Phoenix Contact
1523052
Sensor/actuator cable - SAC-8P-M12MS-M12FR SH/.../... - 1523052...
- Part Number
- 1523052
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Send request for price
1
Payment methods:
Additional Information
- Part Number
- 1523052
- ETIM
- Group Code : EG000026
- Group Description : Sensors
- Class Description : Sensor-actuator patch cord
- Class Code : EC001855
- Version : 7
PUR halogen-free gray [280]
- Cable type
- PUR halogen-free gray
- Cable type (abbreviation)
- 280
- Cable abbreviation
- LiY-FC11Y
- UL AWM style
- 20549 / 10493 (80°C/300 V)
- Conductor cross section
- 8x 0.25 mm² (Signal line)
- AWG signal line
- 24
- Conductor structure signal line
- 32x 0.10 mm
- Core diameter including insulation
- 1.17 mm ±0.02 mm
- Thickness, insulation
- approx. 0.2 mm
- Wire colors
- Brown, white, green, yellow, gray, pink, blue, red
- Overall twist
- 8 wires around filler to the core
- Shielding
- Tinned copper braided shield
- Optical shield covering
- 85 %
- External sheath, color
- gray RAL 7001
- Outer sheath thickness
- approx. 0.5 mm
- External cable diameter D
- 5.9 mm ±0.2 mm
- Minimum bending radius, fixed installation
- 5 x D
- Minimum bending radius, flexible installation
- 10 x D
- Number of bending cycles
- 2000000
- Minimum bending radius, drag chain applications
- 10 x D
- Traversing path
- 10 m
- Traversing rate
- 3 m/s
- Acceleration
- 10 m/s²
- Cable weight
- 53 kg/km
- Outer sheath, material
- PUR
- Material conductor insulation
- PP
- Conductor material
- Bare Cu litz wires
- Insulation resistance
- ≥ 1 GΩ*km (at 20 °C)
- Conductor resistance
- ≤ 78 Ω/km (at 20 °C)
- Nominal voltage, cable
- ≤ 300 V AC
- Test voltage, cable
- ≥ 3000 V AC (Spark test)
- Test voltage Core/Shield
- ≥ 2000 V AC (for 60 s)
- Special properties
- Flexible cable conduit capable
- Flame resistance
- in acc. with UL FT-2
- Flame resistance
- according to UL 758/1581 (horizontal)
- Flame resistance
- in accordance with UL 758/1581 FT2
- Flame resistance
- According to DIN EN 60332-2-2 (20 s)
- Halogen-free
- in accordance with DIN VDE 0472 part 815
- Halogen-free
- in accordance with DIN EN 50267-2-1
- Other resistance
- hydrolysis and microbe resistant
- Other resistance
- Resistant to salt water
- Other resistance
- Low adhesion
- Ambient temperature (operation)
- -40 °C - 80 °C (cable, fixed installation)
- Ambient temperature (operation)
- -25 °C - 80 °C (cable, flexible installation)
Dimensions
- Length of cable
- Free input (0.2 - 40.0 m)
Material
- Flammability rating according to UL 94
- HB
- Contact material
- CuZn
- Contact surface material
- Ni/Au
- Contact carrier material
- TPU GF
- Material of grip body
- TPU, hardly inflammable, self-extinguishing
- Material, knurls
- Zinc die-cast, nickel-plated
- Sealing material
- NBR
PUR halogen-free black [PUR]
- Cable type
- PUR halogen-free black
- Cable type (abbreviation)
- PUR
- Cable abbreviation
- LiF9YC11Y
- UL AWM style
- 20549 / 10493 (80°C/300 V)
- Conductor cross section
- 8x 0.25 mm² (Signal line)
- AWG signal line
- 24
- Conductor structure signal line
- 32x 0.10 mm
- Core diameter including insulation
- 1.17 mm ±0.02 mm
- Thickness, insulation
- approx. 0.2 mm
- Wire colors
- Brown, white, green, yellow, gray, pink, blue, red
- Overall twist
- 8 wires around filler to the core
- Shielding
- Tinned copper braided shield
- Optical shield covering
- 85 %
- External sheath, color
- black-gray RAL 7021
- Outer sheath thickness
- approx. 0.5 mm
- External cable diameter D
- 5.9 mm ±0.2 mm
- Minimum bending radius, fixed installation
- 5 x D
- Minimum bending radius, flexible installation
- 10 x D
- Number of bending cycles
- 2000000
- Minimum bending radius, drag chain applications
- 10 x D
- Traversing path
- 10 m
- Traversing rate
- 3 m/s
- Acceleration
- 10 m/s²
- Cable weight
- 53 kg/km
- Outer sheath, material
- PUR
- Material conductor insulation
- PP
- Conductor material
- Bare Cu litz wires
- Insulation resistance
- ≥ 1 GΩ*km (at 20 °C)
- Conductor resistance
- ≤ 78 Ω/km (at 20 °C)
- Nominal voltage, cable
- ≤ 300 V AC
- Test voltage, cable
- ≥ 3000 V AC (Spark test)
- Test voltage Core/Shield
- ≥ 2000 V AC (for 60 s)
- Special properties
- Flexible cable conduit capable
- Flame resistance
- in acc. with UL FT-2
- Flame resistance
- according to UL 758/1581 (horizontal)
- Flame resistance
- in accordance with UL 758/1581 FT2
- Flame resistance
- According to DIN EN 60332-2-2 (20 s)
- Halogen-free
- in accordance with DIN VDE 0472 part 815
- Halogen-free
- in accordance with DIN EN 50267-2-1
- Other resistance
- hydrolysis and microbe resistant
- Other resistance
- Resistant to salt water
- Other resistance
- Low adhesion
- Other resistance
- partly UV-resistant in accordance with DIN EN ISO 4892-2-A
- Ambient temperature (operation)
- -40 °C - 80 °C (cable, fixed installation)
- Ambient temperature (operation)
- -25 °C - 80 °C (cable, flexible installation)
Ambient conditions
- Ambient temperature (operation)
- -25 °C - 90 °C (Plug / socket)
- Degree of protection
- IP65
- Degree of protection
- IP67
Line characteristics
- Note
- This item is a sensor/actuator cable with a freely selectable cable type. The technical data for all possible cable types is listed in the table below.
Environmental Product Compliance
- REACh SVHC
- Lead 7439-92-1
- China RoHS
- Environmentally Friendly Use Period = 50 years
- China RoHS
- For details about hazardous substances go to tab 'Downloads', Category 'Manufacturer's declaration'
Standards and Regulations
- Standards/specifications
- M12 connector IEC 61076-2-101
- Flammability rating according to UL 94
- HB
Other Categories
NanometersManometersFlowmetersSensorsAcceleration SensorsFiber Optic SensorsDetectorsUltrasonic SensorsTemperature & Humidity SensorsVibration SensorsLevel SensorsPressure SensorsProximity SensorsInductive SensorsMotion SensorsMagnetic Sensors GroupOptical SensorsCapacitive SensorsPhotoelectric SensorsPosition SensorsEncodersOther sensors and Accessories