PVC yellow 105 °C [542]

Cable type
PVC yellow 105 °C
Cable type (abbreviation)
542
Conductor cross section
0.34 mm²
AWG signal line
22
Conductor structure signal line
42x 0.10 mm
Core diameter including insulation
1.55 mm ±0.05 mm
Thickness, insulation
≥ 0.38 mm (Core insulation)
Thickness, insulation
≥ 0.76 mm (Outer cable sheath)
Wire colors
Brown, white, blue, black, gray
Overall twist
5 wires around filler to the core
External sheath, color
yellow
External cable diameter D
5.9 mm ±0.2 mm
Cable weight
50 kg/km
Outer sheath, material
PVC
Material conductor insulation
PVC
Conductor material
Bare Cu litz wires
Insulation resistance
≥ 100 MΩ*km (at 20 °C)
Conductor resistance
max. 58 Ω/km (at 20 °C)
Nominal voltage, cable
≤ 300 V
Test voltage, cable
≥ 3000 V
Flame resistance
in accordance with UL-Style 2517

PUR halogen-free gray [280]

Cable type
PUR halogen-free gray
Cable type (abbreviation)
280
Conductor cross section
0.34 mm²
AWG signal line
22
AWG power supply
20
Conductor structure signal line
42x 0.10 mm
Conductor structure, voltage supply
28x 0.15 mm
Core diameter including insulation
1.55 mm (Signal line)
Core diameter including insulation
1.65 mm (Protective conductor)
Thickness, insulation
0.39 mm (Signal line)
Thickness, insulation
0.37 mm (Protective conductor)
Thickness, insulation
0.65 mm (Outer cable sheath)
Wire colors
brown, white, blue, black, green-yellow
Overall twist
5 wires around filler to the core
External sheath, color
gray RAL 7001
External cable diameter
5.20 mm
Outer sheath, material
PUR
Material, filler
Fiberglass
Material conductor insulation
TPE
Conductor material
Bare Cu litz wires
Ambient temperature (operation)
-40 °C - 80 °C (cable, fixed installation)
Ambient temperature (operation)
-5 °C - 80 °C (cable, flexible installation)

PUR POWER 0.75 mm² black [186]

Cable type
PUR POWER 0.75 mm² black
Cable type (abbreviation)
186
Cable abbreviation
LiY11Y
Conductor cross section
5x 0.75 mm² (power line)
AWG signal line
18
Conductor structure signal line
42x 0.15 mm
Core diameter including insulation
1.7 mm ±0.05 mm
Thickness, insulation
≥ 0.23 mm (Core insulation)
Thickness, insulation
≥ 0.76 mm (Outer cable sheath)
Wire colors
Brown, white, blue, black, gray
Overall twist
5 wires around filler to the core
External sheath, color
black-gray RAL 7021
External cable diameter D
6.3 mm ±0.2 mm
Smallest bending radius, movable installation
63 mm
Number of bending cycles
2000000
Bending radius
63 mm
Traversing path
5 m
Traversing rate
3 m/s
Acceleration
5 m/s²
Cable weight
67 kg/km
Outer sheath, material
PUR
Material conductor insulation
PVC
Conductor material
Bare Cu litz wires
Insulation resistance
≥ 1 MΩ*km (at 20 °C)
Conductor resistance
max. 26 Ω/km (at 20 °C)
Nominal voltage, cable
≤ 300 V
Test voltage, cable
≥ 3000 V
Flame resistance
in accordance with DIN UL-Style 20549
Ambient temperature (operation)
-25 °C - 80 °C (cable, fixed installation)
Ambient temperature (operation)
-5 °C - 80 °C (cable, flexible installation)

Gray, highly flexible PUR [800]

Note
Due to the extremely robust outer sheath, this cable should only be stripped in 5 cm increments.
Cable type
Gray, highly flexible PUR
Cable type (abbreviation)
800
Cable abbreviation
LiF9Y11Y
UL AWM style
20549
Conductor cross section
5x 0.34 mm² (Signal line)
AWG signal line
22
Conductor structure signal line
42x 0.10 mm
Core diameter including insulation
1.3 mm ±0.05 mm (Signal line)
Wire colors
Black, brown,blue, white, gray
Overall twist
5 wires around filler to the core
External sheath, color
gray RAL 7001
External cable diameter D
5.1 mm ±0.2 mm
Minimum bending radius, fixed installation
4 x D
Minimum bending radius, flexible installation
7.5 x D
Number of bending cycles
10000000
Minimum bending radius, drag chain applications
7,5 x D
Traversing path
5 m
Traversing rate
3.3 m/s
Acceleration
5 m/s²
Number of bending cycles
15000000
Bending radius
50 mm
Traversing path
0.9 m
Traversing rate
5 m/s
Acceleration
30 m/s²
Torsion force
± 360 °/m (1 000 000 torsion cycles)
Cable weight
38 kg/km
Outer sheath, material
PUR
Material, filler
PE
Material conductor insulation
PP
Conductor material
Bare Cu litz wires
Insulation resistance
≥ 20 MΩ*km
Conductor resistance
approx. 53 Ω/km
Nominal voltage, cable
300 V
Test voltage, cable
2000 V
Special properties
Cable jacket is welding spark-resistant, recyclable, matt, low-adhesion, abrasion-resistant, flame-retardant, and self-extinguishing
Special properties
Free from silicone and cadmium
Special properties
Free of substances which would hinder coating with paint or varnish
Flame resistance
in accordance with UL 758/1581 FT2
Halogen-free
in accordance with DIN VDE 0472 part 815
Resistance to oil
in accordance with DIN EN 60811-2-1
Other resistance
Highly resistant to acids, alkaline solutions and solvents
Other resistance
Silicone-free
Ambient temperature (operation)
-40 °C - 80 °C (cable, fixed installation)
Ambient temperature (operation)
-25 °C - 80 °C (cable, flexible installation)

PVC black [PVC]

Cable type
PVC black
Cable type (abbreviation)
PVC
Cable abbreviation
LiYY
UL AWM style
2464 / 1729 (80°C/300 V)
Conductor cross section
5x 0.34 mm² (Signal line)
AWG signal line
22
Conductor structure signal line
42x 0.10 mm
Core diameter including insulation
1.45 mm ±0.02 mm
Thickness, insulation
≥ 0.23 mm (Core insulation)
Wire colors
brown, white, blue, black, green-yellow
Overall twist
5 wires around filler to the core
External sheath, color
black RAL 9005
Outer sheath thickness
≥ 0.76 mm
External cable diameter D
5.9 mm ±0.15 mm
Minimum bending radius, fixed installation
5 x D
Minimum bending radius, flexible installation
10 x D
Cable weight
51 kg/km
Outer sheath, material
PVC
Material conductor insulation
PVC
Conductor material
Bare Cu litz wires
Insulation resistance
≥ 200 MΩ*km (at 20 °C)
Conductor resistance
max. 58 Ω/km (at 20 °C)
Nominal voltage, cable
≤ 300 V
Test voltage, cable
≥ 3000 V
Flame resistance
As per UL-Style 2464
Flame resistance
according to UL 758/1581 FT1
Resistance to oil
According to DIN EN 60811-2-1, 168 h at 90°C
Ambient temperature (operation)
-40 °C - 80 °C (cable, fixed installation)
Ambient temperature (operation)
-25 °C - 80 °C (cable, flexible installation)

PUR halogen-free yellow [240]

Cable type
PUR halogen-free yellow
Cable type (abbreviation)
240
Cable abbreviation
Li9Y11Y
UL AWM style
20549 / 10493 (80°C/300 V)
Conductor cross section
5x 0.34 mm²
AWG signal line
22
Conductor structure signal line
42x 0.10 mm
Core diameter including insulation
1.27 mm ±0.02 mm
Thickness, insulation
≥ 0.21 mm
Wire colors
brown, white, blue, black, green-yellow
Overall twist
5 wires around filler to the core
Length of twist, overall twist
55 mm
External sheath, color
yellow
Outer sheath thickness
approx. 0.7 mm
External cable diameter D
5 mm ±0.15 mm
Minimum bending radius, fixed installation
5 x D
Minimum bending radius, flexible installation
10 x D
Number of bending cycles
4000000
Minimum bending radius, drag chain applications
10 x D
Traversing path
10 m
Traversing rate
3 m/s
Acceleration
10 m/s²
Cable weight
35 kg/km
Outer sheath, material
PUR
Material conductor insulation
PP
Conductor material
Bare Cu litz wires
Conductor resistance
≤ 58 Ω/km (at 20 °C)
Nominal voltage, cable
≤ 300 V
Test voltage, cable
≥ 3000 V
Flame resistance
in accordance with DIN UL-Style 20549
Flame resistance
in accordance with UL 758/1581 FT2
Halogen-free
in accordance with DIN VDE 0472 part 815
Resistance to oil
in accordance with DIN EN 60811-2-1
Other resistance
hydrolysis and microbe resistant
Other resistance
Resistant to salt water
Ambient temperature (operation)
-40 °C - 80 °C (cable, fixed installation)
Ambient temperature (operation)
-25 °C - 80 °C (cable, flexible installation)

PUR/PVC gray [100]

Cable type
PUR/PVC gray
Cable type (abbreviation)
100
Cable abbreviation
LiYY-11Y
Conductor cross section
0.34 mm²
AWG signal line
22
Conductor structure signal line
42x 0.10 mm
Core diameter including insulation
1.5 mm ±0.05 mm
Thickness, insulation
≥ 0.3 mm (Core insulation)
Thickness, insulation
≥ 0.38 mm (Outer cable sheath)
Thickness, insulation
approx. 0.35 mm (Inner sheath)
Wire colors
brown, white, blue, black, green-yellow
Overall twist
5 wires around filler to the core
External sheath, color
gray RAL 7001
External cable diameter D
5.9 mm ±0.2 mm
Smallest bending radius, fixed installation
29.5 mm
Smallest bending radius, movable installation
59 mm
Number of bending cycles
2000000
Bending radius
59 mm
Traversing path
5 m
Traversing rate
3 m/s
Cable weight
50 kg/km
Outer sheath, material
PUR
Material, inner sheath
PVC
Material, filler
PVC
Material conductor insulation
PVC
Conductor material
Bare Cu litz wires
Insulation resistance
≥ 100 MΩ*km (at 20 °C)
Conductor resistance
max. 58 Ω/km (at 20 °C)
Nominal voltage, cable
≤ 300 V
Test voltage, cable
≥ 3000 V
Flame resistance
As per UL-Style 2464
Ambient temperature (operation)
-25 °C - 80 °C (cable, fixed installation)
Ambient temperature (operation)
-5 °C - 80 °C (cable, flexible installation)

PUR irradiated halogen-free orange [150]

Cable type
PUR irradiated halogen-free orange
Cable type (abbreviation)
150
Cable abbreviation
D12YSL11X-JB
Conductor cross section
4x 0.34 mm² (Signal line)
Conductor cross section
1x 0.5 mm² (PE connection)
AWG signal line
22
AWG power supply
20
Conductor structure signal line
42x 0.10 mm
Conductor structure, voltage supply
24x 0.15 mm
Wire colors
Brown, blue, black, white, green/yellow
Overall twist
5 cores, twisted
External sheath, color
orange RAL 2003
External cable diameter D
5.2 mm ±0.2 mm
Smallest bending radius, fixed installation
min. 20 mm
Smallest bending radius, movable installation
min. 30 mm
Number of bending cycles
5000000
Bending radius
52 mm
Traversing path
10 m
Traversing rate
3 m/s
Outer sheath, material
PUR
Material conductor insulation
PE
Conductor material
Bare Cu litz wires
Conductor resistance
≤ 57.5 Ω/km (with 0.34 mm² conductor cross section)
Conductor resistance
≤ 39 Ω/km (with 0.5 mm² conductor cross section)
Nominal voltage, cable
250 V (AC)
Test voltage, cable
2000 V (50 Hz, 5 minutes)
Special properties
Silicone-free
Special properties
Irradiated
Flame resistance
DIN VDE 0472 part 804, test type B
Halogen-free
The cable is halogen-free
Other resistance
hydrolysis and microbe resistant
Other resistance
UV resistant
Other resistance
Resistant to welding splashes
Ambient temperature (operation)
-50 °C - 105 °C (cable, fixed installation)
Ambient temperature (operation)
-40 °C - 105 °C (cable, flexible installation)

Dimensions

Length of cable
Free input (0.2 - 40.0 m)

Material

Flammability rating according to UL 94
HB
Contact material
CuSn
Contact surface material
Ni/Au
Contact carrier material
TPU GF
Material of grip body
TPU, hardly inflammable, self-extinguishing
Material, knurls
Zinc die-cast, nickel-plated
Sealing material
NBR

PVC yellow [540]

Cable type
PVC yellow
Cable type (abbreviation)
540
Cable abbreviation
LiFYY
Conductor cross section
0.34 mm²
AWG signal line
22
Conductor structure signal line
43x 0.10 mm
Core diameter including insulation
1.45 mm ±0.02 mm
Thickness, insulation
approx. 0.23 mm (Core insulation)
Thickness, insulation
approx. 0.76 mm (Outer cable sheath)
Wire colors
brown, white, blue, black, green-yellow
Overall twist
5 wires around filler to the core
Length of twist, overall twist
70 mm
External sheath, color
yellow
External cable diameter D
5.9 mm ±0.15 mm
Smallest bending radius, fixed installation
29.5 mm
Smallest bending radius, movable installation
59 mm
Outer sheath, material
PVC
Material, filler
PVC
Material conductor insulation
PVC
Conductor material
Bare Cu litz wires
Insulation resistance
≥ 1 MΩ*km (at 20 °C)
Conductor resistance
max. 58 Ω/km (at 20 °C)
Nominal voltage, cable
≤ 300 V (AC)
Test voltage, cable
3000 V
Flame resistance
As per UL-Style 2464
Flame resistance
according to UL 758/1581 FT1
Resistance to oil
in accordance with DIN EN 60811-2-1
Ambient temperature (operation)
-40 °C - 80 °C (cable, fixed installation)
Ambient temperature (operation)
-25 °C - 80 °C (cable, flexible installation)

PVC gray 5th conductor gray [520]

Cable abbreviation
LiYY
Conductor cross section
0.34 mm²
AWG signal line
22
Conductor structure signal line
42x 0.10 mm
Core diameter including insulation
1.45 mm ±0.02 mm
Thickness, insulation
≥ 0.23 mm (Core insulation)
Thickness, insulation
≥ 0.76 mm (Outer cable sheath)
Wire colors
Brown, white, blue, black, gray
Overall twist
5 wires around filler to the core
Length of twist, overall twist
55 mm
External sheath, color
gray RAL 7001
External cable diameter D
5.9 mm ±0.15 mm
Cable weight
54 kg/km
Outer sheath, material
PVC
Material, filler
PVC
Material conductor insulation
PVC
Conductor material
Bare Cu litz wires
Insulation resistance
≥ 1 GΩ*km (at 20 °C)
Conductor resistance
max. 58 Ω/km (at 20 °C)
Nominal voltage, cable
≤ 300 V
Test voltage, cable
≥ 3000 V
Flame resistance
As per UL-Style 2464
Ambient temperature (operation)
-25 °C - 80 °C (cable, fixed installation)
Ambient temperature (operation)
-5 °C - 80 °C (cable, flexible installation)

PUR halogen-free black [PUR]

Cable type
PUR halogen-free black
Cable type (abbreviation)
PUR
UL AWM style
20549
Conductor cross section
5x 0.34 mm² (Signal line)
AWG signal line
22
Conductor structure signal line
42x 0.10 mm
Core diameter including insulation
1.27 mm ±0.02 mm (Signal line)
Thickness, insulation
approx. 0.5 mm
Wire colors
brown, white, blue, black, green-yellow
External sheath, color
black-gray RAL 7021
External cable diameter D
4.55 mm ±0.15 mm
Smallest bending radius, fixed installation
23 mm
Smallest bending radius, movable installation
46 mm
Number of bending cycles
10000000
Bending radius
50 mm
Traversing path
10 m
Traversing rate
3 m/s
Acceleration
10 m/s²
Cable weight
33 kg/km
Outer sheath, material
PUR
Material conductor insulation
PP
Conductor material
Bare Cu litz wires
Insulation resistance
≥ 16 GΩ*km (at 20 °C)
Conductor resistance
max. 58 Ω/km (at 20 °C)
Nominal voltage, cable
300 V
Test voltage, cable
3000 V
Special properties
Flexible cable conduit capable
Special properties
Silicone-free
Special properties
Free of substances which would hinder coating with paint or varnish
Special properties
flexible
Flame resistance
in accordance with UL 758/1581 FT2
Flame resistance
DIN EN 60332-2-2 (20 s)
Halogen-free
in accordance with DIN VDE 0472 part 815
Resistance to oil
in accordance with DIN EN 60811-2-1
Other resistance
Highly resistant to acids, alkaline solutions and solvents
Other resistance
hydrolysis and microbe resistant
Other resistance
Resistant to salt water
Other resistance
partly UV-resistant in accordance with DIN EN ISO 4892-2-A
Ambient temperature (operation)
-40 °C - 80 °C (cable, fixed installation)
Ambient temperature (operation)
-25 °C - 80 °C (cable, flexible installation)

PVC gray [500]

Cable type
PVC gray
Cable type (abbreviation)
500
Cable abbreviation
LiYY
Conductor cross section
0.34 mm²
AWG signal line
22
Conductor structure signal line
42x 0.10 mm
Core diameter including insulation
1.45 mm ±0.02 mm
Thickness, insulation
≥ 0.23 mm (Core insulation)
Thickness, insulation
≥ 0.76 mm (Outer cable sheath)
Wire colors
brown, white, blue, black, green-yellow
Overall twist
5 wires around filler to the core
External sheath, color
gray RAL 7001
External cable diameter D
5.9 mm ±0.15 mm
Cable weight
51 kg/km
Outer sheath, material
PVC
Material, filler
PVC
Material conductor insulation
PVC
Conductor material
Bare Cu litz wires
Insulation resistance
≥ 1 GΩ*km (at 20 °C)
Conductor resistance
max. 58 Ω/km (at 20 °C)
Nominal voltage, cable
≤ 300 V (AC)
Test voltage, cable
≥ 3000 V (AC)
Flame resistance
As per UL-Style 2464
Flame resistance
according to UL 758/1581 FT1
Resistance to oil
in accordance with DIN EN 60811-2-1
Ambient temperature (operation)
-40 °C - 80 °C (cable, fixed installation)
Ambient temperature (operation)
-25 °C - 80 °C (cable, flexible installation)

PUR halogen-free orange [180]

Cable type
PUR halogen-free orange
Cable type (abbreviation)
180
Cable abbreviation
Li9YLi9Y-11Y
UL AWM style
20549
Conductor cross section
4x 0.34 mm² (Signal line)
Conductor cross section
1x 0.5 mm² (PE connection)
AWG signal line
22
AWG power supply
20
Conductor structure signal line
42x 0.10 mm
Conductor structure, voltage supply
28x 0.15 mm
Core diameter including insulation
1.27 mm ±0.02 mm (Signal line)
Core diameter including insulation
1.46 mm ±0.02 mm (PE connection)
Thickness, insulation
≥ 0.21 mm (Signal line)
Thickness, insulation
≥ 0.21 mm (PE connection)
Thickness, insulation
approx. 0.65 mm (Outer cable sheath)
Wire colors
brown, white, blue, black, green-yellow
Overall twist
5 wires around filler to the core
External sheath, color
orange RAL 2003
External cable diameter D
5 mm ±0.15 mm
Cable weight
36 kg/km
Outer sheath, material
PUR
Material conductor insulation
PP
Conductor material
Bare Cu litz wires
Insulation resistance
≥ 10 GΩ*km (at 20 °C)
Conductor resistance
≤ 58 Ω/km (Signal line)
Conductor resistance
≤ 39 Ω/km (PE connection)
Nominal voltage, cable
≤ 300 V
Test voltage, cable
≥ 3000 V
Flame resistance
in accordance with DIN UL-Style 20549
Halogen-free
in accordance with DIN VDE 0472 part 815
Ambient temperature (operation)
-25 °C - 80 °C (Cable)

Ambient conditions

Ambient temperature (operation)
-25 °C - 90 °C (Plug / socket)
Degree of protection
IP65
Degree of protection
IP67
Degree of protection
IP68

PUR, black, 5th conductor gray [115]

Cable type
PUR, black, 5th conductor gray
Cable type (abbreviation)
115
Cable abbreviation
Li9Y11Y-HF
UL AWM style
20549 / 10493 (80°C/300 V)
Conductor cross section
5x 0.34 mm²
AWG signal line
22
Conductor structure signal line
42x 0.10 mm
Core diameter including insulation
1.27 mm ±0.02 mm
Thickness, insulation
≥ 0.21 mm
Wire colors
Brown, white, blue, black, gray
Overall twist
5 cores, twisted
External sheath, color
black-gray RAL 7021
Outer sheath thickness
approx. 0.7 mm
External cable diameter D
5 mm ±0.15 mm
Minimum bending radius, fixed installation
5 x D
Minimum bending radius, flexible installation
10 x D
Number of bending cycles
4000000
Bending radius
50 mm
Traversing path
10 m
Traversing rate
3 m/s
Acceleration
10 m/s²
Cable weight
35 kg/km
Outer sheath, material
PUR
Material, filler
PP
Material conductor insulation
PP
Conductor material
Bare Cu litz wires
Conductor resistance
≤ 58 Ω/km
Nominal voltage, cable
≤ 300 V
Test voltage, cable
≥ 3000 V
Special properties
Flexible cable conduit capable
Special properties
Silicone-free
Special properties
Free of substances which would hinder coating with paint or varnish
Special properties
flexible
Flame resistance
in accordance with DIN UL-Style 20549
Flame resistance
in accordance with UL 758/1581 FT2
Halogen-free
in accordance with DIN VDE 0472 part 815
Resistance to oil
in accordance with DIN EN 60811-2-1
Other resistance
partly UV-resistant in accordance with DIN EN ISO 4892-2-A
Other resistance
hydrolysis and microbe resistant
Other resistance
Resistant to salt water
Other resistance
Low adhesion
Other resistance
abrasion-resistant
Ambient temperature (operation)
-40 °C - 80 °C (cable, fixed installation)
Ambient temperature (operation)
-25 °C - 80 °C (cable, flexible installation)

Line characteristics

Note
This item is a sensor/actuator cable with a freely selectable cable type. The technical data for all possible cable types is listed in the table below.

Environmental Product Compliance

China RoHS
Environmentally friendly use period: unlimited = EFUP-e
China RoHS
No hazardous substances above threshold values

Standards and Regulations

Standards/specifications
M12 connector IEC 61076-2-101
Flammability rating according to UL 94
HB

PVC black 5th conductor gray [515]

Cable abbreviation
LiYY
UL AWM style
2464 / 1729 (80°C/300 V)
Conductor cross section
5x 0.34 mm² (Signal line)
AWG signal line
22
Conductor structure signal line
42x 0.10 mm
Core diameter including insulation
1.45 mm ±0.02 mm
Thickness, insulation
≥ 0.23 mm (Core insulation)
Thickness, insulation
≥ 0.76 mm (Outer cable sheath)
Wire colors
Brown, white, blue, black, gray
Overall twist
5 wires around filler to the core
Length of twist, overall twist
60 mm
External sheath, color
black RAL 9005
External cable diameter D
5.9 mm ±0.15 mm
Minimum bending radius, fixed installation
5 x D
Minimum bending radius, flexible installation
10 x D
Cable weight
52 kg/km
Outer sheath, material
PVC
Material, filler
PP yarn
Material conductor insulation
PVC
Conductor material
Bare Cu litz wires
Insulation resistance
≥ 100 MΩ*km (at 20 °C)
Conductor resistance
≤ 58 Ω/km (at 20 °C)
Nominal voltage, cable
≤ 300 V AC
Test voltage, cable
≥ 3000 V AC
Flame resistance
According to UL 758/1581 (Cable Flame)
Flame resistance
according to UL 758/1581 FT1
Flame resistance
According to DIN EN 60332-1-2 (60 s)
Resistance to oil
according to DIN EN 60811-2-1, 168 h at 60 °C
Ambient temperature (operation)
-40 °C - 80 °C (cable, fixed installation)
Ambient temperature (operation)
-25 °C - 80 °C (cable, flexible installation)