Bus system cable - SAC-4P-M12MSD/ 0,3-931/M12FSD - 1569508
1569508
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:

Additional Information

Part Number
1569508
UPC
4046356336413
Country of Origin
PL
ETIM
Group Code : EG000037
Group Description : Data and telecommunication
Class Description : Patch cord copper (twisted pair)
Class Code : EC001262
Version : 7

Dimensions

Length of cable
0.3 m

Material

Flammability rating according to UL 94
V0
Contact material
CuSn
Contact surface material
Ni/Au
Contact carrier material
PA 6.6
Material of grip body
TPU, hardly inflammable, self-extinguishing
Material, knurls
Zinc die-cast, nickel-plated
Sealing material
NBR

Ambient conditions

Ambient temperature (operation)
-25 °C - 90 °C (Plug / socket)
Degree of protection
IP65
Degree of protection
IP67

Environmental Product Compliance

REACh SVHC
Lead 7439-92-1
China RoHS
Environmentally Friendly Use Period = 50 years
China RoHS
For details about hazardous substances go to tab 'Downloads', Category 'Manufacturer's declaration'

Standards and Regulations

Flammability rating according to UL 94
V0

Cable

Cable abbreviation
02YS(ST)C11Y
UL AWM style
20963 (80°C/30 V)
Cable structure
2x2xAWG26/7; SF/UTP
Conductor cross section
2x 2x 0.14 mm²
AWG signal line
26
Conductor structure signal line
7x 0.16 mm
Core diameter including insulation
0.98 mm
Wire colors
white/orange-orange, white/green-green
Twisted pairs
2 cores to the pair
Overall twist
Two pairs with two fillers to the core
Shielding
Aluminum-coated foil, tinned copper braided shield
Optical shield covering
70 %
External sheath, color
water blue RAL 5021
Outer sheath thickness
1.2 mm
External cable diameter D
6.4 mm ±0.2 mm
Minimum bending radius, fixed installation
4 x D
Minimum bending radius, flexible installation
8 x D
Cable weight
42 kg/km
Tensile strength GRP
≤ 80 N
Outer sheath, material
PUR
Material conductor insulation
Foamed PE
Conductor material
Bare Cu litz wires
Standards/specifications
Electrical requirements EN 50288-2-2
Insulation resistance
≥ 500 MΩ*km
Loop resistance
≤ 290.00 Ω/km
Cable capacity
approx. 45 nF/km (at 1 kHz)
Wave impedance
100 Ω ±5 Ω (at 100 MHz)
Near end crosstalk attenuation (NEXT)
65.3 dB (with 1 MHz)
Near end crosstalk attenuation (NEXT)
56.3 dB (at 4 МHz)
Near end crosstalk attenuation (NEXT)
50.3 dB (at 10 MHz)
Near end crosstalk attenuation (NEXT)
47.2 dB (at 16 MHz)
Near end crosstalk attenuation (NEXT)
45.8 dB (at 20 МHz)
Near end crosstalk attenuation (NEXT)
42.9 dB (at 31.25 МHz)
Near end crosstalk attenuation (NEXT)
38.4 dB (at 62.5 МHz)
Near end crosstalk attenuation (NEXT)
35.3 dB (at 100 MHz)
Attenuation
3.2 dB (with 1 MHz)
Attenuation
6 dB (at 4 МHz)
Attenuation
9.5 dB (at 10 MHz)
Attenuation
12.1 dB (at 16 MHz)
Attenuation
13.6 dB (at 20 МHz)
Attenuation
17.1 dB (at 31.25 МHz)
Attenuation
24.8 dB (at 62.5 МHz)
Attenuation
32 dB (at 100 MHz)
Return Loss
23 dB (at 4 МHz)
Return Loss
24.1 dB (at 8 МHz)
Return Loss
25 dB (at 10 MHz)
Return Loss
25 dB (at 16 MHz)
Return Loss
25 dB (at 20 МHz)
Return Loss
23.6 dB (at 31.25 МHz)
Return Loss
21.5 dB (at 62.5 МHz)
Return Loss
20.1 dB (at 100 MHz)
Signal runtime
5.3 ns/m
Coupling resistance
≤ 100.00 mΩ/m (at 10 MHz)
Nominal voltage, cable
≤ 100 V (Peak value, not for high-power applications)
Test voltage Core/Core
700 V (50 Hz, 1 min.)
Test voltage Core/Shield
700 V (50 Hz, 1 min.)
Current carrying capacity of cable
2 A (according to DIN VDE 0891-1)
Flame resistance
according to IEC 60332-1-2
Flame resistance
in acc. to UL VW1
Halogen-free
according to IEC 60754-1
Resistance to oil
according to EN 60811-2-1
Ambient temperature (operation)
-40 °C - 80 °C (cable, fixed installation)
Ambient temperature (operation)
-20 °C - 80 °C (cable, flexible installation)