Request a Quote and we will send you information on availability and price.

PUR halogen-free gray [280]

Cable type
PUR halogen-free gray
Cable type (abbreviation)
280
Cable abbreviation
Li9Y11Y-HF
UL AWM style
20549
Conductor cross section
3x 0.5 mm² (Signal line)
AWG signal line
20
Conductor structure signal line
28x 0.15 mm
Core diameter including insulation
1.5 mm ±0.05 mm (Signal line)
Wire colors
black 1, black 2, green/yellow
Overall twist
Wires twisted in layers
External sheath, color
gray RAL 7001
External cable diameter D
4.5 mm ±0.2 mm
Smallest bending radius, fixed installation
22.5 mm
Number of bending cycles
15000000
Bending radius
50 mm
Traversing path
0.9 m
Traversing rate
5 m/s
Acceleration
30 m/s²
Outer sheath, material
PUR
Material conductor insulation
PP
Conductor material
Bare Cu litz wires
Insulation resistance
≥ 20 MΩ*km
Conductor resistance
39 Ω/km (at 20 °C)
Nominal voltage, cable
300 V
Test voltage, cable
1200 V
Flame resistance
according to DIN VDE 0482
Flame resistance
According to DIN EN 50265-2-1
Resistance to oil
largely oil-resistant
Ambient temperature (operation)
-40 °C - 80 °C (cable, fixed installation)
Ambient temperature (operation)
-20 °C - 80 °C (cable, flexible installation)

PVC black [PVC]

Cable type
PVC black
Cable type (abbreviation)
PVC
Cable abbreviation
LiYY
UL AWM style
2464
Conductor cross section
3x 0.5 mm²
AWG signal line
20
Conductor structure signal line
16x 0.20 mm
Core diameter including insulation
1.5 mm ±0.05 mm
Wire colors
black 1, black 2, green/yellow
Overall twist
3 wires, twisted
External sheath, color
black RAL 9005
External cable diameter D
4.8 mm ±0.2 mm
Minimum bending radius, fixed installation
5 x D
Outer sheath, material
PVC
Material conductor insulation
PVC
Conductor material
Bare Cu litz wires
Insulation resistance
≥ 20 MΩ*km
Conductor resistance
39 Ω/km (at 20 °C)
Nominal voltage, cable
300 V
Test voltage, cable
1200 V
Flame resistance
DIN VDE 0482
Flame resistance
DIN EN 50265-2-1
Resistance to oil
largely oil-resistant
Ambient temperature (operation)
-40 °C - 80 °C (cable, fixed installation)
Ambient temperature (operation)
-5 °C - 80 °C (cable, flexible installation)

PUR halogen-free yellow [240]

Cable type
PUR halogen-free yellow
Cable type (abbreviation)
240
Cable abbreviation
Li9Y11Y
UL AWM style
20549 (80°C/300 V)
Conductor cross section
3x 0.5 mm²
AWG signal line
20
Conductor structure signal line
28x 0.15 mm
Core diameter including insulation
1.46 mm ±0.02 mm
Thickness, insulation
≥ 0.21 mm
Wire colors
black 1, black 2, green/yellow
Overall twist
3 wires, twisted
External sheath, color
yellow
Outer sheath thickness
approx. 0.6 mm
External cable diameter D
4.5 mm ±0.15 mm
Cable weight
30 kg/km
Outer sheath, material
PUR
Material conductor insulation
PP
Conductor material
Bare Cu litz wires
Insulation resistance
≥ 10 GΩ*km
Conductor resistance
≤ 39 Ω/km
Nominal voltage, cable
≤ 300 V
Test voltage, cable
≥ 3000 V
Flame resistance
in accordance with DIN UL-Style 20549
Halogen-free
in accordance with DIN VDE 0472 part 815
Ambient temperature (operation)
-15 °C - 80 °C (cable, fixed installation)

PUR irradiated halogen-free orange [150]

Cable type
PUR irradiated halogen-free orange
Cable type (abbreviation)
150
Cable abbreviation
Li12Y11X
Conductor cross section
3x 0.5 mm² (Signal line)
AWG signal line
20
Conductor structure signal line
28x 0.15 mm
Core diameter including insulation
1.46 mm ±0.02 mm (Signal line)
Thickness, insulation
≥ 0.21 mm (Core insulation)
Thickness, insulation
approx. 0.6 mm (Outer cable sheath)
Wire colors
black 1, black 2, green/yellow
Overall twist
3 wires, twisted
External sheath, color
orange RAL 2003
External cable diameter D
4.5 mm ±0.15 mm
Number of bending cycles
5000000
Bending radius
45 mm
Traversing path
10 m
Traversing rate
3 m/s
Cable weight
31 kg/km
Outer sheath, material
PUR
Material conductor insulation
TPE-E
Conductor material
Bare Cu litz wires
Insulation resistance
≥ 100 MΩ*km (at 20 °C)
Conductor resistance
max. 39 Ω/km (at 20 °C)
Nominal voltage, cable
≤ 300 V
Test voltage, cable
≥ 3000 V
Special properties
Silicone-free
Special properties
Irradiated
Flame resistance
in accordance with DIN UL-Style 20549
Halogen-free
in accordance with DIN VDE 0472 part 815
Ambient temperature (operation)
-25 °C - 80 °C (cable, fixed installation)
Ambient temperature (operation)
-5 °C - 80 °C (cable, flexible installation)

Dimensions

Length of cable
Free input (0.2 - 40.0 m)
Central screw valve connector
M3 x 29

PVC, 0.75 mm², black [534]

Conductor cross section
3x 0.75 mm² (Signal line)
AWG signal line
18
Conductor structure signal line
24x 0.20 mm
Core diameter including insulation
1.7 mm ±0.1 mm
Wire colors
black 1, black 2, green/yellow
Overall twist
3 wires, twisted
External sheath, color
black
External cable diameter D
5.3 mm ±0.2 mm
Minimum bending radius, fixed installation
5 x D
Outer sheath, material
PVC
Material conductor insulation
PVC
Conductor material
Bare Cu litz wires
Insulation resistance
min. 20 MΩ*km (at 20 °C)
Conductor resistance
26 Ω/km (at 20 °C)
Nominal voltage, cable
300 V
Test voltage, cable
1200 V
Flame resistance
DIN VDE 0482
Flame resistance
DIN EN 50265-2-1
Flame resistance
in acc. to UL VW1
Resistance to oil
in accordance with DIN EN 60811-2-1
Ambient temperature (operation)
-40 °C - 80 °C (cable, fixed installation)
Ambient temperature (operation)
-5 °C - 80 °C (cable, flexible installation)

Material

Flammability rating according to UL 94
HB
Contact material
CuSn
Contact surface material
Ni/Au
Contact carrier material
TPU GF
Material of grip body
TPU
Valve plug contact material
CuSn
Valve plug contact surface material
Sn
Valve plug contact insert material
PA 6.6
Material housing valve plug
TPU
Material, knurls
Zinc die-cast, nickel-plated
Sealing material
TPU (Seal molded)

PUR/PVC, 0.75 mm², black [116]

Cable type
PUR/PVC, 0.75 mm², black
Cable type (abbreviation)
116
Cable abbreviation
LiYY11Y
UL AWM style
20549
Conductor cross section
3x 0.75 mm²
AWG signal line
18
Conductor structure signal line
24x 0.20 mm
Core diameter including insulation
1.7 mm ±0.05 mm
Wire colors
black 1, black 2, green/yellow
Overall twist
3 wires, twisted
External sheath, color
black RAL 9005
External cable diameter D
5.8 mm ±0.2 mm
Minimum bending radius, flexible installation
10 x D
Number of bending cycles
1000000
Traversing rate
2 m/s
Acceleration
2.5 m/s²
Outer sheath, material
PUR
Material, inner sheath
PVC
Material conductor insulation
PVC
Conductor material
Bare Cu litz wires
Insulation resistance
≥ 20 MΩ*km
Conductor resistance
26 Ω/km (at 20 °C)
Nominal voltage, cable
300 V
Test voltage, cable
1200 V
Special properties
flexible
Flame resistance
DIN VDE 0482
Flame resistance
DIN EN 50265-2-1
Flame resistance
in acc. with UL FT-2
Other resistance
Low adhesion
Ambient temperature (operation)
-40 °C - 80 °C (cable, fixed installation)
Ambient temperature (operation)
-5 °C - 80 °C (cable, flexible installation)

PUR halogen-free black [PUR]

Cable type
PUR halogen-free black
Cable type (abbreviation)
PUR
Cable abbreviation
Li9Y11Y-HF
UL AWM style
20549
Conductor cross section
3x 0.5 mm²
AWG signal line
20
Conductor structure signal line
28x 0.15 mm
Core diameter including insulation
1.5 mm ±0.05 mm (Signal line)
Wire colors
black 1, black 2, green/yellow
Overall twist
3 wires, twisted
External sheath, color
black-gray RAL 7021
External cable diameter D
4.5 mm ±0.2 mm
Smallest bending radius, fixed installation
22.5 mm
Number of bending cycles
15000000
Bending radius
50 mm
Traversing path
0.9 m
Traversing rate
5 m/s
Acceleration
30 m/s²
Outer sheath, material
PUR
Material conductor insulation
PP
Conductor material
Bare Cu litz wires
Insulation resistance
min. 20 MΩ*km
Conductor resistance
39 Ω/km (at 20 °C)
Nominal voltage, cable
≤ 300 V
Test voltage, cable
≥ 1200 V
Flame resistance
according to DIN VDE 0482
Flame resistance
According to DIN EN 50265-2-1
Halogen-free
in accordance with DIN VDE 0472 part 815
Other resistance
largely oil-resistant
Other resistance
partly UV-resistant in accordance with DIN EN ISO 4892-2-A
Ambient temperature (operation)
-40 °C - 80 °C (cable, fixed installation)
Ambient temperature (operation)
-20 °C - 80 °C (cable, flexible installation)

PUR, halogen-free, highly stranded, resistant to welding sparks, gray [800]

Note
Due to the extremely robust outer sheath, this cable should only be stripped in 5 cm increments.
Cable abbreviation
LiF9Y11Y
UL AWM style
20549
Conductor cross section
3x 0.5 mm² (Signal line)
AWG signal line
20
Conductor structure signal line
28x 0.15 mm
Core diameter including insulation
1.5 mm ±0.05 mm (Signal line)
Wire colors
black 1, black 2, green/yellow
Overall twist
Wires twisted in layers
External sheath, color
gray RAL 7001
External cable diameter D
4.5 mm ±0.2 mm
Minimum bending radius, fixed installation
5 x D
Minimum bending radius, flexible installation
5 x D
Number of bending cycles
15000000
Bending radius
50 mm
Traversing path
0.9 m
Traversing rate
5 m/s
Acceleration
30 m/s²
Torsion force
± 360 °/m
Cable weight
31 kg/km
Outer sheath, material
PUR
Material conductor insulation
PP
Conductor material
Bare Cu litz wires
Insulation resistance
≥ 20 MΩ*km
Conductor resistance
39 Ω/km (at 20 °C)
Nominal voltage, cable
300 V
Test voltage, cable
1200 V
Special properties
Cable jacket is welding spark-resistant, recyclable, matt, low-adhesion, abrasion-resistant, flame-retardant, and self-extinguishing
Special properties
Free from silicone and cadmium
Special properties
Free of substances which would hinder coating with paint or varnish
Flame resistance
in accordance with UL 758/1581 FT2
Halogen-free
The cable is halogen-free
Resistance to oil
in accordance with DIN EN 60811-2-1
Other resistance
Highly resistant to acids, alkaline solutions and solvents
Ambient temperature (operation)
-40 °C - 80 °C (cable, fixed installation)
Ambient temperature (operation)
-25 °C - 80 °C (cable, flexible installation)

PVC gray [500]

Cable type
PVC gray
Cable type (abbreviation)
500
Cable abbreviation
LiYY
Conductor cross section
3x 0.5 mm² (Signal line)
AWG signal line
20
Conductor structure signal line
16x 0.20 mm
Core diameter including insulation
1.5 mm ±0.05 mm (Signal line)
Wire colors
black 1, black 2, green/yellow
Overall twist
Wires twisted in layers
External sheath, color
gray RAL 7001
External cable diameter D
4.8 mm ±0.2 mm
Smallest bending radius, fixed installation
24 mm
Outer sheath, material
PVC
Material conductor insulation
PVC
Conductor material
Bare Cu litz wires
Insulation resistance
min. 20 MΩ*km
Conductor resistance
39 Ω/km (at 20 °C)
Nominal voltage, cable
300 V
Test voltage, cable
1200 V
Flame resistance
DIN EN 50265-2-1
Resistance to oil
largely oil-resistant
Ambient temperature (operation)
-40 °C - 80 °C (cable, fixed installation)
Ambient temperature (operation)
-5 °C - 80 °C (cable, flexible installation)

Ambient conditions

Ambient temperature (operation)
-25 °C - 90 °C (Plug / socket)
Ambient temperature (operation)
-20 °C - 85 °C (valve plug)
Degree of protection
IP65
Degree of protection
IP67

Line characteristics

Note
This item is a sensor/actuator cable with a freely selectable cable type. The technical data for all possible cable types is listed in the table below.

Environmental Product Compliance

China RoHS
Environmentally Friendly Use Period = 50 years
China RoHS
For details about hazardous substances go to tab 'Downloads', Category 'Manufacturer's declaration'

PUR/PVC 0.75 mm² gray [117]

Cable abbreviation
LiYY11Y
UL AWM style
20549
Conductor cross section
3x 0.75 mm² (Signal line)
AWG signal line
18
Conductor structure signal line
24x 0.20 mm
Core diameter including insulation
1.7 mm ±0.05 mm (Signal line)
Wire colors
black 1, black 2, green/yellow
Overall twist
Wires twisted in layers
External sheath, color
gray RAL 7001
External cable diameter D
5.8 mm ±0.2 mm
Smallest bending radius, fixed installation
29 mm
Smallest bending radius, movable installation
58 mm
Number of bending cycles
1000000
Traversing rate
2 m/s
Acceleration
2.5 m/s²
Outer sheath, material
PUR
Material, inner sheath
PVC
Material conductor insulation
PVC
Conductor material
Bare Cu litz wires
Insulation resistance
≥ 20 MΩ*km
Conductor resistance
26 Ω/km (at 20 °C)
Nominal voltage, cable
300 V
Test voltage, cable
1200 V
Flame resistance
according to DIN VDE 0482
Flame resistance
According to DIN EN 50265-2-1
Flame resistance
in acc. with UL FT-2
Ambient temperature (operation)
-40 °C - 80 °C (cable, fixed installation)
Ambient temperature (operation)
-5 °C - 80 °C (cable, flexible installation)

Standards and Regulations

Standards/specifications
M12 connector IEC 61076-2-101
Flammability rating according to UL 94
HB