Pin assignment

Contact | Color (signal designation) | Contact (optional)
1 (Plug) | YE (DO) | 1 (Socket)
Contact | Color (signal designation) | Contact (optional)
2 (Plug) | GN (DO) | 2 (Socket)
Contact | Color (signal designation) | Contact (optional)
3 (Plug) | GY (DI) | 3 (Socket)
Contact | Color (signal designation) | Contact (optional)
4 (Plug) | PK (DI) | 4 (Socket)
Contact | Color (signal designation) | Contact (optional)
5 (Plug) | BN (GND) | 5 (Socket)

Dimensions

Length of cable
Free input (0.2 - 40.0 m)

Material

Flammability rating according to UL 94
V0
Contact material
CuSn
Contact surface material
Ni/Au
Contact carrier material
PA 6.6
Material of grip body
TPU, hardly inflammable, self-extinguishing
Material, knurls
Zinc die-cast, nickel-plated
Sealing material
NBR

Ambient conditions

Degree of protection
IP65
Degree of protection
IP67

Environmental Product Compliance

China RoHS
Environmentally friendly use period: unlimited = EFUP-e
China RoHS
No hazardous substances above threshold values

Standards and Regulations

Flammability rating according to UL 94
V0

Cable

Cable type
INTERBUS
Cable type (abbreviation)
900
Cable structure
3 x 2 x 0.22 mm²
Conductor cross section
3x 2x 0.22 mm²
AWG signal line
24
Conductor structure signal line
32x 0.10 mm
Wire colors
Green-yellow, white-brown, gray-pink
Twisted pairs
2 cores to the pair
Overall twist
3 pairs to the core
Shielding
Braided copper wires
External sheath, color
may green RAL 6017
External cable diameter D
8 mm
Minimum bending radius, fixed installation
7.5 x D
Minimum bending radius, flexible installation
15 x D
Number of bending cycles
5000000
Bending radius
120 mm
Traversing path
10 m
Traversing rate
1.6 m/s
Acceleration
3.2 m/s²
Cable weight
70 kg/km
Outer sheath, material
PUR
Material conductor insulation
PE
Conductor material
Bare Cu litz wires
Insulation resistance
≥ 5 GΩ*km
Loop resistance
≤ 159.80 Ω/km
Cable capacity
≤ 60 nF/km (At 800 Hz)
Wave impedance
120 Ω ±20 % (at 64 kHz)
Wave impedance
100 Ω ±15 % (with 1 MHz)
Near end crosstalk attenuation (NEXT)
≥ 61 dB (at 772 kHz)
Near end crosstalk attenuation (NEXT)
≥ 59 dB (with 1 MHz)
Near end crosstalk attenuation (NEXT)
≥ 55 dB (at 2 МHz)
Near end crosstalk attenuation (NEXT)
≥ 50 dB (at 4 МHz)
Near end crosstalk attenuation (NEXT)
≥ 46 dB (at 8 МHz)
Near end crosstalk attenuation (NEXT)
≥ 44 dB (at 10 MHz)
Near end crosstalk attenuation (NEXT)
≥ 41 dB (at 16 MHz)
Near end crosstalk attenuation (NEXT)
≥ 40 dB (at 20 МHz)
Attenuation
≤ 15 dB/km (at 256 kHz)
Attenuation
≤ 24 dB/km (at 772 kHz)
Attenuation
≤ 27 dB/km (with 1 MHz)
Attenuation
≤ 52 dB/km (at 4 МHz)
Attenuation
≤ 84 dB/km (at 10 MHz)
Attenuation
≤ 112 dB/km (at 16 MHz)
Attenuation
≤ 119 dB/km (at 20 МHz)
Signal speed
0.66 c
Coupling resistance
< 250.00 mΩ/m (at 30 MHz)
Nominal voltage, cable
250 V (Peak value, not for high-power applications)
Test voltage Core/Core
1500 Vrms
Test voltage Core/Shield
1000 Vrms
Flame resistance
according to VDE 0472, Part 4, test type B
Flame resistance
according to IEC 60332-1
Ambient temperature (operation)
-40 °C - 80 °C (cable, fixed installation)
Ambient temperature (operation)
-30 °C - 70 °C (cable, flexible installation)