.18 mm
Core diameter including insulation
1.43 mm
Wire colors
White 1, white 2, white 3, white 4
Overall twist
4 wires, twisted
Shielding
Tinned copper braided shield
External sheath, color
black
External cable diameter D
5.4 mm ±0.3 mm
Minimum bending radius, fixed installation
3 x D
Minimum bending radius, flexible installation
4 x D
Cable weight
56 kg/km
Outer sheath, material
PE-X
Material conductor insulation
PE-X
Conductor material
Tin-plated Cu litz wires
Conductor resistance
≤ 40.1 Ω/km
Nominal voltage, cable
600 V AC (Core-ground, U₀)
Nominal voltage, cable
1000 V AC (Core-ground, U)
Nominal voltage, cable
≤ 720 V AC (core-ground)
Nominal voltage, cable
≤ 1200 V AC (Core-ground, Um)
Nominal voltage, cable
≤ 900 V DC (Core-ground, V₀)
Nominal voltage, cable
≤ 1500 V DC (core-core)
Test voltage, cable
3500 V AC (50 Hz, 5 min.)
Test voltage, cable
8400 V DC (50 Hz, 5 min.)
Fire protection in rail vehicles
BS 6853 (Category Ia, Ib, II)
Fire protection in rail vehicles
GM/RT 2130 (Category Ia, Ib, II)
Fire protection in rail vehicles
EN 45545 (Risk level HL1 - HL3)
Fire protection in rail vehicles
DIN 5510 (Fire protection level 1, 2, 3, 4)
Fire protection in rail vehicles
NF F16-101 (Category A1, A2, B)
Fire protection in rail vehicles
NF F16-101 (Class C/F0)
Fire protection in rail vehicles
NFPA 130
Fire protection in rail vehicles
UNI CEI 11170 (Risk level LR1 - LR4)
Flame resistance
EN 60332-1-2
Flame resistance
EN 50266
Flame resistance
EN 50305, 9.1.2
Flame resistance
NF C32-070, 2.1
Flame resistance
NF C32-070, 2.2
Flame resistance
UL 1685, 12 (FT4)
Flame resistance
in accordance with ISO 6722-1 5.22 (UN ECE-R 118.01)
Halogen-free
According to EN 50267-2-1
Resistance to oil
according to IRM 902, 72 h at 100 °C
Other resistance
Resistance to fuels according to IRM 903, 168 h at 70 °C
Concentration of fumes
BS 6853 D.8.7
Concentration of fumes
EN 61034-2
Concentration of fumes
UL 1685, 12 (FT4)
Fume corrosiveness
EN 50267-2-2
Fume toxicity
BS 6853 B.1
Fume toxicity
EN 50305, 9.2
Ambient temperature (operation)
-50 °C - 120 °C (cable, fixed installation)
Ambient temperature (operation)
-25 °C - 90 °C (cable, flexible installation)

Standards and Regulations

Standards/specifications
M12 connector IEC 61076-2-101
Standards/specifications
Shock, vibration EN 50155
Flammability rating according to UL 94
V0