PUR halogen-free gray [280]

Cable type
PUR halogen-free gray
Cable type (abbreviation)
280
Cable abbreviation
Li9Y11Y-HF
UL AWM style
20549
Conductor cross section
5x 0.5 mm² (Signal line)
AWG signal line
20
Conductor structure signal line
28x 0.15 mm
Core diameter including insulation
1.5 mm ±0.05 mm (Signal line)
Wire colors
Black 1, black 2, black 3, black 4, green/yellow
Overall twist
Wires twisted in layers
External sheath, color
gray RAL 7001
External cable diameter D
5.3 mm ±0.2 mm
Smallest bending radius, fixed installation
26.5 mm
Number of bending cycles
15000000
Bending radius
50 mm
Traversing path
0.9 m
Traversing rate
5 m/s
Acceleration
30 m/s²
Outer sheath, material
PUR
Material conductor insulation
PP
Conductor material
Bare Cu litz wires
Insulation resistance
≥ 20 MΩ*km
Conductor resistance
39 Ω/km (at 20 °C)
Nominal voltage, cable
300 V
Test voltage, cable
1200 V
Flame resistance
according to DIN VDE 0482
Flame resistance
According to DIN EN 50265-2-1
Resistance to oil
largely oil-resistant
Ambient temperature (operation)
-40 °C - 80 °C (cable, fixed installation)
Ambient temperature (operation)
-20 °C - 80 °C (cable, flexible installation)

PVC black [PVC]

Cable type
PVC black
Cable type (abbreviation)
PVC
Cable abbreviation
LiYY
UL AWM style
2464
Conductor cross section
5x 0.5 mm²
AWG signal line
20
Conductor structure signal line
16x 0.20 mm
Core diameter including insulation
1.5 mm ±0.05 mm
Wire colors
Black 1, black 2, black 3, black 4, green/yellow
Overall twist
5 cores, twisted
External sheath, color
black
External cable diameter D
5.6 mm ±0.2 mm
Minimum bending radius, fixed installation
5 x D
Outer sheath, material
PVC
Material conductor insulation
PVC
Conductor material
Bare Cu litz wires
Insulation resistance
≥ 20 MΩ*km
Conductor resistance
39 Ω/km (at 20 °C)
Nominal voltage, cable
300 V
Test voltage, cable
1200 V
Flame resistance
DIN VDE 0482
Flame resistance
DIN EN 50265-2-1
Resistance to oil
largely oil-resistant
Ambient temperature (operation)
-40 °C - 80 °C (cable, fixed installation)
Ambient temperature (operation)
-5 °C - 80 °C (cable, flexible installation)

PUR halogen-free yellow [240]

Cable type
PUR halogen-free yellow
Cable type (abbreviation)
240
Cable abbreviation
Li9Y11Y-HF
UL AWM style
20549
Conductor cross section
5x 0.5 mm² (Signal line)
AWG signal line
20
Conductor structure signal line
28x 0.15 mm
Core diameter including insulation
1.5 mm ±0.05 mm (Signal line)
Wire colors
Black 1, black 2, black 3, black 4, green/yellow
Overall twist
Wires twisted in layers
External sheath, color
yellow
External cable diameter D
5.3 mm ±0.2 mm
Smallest bending radius, fixed installation
26.5 mm
Number of bending cycles
15000000
Bending radius
50 mm
Traversing path
0.9 m
Traversing rate
5 m/s
Acceleration
30 m/s²
Outer sheath, material
PUR
Material conductor insulation
PP
Conductor material
Bare Cu litz wires
Insulation resistance
≥ 20 MΩ*km
Conductor resistance
39 Ω/km (at 20 °C)
Nominal voltage, cable
300 V
Test voltage, cable
1200 V
Flame resistance
according to DIN VDE 0482
Flame resistance
According to DIN EN 50265-2-1
Resistance to oil
largely oil-resistant
Ambient temperature (operation)
-40 °C - 80 °C (cable, fixed installation)
Ambient temperature (operation)
-20 °C - 80 °C (cable, flexible installation)

Dimensions

Length of cable
Free input (0.2 - 40.0 m)
Central screw valve connector
M3 x 29

PVC, 0.75 mm², black [534]

UL AWM style
2464 (80°C/300 V)
Conductor cross section
5x 0.75 mm² (Signal line)
AWG signal line
18
Conductor structure signal line
24x 0.20 mm
Core diameter including insulation
1.7 mm ±0.1 mm
Wire colors
Black 1, black 2, black 3, black 4, green/yellow
Overall twist
5 cores, twisted
External sheath, color
black
External cable diameter D
6.2 mm ±0.2 mm
Minimum bending radius, fixed installation
5 x D
Outer sheath, material
PVC
Material conductor insulation
PVC
Conductor material
Bare Cu litz wires
Insulation resistance
min. 20 MΩ*km (at 20 °C)
Conductor resistance
26 Ω/km (at 20 °C)
Nominal voltage, cable
300 V
Test voltage, cable
1200 V
Flame resistance
DIN VDE 0482
Flame resistance
DIN EN 50265-2-1
Flame resistance
in acc. to UL VW1
Resistance to oil
in accordance with DIN EN 60811-2-1
Ambient temperature (operation)
-40 °C - 80 °C (cable, fixed installation)
Ambient temperature (operation)
-5 °C - 80 °C (cable, flexible installation)

Material

Flammability rating according to UL 94
V0
Valve plug contact material
CuSn
Valve plug contact surface material
Sn
Valve plug contact insert material
PA 6
Material housing valve plug
TPU
Sealing material
TPU (Seal molded)

PUR/PVC, 0.75 mm², black [116]

Cable abbreviation
LiYY11Y
UL AWM style
20549
Conductor cross section
5x 0.75 mm² (Signal line)
AWG signal line
18
Conductor structure signal line
24x 0.20 mm
Core diameter including insulation
1.7 mm ±0.05 mm
Wire colors
Black 1, black 2, black 3, black 4, green/yellow
Overall twist
5 cores, twisted
External sheath, color
black RAL 9005
External cable diameter D
6.9 mm ±0.2 mm
Smallest bending radius, fixed installation
35 mm
Smallest bending radius, movable installation
69 mm
Number of bending cycles
1000000
Bending radius
69 mm
Traversing rate
2 m/s
Acceleration
2.5 m/s²
Outer sheath, material
PUR
Material, inner sheath
PVC
Material conductor insulation
PVC
Conductor material
Bare Cu litz wires
Insulation resistance
≥ 20 MΩ*km
Conductor resistance
26 Ω/km (at 20 °C)
Nominal voltage, cable
300 V
Test voltage, cable
1200 V
Special properties
Free of substances which would hinder coating with paint or varnish
Flame resistance
DIN VDE 0482
Flame resistance
DIN EN 50265-2-1
Flame resistance
in acc. with UL FT-2
Ambient temperature (operation)
-40 °C - 80 °C (cable, fixed installation)
Ambient temperature (operation)
-5 °C - 80 °C (cable, flexible installation)

PUR halogen-free black [PUR]

Cable type
PUR halogen-free black
Cable type (abbreviation)
PUR
Cable abbreviation
Li9Y11Y-HF
UL AWM style
20549
Conductor cross section
5x 0.5 mm²
AWG signal line
20
Conductor structure signal line
28x 0.15 mm
Core diameter including insulation
1.5 mm ±0.05 mm (Signal line)
Wire colors
Black 1, black 2, black 3, black 4, green/yellow
Overall twist
5 cores, twisted
External sheath, color
black-gray RAL 7021
External cable diameter D
5.3 mm ±0.02 mm
Smallest bending radius, fixed installation
26.5 mm
Smallest bending radius, movable installation
53 mm
Number of bending cycles
15000000
Bending radius
50 mm
Traversing path
0.9 m
Traversing rate
5 m/s
Acceleration
30 m/s²
Outer sheath, material
PUR
Material conductor insulation
PP
Conductor material
Bare Cu litz wires
Insulation resistance
min. 20 MΩ*km
Conductor resistance
39 Ω/km (at 20 °C)
Nominal voltage, cable
≤ 300 V
Test voltage, cable
≥ 1200 V
Special properties
Flexible cable conduit capable
Special properties
Silicone-free
Special properties
Free of substances which would hinder coating with paint or varnish
Flame resistance
in accordance with DIN UL-Style 20549
Halogen-free
in accordance with DIN VDE 0472 part 815
Resistance to oil
in accordance with DIN EN 60811-2-1
Other resistance
Highly resistant to acids, alkaline solutions and solvents
Other resistance
hydrolysis and microbe resistant
Other resistance
largely oil-resistant
Other resistance
partly UV-resistant in accordance with DIN EN ISO 4892-2-A
Ambient temperature (operation)
-40 °C - 80 °C (cable, fixed installation)
Ambient temperature (operation)
-20 °C - 80 °C (cable, flexible installation)

PUR, halogen-free, highly stranded, resistant to welding sparks, gray [800]

Note
Due to the extremely robust outer sheath, this cable should only be stripped in 5 cm increments.
Cable abbreviation
LiF9Y11Y
UL AWM style
20549
Conductor cross section
5x 0.5 mm² (Signal line)
AWG signal line
20
Conductor structure signal line
28x 0.15 mm
Core diameter including insulation
1.5 mm ±0.05 mm (Signal line)
Wire colors
Black 1, black 2, black 3, black 4, green/yellow
Overall twist
Wires twisted in layers
External sheath, color
gray RAL 7001
External cable diameter D
5.3 mm ±0.2 mm
Minimum bending radius, fixed installation
5 x D
Minimum bending radius, flexible installation
5 x D
Number of bending cycles
15000000
Bending radius
50 mm
Traversing path
0.9 m
Traversing rate
5 m/s
Acceleration
30 m/s²
Torsion force
± 360 °/m
Cable weight
44 kg/km
Outer sheath, material
PUR
Material conductor insulation
PP
Conductor material
Bare Cu litz wires
Insulation resistance
≥ 20 MΩ*km
Conductor resistance
39 Ω/km (at 20 °C)
Nominal voltage, cable
300 V
Test voltage, cable
1200 V
Special properties
Cable jacket is welding spark-resistant, recyclable, matt, low-adhesion, abrasion-resistant, flame-retardant, and self-extinguishing
Special properties
Free from silicone and cadmium
Special properties
Free of substances which would hinder coating with paint or varnish
Flame resistance
in accordance with UL 758/1581 FT2
Halogen-free
The cable is halogen-free
Resistance to oil
in accordance with DIN EN 60811-2-1
Other resistance
Highly resistant to acids, alkaline solutions and solvents
Ambient temperature (operation)
-40 °C - 80 °C (cable, fixed installation)
Ambient temperature (operation)
-25 °C - 80 °C (cable, flexible installation)

PVC gray [500]

Cable abbreviation
LiYY
Conductor cross section
5x 0.5 mm² (Signal line)
AWG signal line
20
Conductor structure signal line
28x 0.15 mm
Core diameter including insulation
1.5 mm ±0.05 mm (Signal line)
Wire colors
Black 1, black 2, black 3, black 4, green/yellow
Overall twist
Wires twisted in layers
External sheath, color
gray
External cable diameter D
5.6 mm ±0.2 mm
Smallest bending radius, fixed installation
28 mm
Outer sheath, material
PVC
Material conductor insulation
PVC
Conductor material
Bare Cu litz wires
Insulation resistance
≥ 20 MΩ*km
Conductor resistance
39 Ω/km (at 20 °C)
Nominal voltage, cable
300 V
Test voltage, cable
1200 V
Flame resistance
according to DIN VDE 0482
Flame resistance
According to DIN EN 50265-2-1
Resistance to oil
largely oil-resistant
Ambient temperature (operation)
-40 °C - 80 °C (cable, fixed installation)
Ambient temperature (operation)
-5 °C - 80 °C (cable, flexible installation)

Ambient conditions

Ambient temperature (operation)
-20 °C - 85 °C (valve plug)
Degree of protection
IP65
Degree of protection
IP67

Line characteristics

Note
This item is a sensor/actuator cable with a freely selectable cable type. The technical data for all possible cable types is listed in the table below.

Environmental Product Compliance

China RoHS
Environmentally friendly use period: unlimited = EFUP-e
China RoHS
No hazardous substances above threshold values

Standards and Regulations

Standards/specifications
Valve connector EN 175301-803
Flammability rating according to UL 94
V0