Phoenix Contact
2810874
Signal conditioner 2810874
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Send request for price
1
Payment methods:
Input data
- Number of inputs
- 1
- Configurable/programmable
- Yes, preconfigured
- Voltage input signal
- -50 mV - 50 mV
- Voltage input signal
- -60 mV - 60 mV
- Voltage input signal
- -75 mV - 75 mV
- Voltage input signal
- -80 mV - 80 mV
- Voltage input signal
- -100 mV - 100 mV
- Voltage input signal
- -120 mV - 120 mV
- Voltage input signal
- -150 mV - 150 mV
- Voltage input signal
- -200 mV - 200 mV
- Voltage input signal
- -240 mV - 240 mV
- Voltage input signal
- -300 mV - 300 mV
- Voltage input signal
- -500 mV - 500 mV
- Voltage input signal
- -600 mV - 600 mV
- Voltage input signal
- -750 mV - 750 mV
- Voltage input signal
- -800 mV - 800 mV
- Voltage input signal
- -1 V - 1 V
- Voltage input signal
- -1.2 V - 1.2 V
- Voltage input signal
- -1.5 V - 1.5 V
- Voltage input signal
- -2 V - 2 V
- Voltage input signal
- -2.4 V - 2.4 V
- Voltage input signal
- -3 V - 3 V
- Voltage input signal
- 0 mV - 50 mV
- Voltage input signal
- 0 mV - 60 mV
- Voltage input signal
- 0 mV - 75 mV
- Voltage input signal
- 0 mV - 80 mV
- Voltage input signal
- 0 mV - 100 mV
- Voltage input signal
- 0 mV - 120 mV
- Voltage input signal
- 0 mV - 150 mV
- Voltage input signal
- 0 mV - 200 mV
- Voltage input signal
- 0 mV - 240 mV
- Voltage input signal
- 0 mV - 300 mV
- Voltage input signal
- 0 mV - 500 mV
- Voltage input signal
- 0 mV - 600 mV
- Voltage input signal
- 0 mV - 750 mV
- Voltage input signal
- 0 mV - 800 mV
- Voltage input signal
- 0 V - 1 V
- Voltage input signal
- 0 V - 1.2 V
- Voltage input signal
- 0 V - 1.5 V
- Voltage input signal
- 0 V - 2 V
- Voltage input signal
- 0 V - 2.4 V
- Voltage input signal
- 0 V - 3 V
- Max. input voltage
- approx. 3 V DC
- Input resistance of voltage input
- approx. 10 kΩ
Note
- Utilization restriction
- EMC: class A product, see manufacturer's declaration in the download area
Dimensions
- Width
- 6.2 mm
- Height
- 93.1 mm
- Depth
- 102.5 mm
Connection data
- Connection method
- Spring-cage connection
- Conductor cross section solid min.
- 0.2 mm²
- Conductor cross section solid max.
- 2.5 mm²
- Conductor cross section AWG min.
- 24
- Conductor cross section AWG max.
- 12
- Conductor cross section flexible min.
- 0.2 mm²
- Conductor cross section flexible max.
- 2.5 mm²
- Stripping length
- 8 mm
- Connection technology
- 2-wire
Output data
- Number of outputs
- 1
- Configurable/programmable
- Yes, preconfigured
- Voltage output signal
- 0 V - 10 V
- Voltage output signal
- 2 V - 10 V
- Voltage output signal
- 0 V - 5 V
- Voltage output signal
- 1 V - 5 V
- Voltage output signal
- -10 V - 10 V (The bi-polar output can be used only for bi-polar input signals.)
- Voltage output signal
- -5 V - 5 V (The bi-polar output can be used only for bi-polar input signals.)
- Current output signal
- 0 mA - 20 mA
- Current output signal
- 4 mA - 20 mA
- Load/output load voltage output
- ≥ 10 kΩ
- Load/output load current output
- < 500 Ω (at 20 mA)
- Ripple
- < 20 mVPP (at 500 Ω)
- Ripple
- < 20 mVPP (at 10 kΩ)
Ambient conditions
- Ambient temperature (operation)
- -20 °C - 65 °C
- Ambient temperature (storage/transport)
- -40 °C - 85 °C
- Maximum altitude
- ≤ 2000 m
Environmental Product Compliance
- China RoHS
- Environmentally Friendly Use Period = 50
- China RoHS
- For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
EMC data
- Designation
- Electromagnetic RF field
- Standards/regulations
- EN 61000-4-3
- Typical deviation from the measuring range final value
- 6 %
- Designation
- Fast transients (burst)
- Standards/regulations
- EN 61000-4-4
- Typical deviation from the measuring range final value
- 6 %
- Designation
- Conducted interferences
- Standards/regulations
- EN 61000-4-6
- Typical deviation from the measuring range final value
- 6 %
Standards and Regulations
- Electromagnetic compatibility
- Conformance with EMC directive
- Noise emission
- EN 61000-6-4
- Connection in acc. with standard
- CUL
- Standards/regulations
- EN 61000-4-2
- Designation
- Electromagnetic RF field
- Standards/regulations
- EN 61000-4-3
- Standards/regulations
- EN 61000-4-4
- Standards/regulations
- EN 61000-4-5
- Designation
- Conducted interferences
- Standards/regulations
- EN 61000-4-6
- Electrical isolation
- Basic insulation according to EN 61010
- Conformance
- CE-compliant
- ATEX
- II 3 G Ex nA IIC T4 Gc X
- UL, USA/Canada
- UL 508 Recognized
- UL, USA/Canada
- Class I, Div. 2, Groups A, B, C, D T4
- Fire protection for rail vehicles (DIN EN 45545-2) R22
- HL 1 - HL 2
- Fire protection for rail vehicles (DIN EN 45545-2) R23
- HL 1 - HL 2
- Fire protection for rail vehicles (DIN EN 45545-2) R24
- HL 1 - HL 2
Power supply
- Nominal supply voltage
- 24 V DC
- Supply voltage range
- 19.2 V DC - 30 V DC
- Max. current consumption
- < 25 mA
- Power consumption
- < 450 mW (Current output)
Other Categories
ActuatorsBlocksCables, Pipes & HosesCompressorsControlCouplings & FittingsCylinders & PistonsElectronicsFiltersHVACIndustrial PC's & HMIsLightingLinear techniqueMotorsPower SupplyPower TransmissionPumps & ValvesRenewable energyRoboticsSeals, Rings & ConnectorsSensors & Measuring DevicesTools and AccessoriesCNCOther