PROFINET RADOX<sup>®</sup> railway application CAT5 [937]

Cable type
PROFINET RADOX® railway application CAT5
Cable type (abbreviation)
937
Signal type/category
PROFINET CAT5 (IEC 11801), 100 Mbps
Signal type/category
EtherCAT® CAT5 (IEC 11801), 100 Mbps
Cable structure
1x4xAWG22/7; SF/TQ
Conductor cross section
4x 0.34 mm²
AWG signal line
22
Conductor structure signal line
7x 0.25 mm
Core diameter including insulation
approx. 1.5 mm
Wire colors
white-blue, orange-yellow
Overall twist
Star quad
Shielding
Plastic-coated aluminum foil, tinned copper braided shield
External sheath, color
black RAL 9005
Outer sheath thickness
approx. 1 mm
External cable diameter D
6.6 mm ±0.4 mm
Minimum bending radius, fixed installation
6 x D
Cable weight
70 kg/km
Outer sheath, material
PE-X
Material conductor insulation
Foamed PE
Conductor material
silver-plated Cu litz wires
Conductor resistance
≤ 54.4 Ω/km
Working capacitance
≤ 65 pF (core-core)
Working capacitance
≤ 100 pF (core-shield)
Wave impedance
100 Ω ±5 Ω (f = 100 MHz)
Near end crosstalk attenuation (NEXT)
73 dB (with 1 MHz)
Near end crosstalk attenuation (NEXT)
70 dB (at 4 МHz)
Near end crosstalk attenuation (NEXT)
65 dB (at 10 MHz)
Near end crosstalk attenuation (NEXT)
57 dB (at 31.5 МHz)
Near end crosstalk attenuation (NEXT)
52 dB (at 62.5 МHz)
Near end crosstalk attenuation (NEXT)
48 dB (at 100 MHz)
Remote crosstalk attenuation (FEXT)
78 dB (with 1 MHz)
Remote crosstalk attenuation (FEXT)
77 dB (at 4 МHz)
Remote crosstalk attenuation (FEXT)
70 dB (at 10 MHz)
Remote crosstalk attenuation (FEXT)
65 dB (at 31.5 МHz)
Remote crosstalk attenuation (FEXT)
56 dB (at 62.5 МHz)
Remote crosstalk attenuation (FEXT)
48 dB (at 100 MHz)
Attenuation
2 dB (with 1 MHz)
Attenuation
4.4 dB (at 4 МHz)
Attenuation
7.4 dB (at 10 MHz)
Attenuation
14 dB (at 31.5 МHz)
Attenuation
20 dB (at 62.5 МHz)
Attenuation
26 dB (at 100 MHz)
Return loss (RL)
25 dB (at 4 МHz)
Return loss (RL)
30 dB (at 10 MHz)
Return loss (RL)
30 dB (at 31.5 МHz)
Return loss (RL)
30 dB (at 62.5 МHz)
Return loss (RL)
28 dB (at 100 MHz)
Signal speed
75 c
Shield attenuation
40 dB (30 MHz ≤ f ≤ 100 MHz)
Coupling resistance
200.00 mΩ/m (f ≤ 30 MHz)
Nominal voltage, cable
300 V AC
Test voltage, cable
2000 V AC (50 Hz, 5 minutes)
Fire protection in rail vehicles
BS 6853 (Category Ia, Ib, II)
Fire protection in rail vehicles
GM/RT 2130 (Category Ia, Ib, II)
Fire protection in rail vehicles
EN 45545 (Risk level HL1 - HL3)
Fire protection in rail vehicles
DIN 5510 (Fire protection level 1, 2, 3, 4)
Fire protection in rail vehicles
NF F16-101 (Category A1, A2, B)
Fire protection in rail vehicles
NF F16-101 (Class C/F0)
Fire protection in rail vehicles
NFPA 130
Fire protection in rail vehicles
UNI CEI 11170 (Risk level LR1 - LR4)
Flame resistance
EN 60332-1-2
Flame resistance
EN 50266
Flame resistance
EN 60332-3-25
Flame resistance
NF C32-070, 2.1
Flame resistance
NF C32-070, 2.2
Flame resistance
UL 1685, 12 (FT4)
Flame resistance
in accordance with ISO 6722-1 5.22 (UN ECE-R 118.01)
Halogen-free
According to EN 50267-2-1
Resistance to oil
according to IRM 902, 72 h at 100 °C
Other resistance
Resistance to fuels according to IRM 903, 168 h at 70 °C
Concentration of fumes
BS 6853 D.8.7
Concentration of fumes
EN 61034-2
Concentration of fumes
UL 1685, 12 (FT4)
Fume corrosiveness
EN 50267-2-2
Fume toxicity
BS 6853 B.1
Fume toxicity
EN 50305, 9.2
Ambient temperature (operation)
-50 °C - 90 °C (cable, fixed installation)
Ambient temperature (operation)
-40 °C - 90 °C (cable, flexible installation)
Ambient temperature (installation)
-25 °C - 90 °C

Dimensions

Length of cable
Free input (0.2 - 40.0 m)

PROFINET BETAtrans<sup>®</sup> railway application CAT5 [939]

Cable type
PROFINET BETAtrans® railway application CAT5
Cable type (abbreviation)
939
Signal type/category
PROFINET CAT5 (IEC 11801), 100 Mbps
Cable structure
1x4xAWG22/7; SF/TQ
Conductor cross section
4x 0.34 mm²
AWG signal line
22
Conductor structure signal line
7x 0.25 mm
Core diameter including insulation
1.4 mm ±0.1 mm
Wire colors
white-blue, orange-yellow
Overall twist
Star quad
Shielding
Aluminum-lined polyester foil, tinned copper braided shield
External sheath, color
black
Outer sheath thickness
1 mm
External cable diameter D
6.6 mm ±0.2 mm
Minimum bending radius, fixed installation
5 x D
Minimum bending radius, flexible installation
6 x D
Tensile strength GRP
≤ 60 N (temporary)
Tensile strength GRP
≤ 15 N (Permanent)
Cable weight
71 kg/km
Outer sheath, material
PE-X
Material conductor insulation
Cell PE
Conductor material
Tin-plated Cu litz wires
Insulation resistance
≥ 5 GΩ*km
Conductor resistance
≤ 54.4 Ω/km
Cable capacity
44 nF/km (core-core)
Wave impedance
100 Ω ±5 Ω (f = 100 MHz)
Near end crosstalk attenuation (NEXT)
76 dB (with 1 MHz)
Near end crosstalk attenuation (NEXT)
71 dB (at 4 МHz)
Near end crosstalk attenuation (NEXT)
64 dB (at 10 MHz)
Near end crosstalk attenuation (NEXT)
60 dB (at 16 MHz)
Near end crosstalk attenuation (NEXT)
56 dB (at 31.25 МHz)
Near end crosstalk attenuation (NEXT)
52 dB (at 62.5 МHz)
Near end crosstalk attenuation (NEXT)
48 dB (at 100 MHz)
Near end crosstalk attenuation (NEXT)
45 dB (at 155 MHz)
Near end crosstalk attenuation (NEXT)
42 dB (at 200 MHz)
Power-summated near end crosstalk attenuation (PSNEXT)
73 dB (with 1 MHz)
Power-summated near end crosstalk attenuation (PSNEXT)
68 dB (at 4 МHz)
Power-summated near end crosstalk attenuation (PSNEXT)
61 dB (at 10 MHz)
Power-summated near end crosstalk attenuation (PSNEXT)
57 dB (at 16 MHz)
Power-summated near end crosstalk attenuation (PSNEXT)
53 dB (at 31.25 МHz)
Power-summated near end crosstalk attenuation (PSNEXT)
49 dB (at 62.5 МHz)
Power-summated near end crosstalk attenuation (PSNEXT)
45 dB (at 100 MHz)
Power-summated near end crosstalk attenuation (PSNEXT)
42 dB (at 155 MHz)
Power-summated near end crosstalk attenuation (PSNEXT)
39 dB (at 200 MHz)
Attenuation
1.5 dB (with 1 MHz)
Attenuation
3.3 dB (at 4 МHz)
Attenuation
5.3 dB (at 10 MHz)
Attenuation
6.9 dB (at 16 MHz)
Attenuation
9.9 dB (at 31.25 МHz)
Attenuation
14.5 dB (at 62.5 МHz)
Attenuation
18.8 dB (at 100 MHz)
Attenuation
23.6 dB (at 155 MHz)
Attenuation
27.3 dB (at 200 MHz)
Return loss (RL)
25 dB (with 1 MHz)
Return loss (RL)
25 dB (at 4 МHz)
Return loss (RL)
28 dB (at 10 MHz)
Return loss (RL)
28 dB (at 16 MHz)
Return loss (RL)
27 dB (at 31.25 МHz)
Return loss (RL)
26 dB (at 62.5 МHz)
Return loss (RL)
25 dB (at 100 MHz)
Return loss (RL)
25 dB (at 155 MHz)
Return loss (RL)
23 dB (at 200 MHz)
Signal speed
0.75 c
Signal runtime
4.4 ns/m
Shield attenuation
60 dB (up to 1000 MHz)
Coupling resistance
< 13.00 mΩ/m (f = 1 MHz)
Coupling resistance
< 8.00 mΩ/m (f = 10 MHz - 100 MHz)
Cable impedance
100 Ω ±15 Ω (f = 0.5 MHz - 3 MHz)
Nominal voltage, cable
125 V
Test voltage Core/Core
1000 V AC (50 Hz, 1 min.)
Test voltage Core/Shield
1000 V AC (50 Hz, 1 min.)
Fire protection in rail vehicles
BS 6853 (Internal cable Ia, Ib, II/external cable Ia, Ib, II)
Fire protection in rail vehicles
DIN 5510-2 (Fire protection level 1, 2, 3, 4)
Fire protection in rail vehicles
EN 45545-2 (Risk level HL1 - HL3)
Fire protection in rail vehicles
EN 50306-4
Fire protection in rail vehicles
NF F16-101 (Classification C/F1)
Fire protection in rail vehicles
NF F16-101 (Internal cable A1, A2, B/external cable A1, A2, B)
Fire protection in rail vehicles
NFPA 130
Fire protection in rail vehicles
PN-K-02511
Fire protection in rail vehicles
UIC 564-2 (Class A)
Flame resistance
according to EN 60332-1-2
Flame resistance
according to EN 50266-2-5
Flame resistance
according to ISO 14572 5.21 (UN ECE-R 118.01)
Halogen-free
According to EN 50267-2-1
Halogen-free
according to EN 60684-2
Resistance to oil
according to EN 60684-2, 72 h at 100 °C, IRM 902
Other resistance
Resistant to fuel according to EN 60684-2, 72 h at 100 °C, IRM 903
Other resistance
Resistant to ozone according to EN 50306-4, 72 h at 40 °C, procedure B, volume concentration 200 x 10-⁶
Concentration of fumes
EN 61034-2
Ambient temperature (operation)
-40 °C - 85 °C (cable, fixed installation)
Ambient temperature (operation)
-25 °C - 70 °C (cable, flexible installation)

General data

Note
Further products with variable cable type and variable cable length can be found in the accessories section
Note
EMC connector consisting of socket insert 1636091 HC-M-EMV-BU/3-9,5 and socket contacts 1674969 CK1,6-ED-0,37BU AU
Rated current at 40°C
4 A
Rated voltage
48 V AC
Rated voltage
60 V DC
Number of positions
4
Signal type/category
PROFINET CAT5 (IEC 11801), 100 Mbps
Signal type/category
Ethernet CAT5 (IEC 11801), 100 Mbps
Standards/regulations
M12 connector IEC 61076-2-101
Overvoltage category
II
Degree of pollution
3
Degree of protection
IP65

Ambient conditions

Degree of protection
IP65 (M12 connector)
Degree of protection
IP20 (EMC connector)
Ambient temperature (operation)
-40 °C - 85 °C (Plug / socket)

Line characteristics

Note
This item is a network cable with a freely selectable cable type. The technical data for all possible cable types is listed in the table below.

PROFINET RADOX<sup>®</sup> railway application CAT5 reinforced [936]

Cable type
PROFINET RADOX® railway application CAT5 reinforced
Cable type (abbreviation)
936
Signal type/category
PROFINET CAT5 (IEC 11801), 100 Mbps
Cable structure
1x4xAWG22/7; SF/TQ
Conductor cross section
4x 0.34 mm²
AWG signal line
22
Conductor structure signal line
7x 0.25 mm
Core diameter including insulation
1.95 mm
Wire colors
white-blue, orange-yellow
Overall twist
Star quad
Shielding
Plastic-coated aluminum foil, tinned copper braided shield
Optical shield covering
100 %
External sheath, color
black RAL 9005
Outer sheath thickness
≥ 0.8 mm
External cable diameter D
7.25 mm ±0.3 mm
Minimum bending radius, fixed installation
6 x D
Minimum bending radius, flexible installation
10 x D
Cable weight
81 g/m
Outer sheath, material
PE-X
Material conductor insulation
PE-X
Conductor material
silver-plated Cu litz wires
Conductor resistance
≤ 54.4 Ω/km
Working capacitance
≤ 65 pF (core-core)
Working capacitance
≤ 100 pF (core-shield)
Wave impedance
100 Ω ±5 Ω (f = 100 MHz)
Near end crosstalk attenuation (NEXT)
80 dB (with 1 MHz)
Near end crosstalk attenuation (NEXT)
76 dB (at 4 МHz)
Near end crosstalk attenuation (NEXT)
67 dB (at 10 MHz)
Near end crosstalk attenuation (NEXT)
60 dB (at 31.5 МHz)
Near end crosstalk attenuation (NEXT)
56 dB (at 62.5 МHz)
Near end crosstalk attenuation (NEXT)
53 dB (at 100 MHz)
Remote crosstalk attenuation (FEXT)
80 dB (with 1 MHz)
Remote crosstalk attenuation (FEXT)
70 dB (at 4 МHz)
Remote crosstalk attenuation (FEXT)
65 dB (at 10 MHz)
Remote crosstalk attenuation (FEXT)
58 dB (at 31.5 МHz)
Remote crosstalk attenuation (FEXT)
59 dB (at 62.5 МHz)
Remote crosstalk attenuation (FEXT)
67 dB (at 100 MHz)
Attenuation
2 dB (with 1 MHz)
Attenuation
4 dB (at 4 МHz)
Attenuation
6.5 dB (at 10 MHz)
Attenuation
10.5 dB (at 31.5 МHz)
Attenuation
14 dB (at 62.5 МHz)
Attenuation
18 dB (at 100 MHz)
Return loss (RL)
35 dB (at 4 МHz)
Return loss (RL)
35 dB (at 10 MHz)
Return loss (RL)
35 dB (at 31.5 МHz)
Return loss (RL)
33 dB (at 62.5 МHz)
Return loss (RL)
33 dB (at 100 MHz)
Signal speed
66 c
Shield attenuation
40 dB (30 MHz ≤ f ≤ 100 MHz)
Coupling resistance
200.00 mΩ/m (f ≤ 30 MHz)
Nominal voltage, cable
300 V AC
Test voltage, cable
2000 V AC (50 Hz, 5 minutes)
Fire protection in rail vehicles
BS 6853 (Category Ia, Ib, II)
Fire protection in rail vehicles
GM/RT 2130 (Category Ia, Ib, II)
Fire protection in rail vehicles
EN 45545 (Risk level HL1 - HL3)
Fire protection in rail vehicles
DIN 5510 (Fire protection level 1, 2, 3, 4)
Fire protection in rail vehicles
NF F16-101 (Category A1, A2, B)
Fire protection in rail vehicles
NF F16-101 (Class C/F0)
Fire protection in rail vehicles
NFPA 130
Fire protection in rail vehicles
UNI CEI 11170 (Risk level LR1 - LR4)
Flame resistance
EN 60332-1-2
Flame resistance
EN 50266
Flame resistance
EN 60332-3-25
Flame resistance
NF C32-070, 2.1
Flame resistance
NF C32-070, 2.2
Flame resistance
UL 1685, 12 (FT4)
Flame resistance
in accordance with ISO 6722-1 5.22 (UN ECE-R 118.01)
Halogen-free
According to EN 50267-2-1
Resistance to oil
according to IRM 902, 72 h at 100 °C
Other resistance
Resistance to fuels according to IRM 903, 168 h at 70 °C
Concentration of fumes
BS 6853 D.8.7
Concentration of fumes
EN 61034-2
Concentration of fumes
UL 1685, 12 (FT4)
Fume corrosiveness
EN 50267-2-2
Fume toxicity
BS 6853 B.1
Fume toxicity
EN 50305, 9.2
Ambient temperature (operation)
-50 °C - 90 °C (cable, fixed installation)
Ambient temperature (operation)
-40 °C - 90 °C (cable, flexible installation)

Environmental Product Compliance

China RoHS
Environmentally friendly use period: unlimited = EFUP-e
China RoHS
No hazardous substances above threshold values

Characteristics head 2

Head type
EMC socket insert straight / IP20
No. of positions (pin connector pattern)
4
Color
silver
Color
black
Material (component)
Copper alloy (Contact)
Material (component)
Au (Contact surface)
Material (component)
PC (Insulation)
Material (component)
Zinc alloy (Phase conductors)
Shielded
yes
Insertion/withdrawal cycles
≥ 500
Ambient temperature (operation)
-40 °C - 85 °C

Standards and Regulations

Standards/specifications
M12 connector IEC 61076-2-101
Flammability rating according to UL 94
V0

Characteristics head 1

Head type
Plug straight M12 SPEEDCON / IP65
No. of positions (pin connector pattern)
4
Coding
D (Data)
Color
black
Material (component)
CuSn (Contact)
Material (component)
Ni/Au (Contact surface)
Material (component)
PA 6.6 (Contact carriers)
Material (component)
PA 6.6 (Grip)
Material (component)
Zinc die-cast, nickel-plated (Screw connection)
Standards/regulations material
PA 6.6: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DIN EN 45545-2 (Risk level HL1 - HL3)
Shielded
yes
Insulation resistance
≥ 100 MΩ
Insertion/withdrawal cycles
≥ 100
Torque
0.4 Nm
Ambient temperature (operation)
-40 °C - 85 °C
Type type, plug side
Plug straight

Other Categories