Sensor/actuator cable - SAC-3P-M12FR SH/.../... - 1697454
1697454
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

Dimensions

Length of cable
Free input (0.2 - 40.0 m)
Stripping length of the free conductor end
50 mm

Material

Flammability rating according to UL 94
HB
Contact material
CuSn
Contact surface material
Ni/Au
Contact carrier material
TPU GF
Material of grip body
TPU, hardly inflammable, self-extinguishing
Material, knurls
Zinc die-cast, nickel-plated
Sealing material
NBR

PUR/PVC shielded, gray [100]

Cable type
PUR/PVC shielded, gray
Cable type (abbreviation)
100
Cable abbreviation
LiYV1CY11Y
Conductor cross section
0.34 mm²
AWG signal line
22
Conductor structure signal line
42x 0.10 mm
Core diameter including insulation
1.5 mm ±0.05 mm
Thickness, insulation
≥ 0.23 mm (Core insulation)
Thickness, insulation
≥ 0.38 mm (Outer cable sheath)
Thickness, insulation
approx. 0.3 mm (Inner sheath)
Wire colors
brown, blue, black
Overall twist
3 wires, twisted
Shielding
Braided copper wires
Optical shield covering
85 %
External sheath, color
gray RAL 7001
External cable diameter D
5.2 mm ±0.2 mm
Smallest bending radius, fixed installation
52 mm
Smallest bending radius, movable installation
52 mm
Number of bending cycles
2000000
Bending radius
52 mm
Traversing path
5 m
Traversing rate
3 m/s
Cable weight
38 kg/km
Outer sheath, material
PUR
Material, inner sheath
PVC
Material conductor insulation
PVC
Conductor material
Bare Cu litz wires
Insulation resistance
≥ 100 MΩ*km (at 20 °C)
Conductor resistance
max. 58 Ω/km (at 20 °C)
Nominal voltage, cable
≤ 300 V
Test voltage, cable
≥ 3000 V
Test voltage Core/Shield
≥ 2000 V
Ambient temperature (operation)
-25 °C - 80 °C (cable, fixed installation)
Ambient temperature (operation)
-5 °C - 80 °C (cable, flexible installation)

PUR halogen-free black [PUR]

Cable type
PUR halogen-free black
Cable type (abbreviation)
PUR
Cable abbreviation
Li9Y-Vl-C-Vl-11Y
UL AWM style
20549
Conductor cross section
3x 0.34 mm² (Signal line)
AWG signal line
22
Conductor structure signal line
42x 0.10 mm
Core diameter including insulation
1.27 mm ±0.02 mm (Signal line)
Thickness, insulation
≥ 0.21 mm (Core insulation)
Thickness, insulation
approx. 0.5 mm (Outer cable sheath)
Wire colors
brown, blue, black
Overall twist
3 wires, twisted
Shielding
Braided copper wires
Optical shield covering
80 %
External sheath, color
black-gray RAL 7021
External cable diameter D
4.65 mm ±0.15 mm
Smallest bending radius, fixed installation
23 mm
Smallest bending radius, movable installation
47 mm
Number of bending cycles
10000000
Bending radius
47 mm
Traversing path
10 m
Traversing rate
3 m/s
Acceleration
10 m/s²
Cable weight
31 kg/km
Outer sheath, material
PUR
Material conductor insulation
PP
Conductor material
Bare Cu litz wires
Insulation resistance
≥ 100 GΩ*km (at 20 °C)
Conductor resistance
max. 58 Ω/km (at 20 °C)
Nominal voltage, cable
≤ 300 V
Test voltage, cable
≥ 3000 V
Special properties
Flexible cable conduit capable
Special properties
Silicone-free
Special properties
Free of substances which would hinder coating with paint or varnish
Flame resistance
in accordance with UL 758/1581 FT2
Flame resistance
DIN EN 60332-2-2 (20 s)
Halogen-free
in accordance with DIN VDE 0472 part 815
Resistance to oil
in accordance with DIN EN 60811-2-1
Other resistance
Highly resistant to acids, alkaline solutions and solvents
Other resistance
hydrolysis and microbe resistant
Other resistance
partly UV-resistant in accordance with DIN EN ISO 4892-2-A
Ambient temperature (operation)
-40 °C - 80 °C (cable, fixed installation)
Ambient temperature (operation)
-25 °C - 80 °C (cable, flexible installation)

PVC gray [500]

Cable type
PVC gray
Cable type (abbreviation)
500
Conductor cross section
0.34 mm²
AWG signal line
22
Conductor structure signal line
42x 0.10 mm
Core diameter including insulation
1.4 mm ±0.02 mm
Thickness, insulation
≥ 0.23 mm (Core insulation)
Thickness, insulation
≥ 0.76 mm (Outer cable sheath)
Wire colors
brown, blue, black
Overall twist
3 wires, twisted
Shielding
Tinned copper braided shield
Optical shield covering
85 %
External sheath, color
gray RAL 7001
External cable diameter D
5.2 mm ±0.2 mm
Cable weight
40 kg/km
Outer sheath, material
PVC
Material conductor insulation
PVC
Conductor material
Bare Cu litz wires
Insulation resistance
≥ 1 GΩ*km (at 20 °C)
Conductor resistance
max. 58 Ω/km (at 20 °C)
Nominal voltage, cable
≤ 300 V
Test voltage, cable
≥ 3000 V
Ambient temperature (operation)
-25 °C - 80 °C (cable, fixed installation)
Ambient temperature (operation)
-5 °C - 80 °C (cable, flexible installation)

Ambient conditions

Ambient temperature (operation)
-25 °C - 90 °C (Plug / socket)
Degree of protection
IP65
Degree of protection
IP67

Line characteristics

Note
This item is a sensor/actuator cable with a freely selectable cable type. The technical data for all possible cable types is listed in the table below.

Environmental Product Compliance

China RoHS
Environmentally friendly use period: unlimited = EFUP-e
China RoHS
No hazardous substances above threshold values

PVC shielded black [PVC]

Cable type
PVC shielded black
Cable type (abbreviation)
PVC
Conductor cross section
3x 0.34 mm²
AWG signal line
22
Conductor structure signal line
42x 0.10 mm
Core diameter including insulation
1.4 mm ±0.02 mm
Thickness, insulation
≥ 0.23 mm (Core insulation)
Thickness, insulation
≥ 0.76 mm (Outer cable sheath)
Wire colors
brown, blue, black
Overall twist
3 wires, twisted
Shielding
Tinned copper braided shield
Optical shield covering
85 %
External sheath, color
black RAL 9005
External cable diameter D
5.2 mm ±0.2 mm
Cable weight
40 kg/km
Outer sheath, material
PVC
Material conductor insulation
PVC
Conductor material
Bare Cu litz wires
Insulation resistance
≥ 100 MΩ*km (at 20 °C)
Conductor resistance
max. 58 Ω/km (at 20 °C)
Nominal voltage, cable
≤ 300 V
Test voltage, cable
≥ 3000 V
Flame resistance
As per UL-Style 2464
Ambient temperature (operation)
-25 °C - 80 °C (cable, fixed installation)
Ambient temperature (operation)
-5 °C - 80 °C (cable, flexible installation)

Standards and Regulations

Standards/specifications
M12 connector IEC 61076-2-101
Flammability rating according to UL 94
HB