Sensor/actuator box 1548354
1548354
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:

Additional Information

Part Number
1548354
UPC
4046356142823
Country of Origin
PL

Conductor data

Structure of individual litz in acc. with VDE 0295 / smallest wire diameter
Class 2-6
Wire insulation material
PVC / PE /PP
Wire diameter including insulation
0.7 mm - 1.3 mm
Minimum external conductor diameter
3.5 mm
Maximum external conductor diameter
6 mm
Tightening torque, union nut
2 Nm
Wrench size, union nut
13 mm
Conductor cross section flexible min.
0.14 mm²
Conductor cross section flexible max.
0.34 mm²
Conductor cross section AWG min.
26
Conductor cross section AWG max.
22

Pin assignment

Slot/position = Wire color or connection
1 / 4 (A) = 1 / 4
Slot/position = Wire color or connection
2 / 4 (A) = 2 / 4
Slot/position = Wire color or connection
3 / 4 (A) = 3 / 4
Slot/position = Wire color or connection
4 / 4 (A) = 4 / 4
Slot/position = Wire color or connection
1-4 / 1 (+ 48 V) = UN
Slot/position = Wire color or connection
1-4 / 3 (0 V) = 0 V

Ambient conditions

Degree of protection
IP65
Degree of protection
IP67
Degree of protection
IP69K
Ambient temperature (operation)
-30 °C - 80 °C

Insulation material

Housing material
PBT
Material of the moulding mass
PUR
Contact material
Steel/copper
Contact surface material
Sn
Contact carrier material
PA 6.6
Material of contact, master cable side
CU alloy
Material of contact surface, master cable side
Gold-plated
Material of the contact carrier on the master cable side
PA 6.6 V0

Master cable data/connection data

Connection method
Pluggable screw connection
Conductor cross section min. (signal)
0.14 mm²
Conductor cross section max. (signal)
1.5 mm²
Conductor cross section AWG min. (signal)
26
Conductor cross section AWG max. (signal)
16
Stripping length (signal)
7 mm
Conductor cross section min. (energy)
0.14 mm²
Conductor cross section max. (energy)
1.5 mm²
Conductor cross section AWG min. (energy)
26
Conductor cross section AWG max. (energy)
16
External cable diameter min.
7 mm
External cable diameter max.
12 mm
Stripping length
50 mm (Master cable)
Tightening torque, cover screw
0.35 Nm
Tightening torque, union nut
2.5 Nm
Tightening torque of mounting screw for fixing the housing
0.5 Nm

Environmental Product Compliance

REACh SVHC
Lead 7439-92-1

Standards and Regulations

Connection in acc. with standard
CUL
Flammability rating according to UL 94
V0