Bus system cable - SAC-5P-M12MRB/900/... - 1430970
1430970
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

Pin assignment

Contact | Color (signal designation) | Contact (optional)
1 (Plug) | YE (DO)
Contact | Color (signal designation) | Contact (optional)
2 (Plug) | GN (DO)
Contact | Color (signal designation) | Contact (optional)
3 (Plug) | GY (DI)
Contact | Color (signal designation) | Contact (optional)
4 (Plug) | PK (DI)
Contact | Color (signal designation) | Contact (optional)
5 (Plug) | BN (GND)

Dimensions

Length of cable
Free input (0.2 - 40.0 m)
Stripping length of the free conductor end
50 mm

Material

Flammability rating according to UL 94
V0
Contact material
CuSn
Contact surface material
Ni/Au
Contact carrier material
PA 6.6
Material of grip body
TPU, hardly inflammable, self-extinguishing
Material, knurls
Zinc die-cast, nickel-plated

Ambient conditions

Ambient temperature (operation)
-25 °C - 90 °C (Plug / socket)
Degree of protection
IP65
Degree of protection
IP67

Environmental Product Compliance

REACh SVHC
Lead 7439-92-1
China RoHS
Environmentally Friendly Use Period = 50 years
China RoHS
For details about hazardous substances go to tab 'Downloads', Category 'Manufacturer's declaration'

Standards and Regulations

Flammability rating according to UL 94
V0

Cable

Cable type
INTERBUS
Cable type (abbreviation)
900
Cable structure
3 x 2 x 0.22 mm²
Conductor cross section
3x 2x 0.22 mm²
AWG signal line
24
Conductor structure signal line
32x 0.10 mm
Wire colors
Green-yellow, white-brown, gray-pink
Twisted pairs
2 cores to the pair
Overall twist
3 pairs to the core
Shielding
Braided copper wires
External sheath, color
may green RAL 6017
External cable diameter D
8 mm
Minimum bending radius, fixed installation
7.5 x D
Minimum bending radius, flexible installation
15 x D
Number of bending cycles
5000000
Bending radius
120 mm
Traversing path
10 m
Traversing rate
1.6 m/s
Acceleration
3.2 m/s²
Cable weight
70 kg/km
Outer sheath, material
PUR
Material conductor insulation
PE
Conductor material
Bare Cu litz wires
Insulation resistance
≥ 5 GΩ*km
Loop resistance
≤ 159.80 Ω/km
Cable capacity
≤ 60 nF/km (At 800 Hz)
Wave impedance
120 Ω ±20 % (at 64 kHz)
Wave impedance
100 Ω ±15 % (with 1 MHz)
Near end crosstalk attenuation (NEXT)
≥ 61 dB (at 772 kHz)
Near end crosstalk attenuation (NEXT)
≥ 59 dB (with 1 MHz)
Near end crosstalk attenuation (NEXT)
≥ 55 dB (at 2 МHz)
Near end crosstalk attenuation (NEXT)
≥ 50 dB (at 4 МHz)
Near end crosstalk attenuation (NEXT)
≥ 46 dB (at 8 МHz)
Near end crosstalk attenuation (NEXT)
≥ 44 dB (at 10 MHz)
Near end crosstalk attenuation (NEXT)
≥ 41 dB (at 16 MHz)
Near end crosstalk attenuation (NEXT)
≥ 40 dB (at 20 МHz)
Attenuation
≤ 15 dB/km (at 256 kHz)
Attenuation
≤ 24 dB/km (at 772 kHz)
Attenuation
≤ 27 dB/km (with 1 MHz)
Attenuation
≤ 52 dB/km (at 4 МHz)
Attenuation
≤ 84 dB/km (at 10 MHz)
Attenuation
≤ 112 dB/km (at 16 MHz)
Attenuation
≤ 119 dB/km (at 20 МHz)
Signal speed
0.66 c
Coupling resistance
< 250.00 mΩ/m (at 30 MHz)
Nominal voltage, cable
250 V (Peak value, not for high-power applications)
Test voltage Core/Core
1500 Vrms
Test voltage Core/Shield
1000 Vrms
Flame resistance
according to VDE 0472, Part 4, test type B
Flame resistance
according to IEC 60332-1
Ambient temperature (operation)
-40 °C - 80 °C (cable, fixed installation)
Ambient temperature (operation)
-30 °C - 70 °C (cable, flexible installation)