Phoenix Contact
1431393
Bus system cable - SAC-4P-M12MR-M12FR FF VA/... - 1431393
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Send request for price
1
Payment methods:
Fieldbus FOUNDATION/PROFIBUS PA, blue [961]
- Cable type
- Fieldbus FOUNDATION/PROFIBUS PA, blue
- Cable type (abbreviation)
- 961
- Cable structure
- 2xAWG18/7 + 1xAWG20/7
- Conductor cross section
- 2x 0.75 mm² (Signal line)
- Conductor cross section
- 1x 0.5 mm² (Drain wire)
- AWG signal line
- 18
- Conductor structure signal line
- 7x 0.40 mm
- Core diameter including insulation
- 2.24 mm ±0.05 mm
- Thickness, insulation
- 0.5 mm
- Wire colors
- Blue, orange
- Twisted pairs
- 2 cores to the pair
- Overall twist
- One pair with one drain wire and fillers for core
- Shielding
- Plastic-coated aluminum foil with a drain wire
- Optical shield covering
- 100 %
- External sheath, color
- blue RAL 5015
- Outer sheath thickness
- 1 mm
- External cable diameter D
- 7.5 mm ±0.25 mm
- Smallest bending radius, fixed installation
- 75 mm
- Cable weight
- 56.552 kg/km
- Tensile strength GRP
- 260 N
- Outer sheath, material
- PVC
- Material conductor insulation
- PO (Signal line)
- Conductor material
- Tin-plated Cu litz wires
- Conductor resistance
- ≤ 19.35 Ω/km (Signal line)
- Conductor resistance
- 26 Ω/km (shield)
- Working capacitance
- 78 nF (at 1 kHz)
- Cable capacity
- 147 pF/m (at 1 kHz, core/shield)
- Cable capacity
- ≤ 3.94 pF/m (capacitance unbalance)
- Signal speed
- 0.66 c
- Shield attenuation
- 3 dB/km (at 39 kHz)
- Cable impedance
- 100 Ω ±20 % (At 31.25 kHz)
- Conductor inductance
- 0.6233 µH/m
- Nominal voltage, cable
- 300 V
- Special properties
- UL standards PLTC-ER and ITC
- Flame resistance
- UL 1685 (CSA FT 4)
- Flame resistance
- UL 1685 (vertical tray)
- Flame resistance
- UL 1666 (riser)
- Ambient temperature (operation)
- -40 °C - 105 °C (cable, fixed installation)
Dimensions
- Length of cable
- Free input (0.2 - 40.0 m)
Material
- Flammability rating according to UL 94
- HB
- Contact material
- CuSn
- Contact surface material
- Ni/Au
- Contact carrier material
- TPU GF
- Material of grip body
- TPU, hardly inflammable, self-extinguishing
- Material, knurls
- Stainless steel
- Sealing material
- NBR
Ambient conditions
- Ambient temperature (operation)
- -25 °C - 90 °C (Plug / socket)
- Degree of protection
- IP65
- Degree of protection
- IP67
- Degree of protection
- IP68
- Degree of protection
- IP69K
Line characteristics
- Note
- This item is a sensor/actuator cable with a freely selectable cable type. The technical data for all possible cable types is listed in the table below.
Environmental Product Compliance
- REACh SVHC
- Lead 7439-92-1
- China RoHS
- Environmentally Friendly Use Period = 50 years
- China RoHS
- For details about hazardous substances go to tab 'Downloads', Category 'Manufacturer's declaration'
FOUNDATION Fieldbus orange [960]
- Cable type
- FOUNDATION Fieldbus orange
- Cable type (abbreviation)
- 960
- Cable structure
- 2xAWG18/7 + 1xAWG20/7
- Conductor cross section
- 2x 0.75 mm² (Signal line)
- Conductor cross section
- 1x 0.5 mm² (Drain wire)
- AWG signal line
- 18
- Conductor structure signal line
- 7x 0.40 mm
- Core diameter including insulation
- 2.24 mm ±0.05 mm
- Thickness, insulation
- 0.5 mm
- Wire colors
- Blue, orange
- Twisted pairs
- 2 cores to the pair
- Overall twist
- One pair with one drain wire and fillers for core
- Shielding
- Plastic-coated aluminum foil with a drain wire
- Optical shield covering
- 100 %
- External sheath, color
- orange RAL 2003
- Outer sheath thickness
- 1 mm
- External cable diameter D
- 7.5 mm ±0.25 mm
- Smallest bending radius, fixed installation
- 75 mm
- Cable weight
- 56.552 kg/km
- Tensile strength GRP
- 260 N
- Outer sheath, material
- PVC
- Material conductor insulation
- PO (Signal line)
- Conductor material
- Tin-plated Cu litz wires
- Conductor resistance
- ≤ 19.35 Ω/km (Signal line)
- Conductor resistance
- 26 Ω/km (shield)
- Working capacitance
- 78 nF (at 1 kHz)
- Cable capacity
- 147 pF/m (at 1 kHz, core/shield)
- Cable capacity
- ≤ 3.94 pF/m (capacitance unbalance)
- Signal speed
- 0.66 c
- Shield attenuation
- 3 dB/km (at 39 kHz)
- Cable impedance
- 100 Ω ±20 % (At 31.25 kHz)
- Conductor inductance
- 0.6233 µH/m
- Nominal voltage, cable
- 300 V
- Special properties
- UL standards PLTC-ER and ITC
- Flame resistance
- UL 1685 (CSA FT 4)
- Flame resistance
- UL 1685 (vertical tray)
- Flame resistance
- UL 1666 (riser)
- Ambient temperature (operation)
- -40 °C - 105 °C (cable, fixed installation)
Standards and Regulations
- Flammability rating according to UL 94
- HB