PUR halogen-free gray [280]

Cable type
PUR halogen-free gray
Cable type (abbreviation)
280
Cable abbreviation
LiY-FC11Y
UL AWM style
20549 / 10493 (80°C/300 V)
Conductor cross section
8x 0.25 mm² (Signal line)
AWG signal line
24
Conductor structure signal line
32x 0.10 mm
Core diameter including insulation
1.17 mm ±0.02 mm
Thickness, insulation
approx. 0.2 mm
Wire colors
Brown, white, green, yellow, gray, pink, blue, red
Overall twist
8 wires around filler to the core
Shielding
Tinned copper braided shield
Optical shield covering
85 %
External sheath, color
gray RAL 7001
Outer sheath thickness
approx. 0.5 mm
External cable diameter D
5.9 mm ±0.2 mm
Minimum bending radius, fixed installation
5 x D
Minimum bending radius, flexible installation
10 x D
Number of bending cycles
2000000
Minimum bending radius, drag chain applications
10 x D
Traversing path
10 m
Traversing rate
3 m/s
Acceleration
10 m/s²
Cable weight
53 kg/km
Outer sheath, material
PUR
Material conductor insulation
PP
Conductor material
Bare Cu litz wires
Insulation resistance
≥ 1 GΩ*km (at 20 °C)
Conductor resistance
≤ 78 Ω/km (at 20 °C)
Nominal voltage, cable
≤ 300 V AC
Test voltage, cable
≥ 3000 V AC (Spark test)
Test voltage Core/Shield
≥ 2000 V AC (for 60 s)
Special properties
Flexible cable conduit capable
Flame resistance
in acc. with UL FT-2
Flame resistance
according to UL 758/1581 (horizontal)
Flame resistance
in accordance with UL 758/1581 FT2
Flame resistance
According to DIN EN 60332-2-2 (20 s)
Halogen-free
in accordance with DIN VDE 0472 part 815
Halogen-free
in accordance with DIN EN 50267-2-1
Other resistance
hydrolysis and microbe resistant
Other resistance
Resistant to salt water
Other resistance
Low adhesion
Ambient temperature (operation)
-40 °C - 80 °C (cable, fixed installation)
Ambient temperature (operation)
-25 °C - 80 °C (cable, flexible installation)

Dimensions

Length of cable
Free input (0.2 - 40.0 m)

Material

Flammability rating according to UL 94
HB
Contact material
CuSn
Contact surface material
Ni/Au
Contact carrier material
TPU GF
Material of grip body
TPU, hardly inflammable, self-extinguishing
Material, knurls
Zinc die-cast, nickel-plated
Sealing material
NBR

PUR halogen-free black [PUR]

Cable type
PUR halogen-free black
Cable type (abbreviation)
PUR
Cable abbreviation
LiF9YC11Y
UL AWM style
20549 / 10493 (80°C/300 V)
Conductor cross section
8x 0.25 mm² (Signal line)
AWG signal line
24
Conductor structure signal line
32x 0.10 mm
Core diameter including insulation
1.17 mm ±0.02 mm
Thickness, insulation
approx. 0.2 mm
Wire colors
Brown, white, green, yellow, gray, pink, blue, red
Overall twist
8 wires around filler to the core
Shielding
Tinned copper braided shield
Optical shield covering
85 %
External sheath, color
black-gray RAL 7021
Outer sheath thickness
approx. 0.5 mm
External cable diameter D
5.9 mm ±0.2 mm
Minimum bending radius, fixed installation
5 x D
Minimum bending radius, flexible installation
10 x D
Number of bending cycles
2000000
Minimum bending radius, drag chain applications
10 x D
Traversing path
10 m
Traversing rate
3 m/s
Acceleration
10 m/s²
Cable weight
53 kg/km
Outer sheath, material
PUR
Material conductor insulation
PP
Conductor material
Bare Cu litz wires
Insulation resistance
≥ 1 GΩ*km (at 20 °C)
Conductor resistance
≤ 78 Ω/km (at 20 °C)
Nominal voltage, cable
≤ 300 V AC
Test voltage, cable
≥ 3000 V AC (Spark test)
Test voltage Core/Shield
≥ 2000 V AC (for 60 s)
Special properties
Flexible cable conduit capable
Flame resistance
in acc. with UL FT-2
Flame resistance
according to UL 758/1581 (horizontal)
Flame resistance
in accordance with UL 758/1581 FT2
Flame resistance
According to DIN EN 60332-2-2 (20 s)
Halogen-free
in accordance with DIN VDE 0472 part 815
Halogen-free
in accordance with DIN EN 50267-2-1
Other resistance
hydrolysis and microbe resistant
Other resistance
Resistant to salt water
Other resistance
Low adhesion
Other resistance
partly UV-resistant in accordance with DIN EN ISO 4892-2-A
Ambient temperature (operation)
-40 °C - 80 °C (cable, fixed installation)
Ambient temperature (operation)
-25 °C - 80 °C (cable, flexible installation)

Ambient conditions

Ambient temperature (operation)
-25 °C - 90 °C (Plug / socket)
Degree of protection
IP65
Degree of protection
IP67

Line characteristics

Note
This item is a sensor/actuator cable with a freely selectable cable type. The technical data for all possible cable types is listed in the table below.

Environmental Product Compliance

REACh SVHC
Lead 7439-92-1
China RoHS
Environmentally Friendly Use Period = 50 years
China RoHS
For details about hazardous substances go to tab 'Downloads', Category 'Manufacturer's declaration'

Standards and Regulations

Standards/specifications
M12 connector IEC 61076-2-101
Flammability rating according to UL 94
HB