Power cable 1414874
1414874
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:

Additional Information

Part Number
1414874
UPC
4055626035048
Country of Origin
PL

Dimensions

Length of cable
3 m

Material

Flammability rating according to UL 94
V0
Contact material
CuSn
Contact surface material
Ni/Au
Contact carrier material
PA
Material of grip body
PA
Material, knurls
Zinc die-cast, nickel-plated

Ambient conditions

Ambient temperature (operation)
-25 °C - 85 °C (Plug / socket)
Degree of protection
IP65
Degree of protection
IP67

Environmental Product Compliance

REACh SVHC
Lead 7439-92-1
China RoHS
Environmentally Friendly Use Period = 50
China RoHS
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Standards and Regulations

Standard designation
M12 connector
Standards/regulations
IEC 61076-2-111
Flammability rating according to UL 94
V0

Cable

Cable type
PVC
Cable type (abbreviation)
PVC
UL AWM style
2570 / 10914 (80°C/1000 V)
Conductor cross section
5x 2.5 mm²
AWG power supply
14
Conductor structure, voltage supply
141x 0.15 mm
Core diameter including insulation
3 mm ±0.1 mm
Thickness, insulation
≥ 0.36 mm
Wire colors
Black 1, black 2, black 3, black 4, green/yellow
External sheath, color
orange RAL 2003
Outer sheath thickness
approx. 0.76 mm
External cable diameter D
11.45 mm ±0,3 mm
Minimum bending radius, fixed installation
5 x D
Minimum bending radius, flexible installation
10 x D
Number of bending cycles
1000000
Minimum bending radius, drag chain applications
10 x D
Traversing path
10 m
Traversing rate
3 m/s
Acceleration
10 m/s²
Cable weight
249 kg/km
Outer sheath, material
PVC
Material conductor insulation
PVC
Conductor material
Bare Cu litz wires
Insulation resistance
≥ 100 MΩ*km (at 20 °C)
Conductor resistance
≤ 8 Ω/km (at 20 °C)
Nominal voltage, cable
≤ 1000 V AC
Test voltage, cable
≥ 10000 V AC (Spark test)
Flame resistance
According to UL 758/1581 (Cable Flame)
Flame resistance
according to UL 758/1581 FT1
Flame resistance
According to DIN EN 60332-1-2
Resistance to oil
According to DIN EN 60811-404, 168 h at 60 °C
Ambient temperature (operation)
-40 °C - 80 °C (cable, fixed installation)
Ambient temperature (operation)
-20 °C - 80 °C (cable, flexible installation)