Network cable - NBC-R4AC/1,0-94B/R4MC - 1414424
1414424
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:

Additional Information

Part Number
1414424
UPC
4055626043937
ETIM
Group Code : EG000037
Group Description : Data and telecommunication
Class Description : Patch cord copper (twisted pair)
Class Code : EC001262
Version : 7

Dimensions

Length of cable
1.00 m

General data

Number of positions
8
Degree of pollution
2
Alternative short product description
Ethernet cable
Rated voltage (III/3)
72 V (DC)
Degree of protection
IP67/IP20

Environmental Product Compliance

China RoHS
Environmentally friendly use period: unlimited = EFUP-e
China RoHS
No hazardous substances above threshold values

Standards and Regulations

Flammability rating according to UL 94
V2

Characteristics head 1

Shielded
yes
Outer sheath, material
PUR
External sheath, color
water blue RAL 5021

Cable

Cable type
Ethernet flexible CAT5, 4-pair
Cable type (abbreviation)
94B
UL AWM style
20963 (80°C/30 V)
Signal type/category
Ethernet CAT5 (IEC 11801), 1 Gbps
Cable structure
4x2xAWG26/7; SF/UTP
Conductor cross section
4x 2x 0.14 mm²
AWG signal line
26
Conductor structure signal line
7x 0.16 mm
Core diameter including insulation
0.96 mm
Wire colors
white/blue-blue, white/orange-orange, white/green-green, white/brown-brown
Twisted pairs
2 cores to the pair
Overall twist
4 pairs for core
Shielding
Aluminum-coated foil, tinned copper braided shield
Optical shield covering
70 %
External sheath, color
water blue RAL 5021
Outer sheath thickness
1.05 mm
External cable diameter D
6.4 mm ±0.2 mm
Minimum bending radius, fixed installation
4 x D
Minimum bending radius, flexible installation
8 x D
Tensile strength GRP
≤ 100 N
Cable weight
47 kg/km
Outer sheath, material
PUR
Material conductor insulation
Foamed PE
Conductor material
Bare Cu litz wires
Insulation resistance
≥ 500 MΩ*km
Loop resistance
≤ 290.00 Ω/km
Cable capacity
48 nF/km (at 1 kHz)
Wave impedance
100 Ω ±5 Ω (at 100 MHz)
Near end crosstalk attenuation (NEXT)
71.3 dB (with 1 MHz)
Near end crosstalk attenuation (NEXT)
62.3 dB (at 4 МHz)
Near end crosstalk attenuation (NEXT)
56.3 dB (at 10 MHz)
Near end crosstalk attenuation (NEXT)
53.2 dB (at 16 MHz)
Near end crosstalk attenuation (NEXT)
51.8 dB (at 20 МHz)
Near end crosstalk attenuation (NEXT)
48.9 dB (at 31.25 МHz)
Near end crosstalk attenuation (NEXT)
44.4 dB (at 62.5 МHz)
Near end crosstalk attenuation (NEXT)
41.3 dB (at 100 MHz)
Power-summated near end crosstalk attenuation (PSNEXT)
62.3 dB (with 1 MHz)
Power-summated near end crosstalk attenuation (PSNEXT)
53.3 dB (at 4 МHz)
Power-summated near end crosstalk attenuation (PSNEXT)
47.3 dB (at 10 MHz)
Power-summated near end crosstalk attenuation (PSNEXT)
44.2 dB (at 16 MHz)
Power-summated near end crosstalk attenuation (PSNEXT)
42.8 dB (at 20 МHz)
Power-summated near end crosstalk attenuation (PSNEXT)
39.9 dB (at 31.25 МHz)
Power-summated near end crosstalk attenuation (PSNEXT)
35.4 dB (at 62.5 МHz)
Power-summated near end crosstalk attenuation (PSNEXT)
32.3 dB (at 100 MHz)
Attenuation
3.2 dB (with 1 MHz)
Attenuation
6 dB (at 4 МHz)
Attenuation
9.5 dB (at 10 MHz)
Attenuation
12.1 dB (at 16 MHz)
Attenuation
13.6 dB (at 20 МHz)
Attenuation
17.1 dB (at 31.25 МHz)
Attenuation
24.8 dB (at 62.5 МHz)
Attenuation
32 dB (at 100 MHz)
Return loss (RL)
23 dB (at 4 МHz)
Return loss (RL)
24.1 dB (at 8 МHz)
Return loss (RL)
25 dB (at 10 MHz)
Return loss (RL)
25 dB (at 16 MHz)
Return loss (RL)
25 dB (at 20 МHz)
Return loss (RL)
23.6 dB (at 31.25 МHz)
Return loss (RL)
21.5 dB (at 62.5 МHz)
Return loss (RL)
20.1 dB (at 100 MHz)
Signal runtime
5.3 ns/m
Coupling resistance
≤ 100.00 mΩ/m (at 10 MHz)
Nominal voltage, cable
≤ 100 V
Test voltage Core/Core
700 V (50 Hz, 1 min.)
Test voltage Core/Shield
700 V (50 Hz, 1 min.)
Flame resistance
according to IEC 60332-1-2
Halogen-free
according to IEC 60754-1
Resistance to oil
according to EN 60811-2-1
Ambient temperature (operation)
-40 °C - 80 °C (cable, fixed installation)
Ambient temperature (operation)
-20 °C - 80 °C (cable, flexible installation)
Ambient temperature (installation)
-20 °C - 80 °C
Ambient temperature (storage/transport)
-20 °C - 80 °C