Bus system cable - SAC-4P-M12MS FF VA/.../... - 1431322
1431322
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

Fieldbus FOUNDATION/PROFIBUS PA, blue [961]

Cable type
Fieldbus FOUNDATION/PROFIBUS PA, blue
Cable type (abbreviation)
961
Cable structure
2xAWG18/7 + 1xAWG20/7
Conductor cross section
2x 0.75 mm² (Signal line)
Conductor cross section
1x 0.5 mm² (Drain wire)
AWG signal line
18
Conductor structure signal line
7x 0.40 mm
Core diameter including insulation
2.24 mm ±0.05 mm
Thickness, insulation
0.5 mm
Wire colors
Blue, orange
Twisted pairs
2 cores to the pair
Overall twist
One pair with one drain wire and fillers for core
Shielding
Plastic-coated aluminum foil with a drain wire
Optical shield covering
100 %
External sheath, color
blue RAL 5015
Outer sheath thickness
1 mm
External cable diameter D
7.5 mm ±0.25 mm
Smallest bending radius, fixed installation
75 mm
Cable weight
56.552 kg/km
Tensile strength GRP
260 N
Outer sheath, material
PVC
Material conductor insulation
PO (Signal line)
Conductor material
Tin-plated Cu litz wires
Conductor resistance
≤ 19.35 Ω/km (Signal line)
Conductor resistance
26 Ω/km (shield)
Working capacitance
78 nF (at 1 kHz)
Cable capacity
147 pF/m (at 1 kHz, core/shield)
Cable capacity
≤ 3.94 pF/m (capacitance unbalance)
Signal speed
0.66 c
Shield attenuation
3 dB/km (at 39 kHz)
Cable impedance
100 Ω ±20 % (At 31.25 kHz)
Conductor inductance
0.6233 µH/m
Nominal voltage, cable
300 V
Special properties
UL standards PLTC-ER and ITC
Flame resistance
UL 1685 (CSA FT 4)
Flame resistance
UL 1685 (vertical tray)
Flame resistance
UL 1666 (riser)
Ambient temperature (operation)
-40 °C - 105 °C (cable, fixed installation)

Dimensions

Length of cable
Free input (0.2 - 40.0 m)
Stripping length of the free conductor end
50 mm

Material

Flammability rating according to UL 94
HB
Contact material
CuSn
Contact surface material
Ni/Au
Contact carrier material
TPU GF
Material of grip body
TPU, hardly inflammable, self-extinguishing
Material, knurls
Stainless steel
Sealing material
NBR

Ambient conditions

Ambient temperature (operation)
-25 °C - 90 °C (Plug / socket)
Degree of protection
IP65
Degree of protection
IP67
Degree of protection
IP68
Degree of protection
IP69K

Line characteristics

Note
This item is a sensor/actuator cable with a freely selectable cable type. The technical data for all possible cable types is listed in the table below.

Environmental Product Compliance

REACh SVHC
Lead 7439-92-1
China RoHS
Environmentally Friendly Use Period = 50 years
China RoHS
For details about hazardous substances go to tab 'Downloads', Category 'Manufacturer's declaration'

FOUNDATION Fieldbus orange [960]

Cable type
FOUNDATION Fieldbus orange
Cable type (abbreviation)
960
Cable structure
2xAWG18/7 + 1xAWG20/7
Conductor cross section
2x 0.75 mm² (Signal line)
Conductor cross section
1x 0.5 mm² (Drain wire)
AWG signal line
18
Conductor structure signal line
7x 0.40 mm
Core diameter including insulation
2.24 mm ±0.05 mm
Thickness, insulation
0.5 mm
Wire colors
Blue, orange
Twisted pairs
2 cores to the pair
Overall twist
One pair with one drain wire and fillers for core
Shielding
Plastic-coated aluminum foil with a drain wire
Optical shield covering
100 %
External sheath, color
orange RAL 2003
Outer sheath thickness
1 mm
External cable diameter D
7.5 mm ±0.25 mm
Smallest bending radius, fixed installation
75 mm
Cable weight
56.552 kg/km
Tensile strength GRP
260 N
Outer sheath, material
PVC
Material conductor insulation
PO (Signal line)
Conductor material
Tin-plated Cu litz wires
Conductor resistance
≤ 19.35 Ω/km (Signal line)
Conductor resistance
26 Ω/km (shield)
Working capacitance
78 nF (at 1 kHz)
Cable capacity
147 pF/m (at 1 kHz, core/shield)
Cable capacity
≤ 3.94 pF/m (capacitance unbalance)
Signal speed
0.66 c
Shield attenuation
3 dB/km (at 39 kHz)
Cable impedance
100 Ω ±20 % (At 31.25 kHz)
Conductor inductance
0.6233 µH/m
Nominal voltage, cable
300 V
Special properties
UL standards PLTC-ER and ITC
Flame resistance
UL 1685 (CSA FT 4)
Flame resistance
UL 1685 (vertical tray)
Flame resistance
UL 1666 (riser)
Ambient temperature (operation)
-40 °C - 105 °C (cable, fixed installation)

Standards and Regulations

Flammability rating according to UL 94
HB

Other Categories