Phoenix Contact
2811763
Temperature measuring transducer - MACX MCR-EX-T-UI-UP-C - 2811763
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Send request for price
1
Payment methods:
Input data
- Sensor types (RTD) that can be used
- Pt, Ni, Cu sensors: 2, 3, 4-wire
- Sensor types that can be used (TC)
- B, E, J, K, N, R, S, T, L, U, CA, DA, A1G, A2G, A3G, MG, LG
- Temperature measuring range
- -250 °C - 2500 °C (Range depending on the sensor type)
- Input signal range
- 0 Ω - 50 kΩ
- Potentiometer resistance range
- 0 Ω - 50 kΩ
- Input signal range
- -1000 mV - 1000 mV
Note
- Utilization restriction
- EMC: class A product, see manufacturer's declaration in the download area
Dimensions
- Width
- 17.5 mm
- Height
- 112.8 mm
- Depth
- 113.7 mm
Connection data
- Connection method
- Screw connection
- Stripping length
- 7 mm
- Screw thread
- M3
- Conductor cross section solid
- 0.2 mm² - 2.5 mm²
- Conductor cross section flexible
- 0.2 mm² - 2.5 mm²
- Conductor cross section AWG
- 24 - 14
- Torque
- 0.5 Nm - 0.6 Nm
Output data
- Max. voltage output signal
- ± 11 V
- Current output signal
- 4 mA - 20 mA (in the case of SIL; further free configuration without SIL)
- Max. current output signal
- 22 mA
- Load/output load voltage output
- ≥ 10 kΩ
- Load/output load current output
- ≤ 600 Ω (at 20 mA)
- Behavior in the event of a sensor error
- according to NE 43 or freely configurable
- Output name
- Switching output
- Contact type
- 1 PDT
- Contact material
- AgSnO₂, hard gold-plated
- Maximum switching voltage
- 30 V AC (30 V DC)
- Maximum inrush current
- 0.5 A (30 V AC)
- Maximum inrush current
- 1 A (30 V DC)
- Mechanical service life
- 1x 10⁵ cycles
Ambient conditions
- Ambient temperature (operation)
- -20 °C - 65 °C
- Ambient temperature (storage/transport)
- -40 °C - 85 °C
- Maximum altitude
- ≤ 2000 m
- Permissible humidity (operation)
- typ. 5 % - 95 % (non-condensing)
- Degree of protection
- IP20 (not assessed by UL)
- Noise immunity
- EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
- Shock
- 15g, according to IEC 60068-2-27
- Vibration (operation)
- 5g, accordance to IEC 60068-2-6
Environmental Product Compliance
- REACh SVHC
- Lead 7439-92-1
- China RoHS
- Environmentally Friendly Use Period = 50 years
- China RoHS
- For details about hazardous substances go to tab 'Downloads', Category 'Manufacturer's declaration'
EMC data
- Designation
- Electromagnetic RF field
- Standards/regulations
- EN 61000-4-3
- Typical deviation from the measuring range final value
- 2 %
- Designation
- Fast transients (burst)
- Standards/regulations
- EN 61000-4-4
- Designation
- Conducted interferences
- Standards/regulations
- EN 61000-4-6
Safety data
- Max. internal inductance Li
- negligible
- Max. internal capacitance Ci
- 44 nF
- Max. output voltage Uo
- 6 V
- Max. output current Io
- 7.4 mA
- Max. output power Po
- 11 mW
- Group
- IIC
- Max. external inductivity Lo
- 100 mH
- Max. external capacitance Co
- 1.3 µF
- Max. external inductivity Lo
- 10 mH
- Max. external capacitance Co
- 1.7 µF
- Max. external inductivity Lo
- 1 mH
- Max. external capacitance Co
- 2.6 µF
- Group
- IIB
- Max. external capacitance Co
- 6.8 µF
- Max. external capacitance Co
- 9.2 µF
- Max. external capacitance Co
- 15 µF
- Safety-related maximum voltage Um
- 253 V AC/DC
Standards and Regulations
- Electromagnetic compatibility
- Conformance with EMC directive
- Noise emission
- EN 61000-6-4
- Designation
- Electromagnetic RF field
- Standards/regulations
- EN 61000-4-3
- Standards/regulations
- EN 61000-4-4
- Designation
- Conducted interferences
- Standards/regulations
- EN 61000-4-6
- Electrical isolation
- 4-way, between input/output/power supply/switching output
- Shock
- 15g, according to IEC 60068-2-27
- Vibration (operation)
- 5g, accordance to IEC 60068-2-6
- Conformance
- CE-compliant
- ATEX
- II (1) G [Ex ia Ga] IIC
- ATEX
- II (1) D [Ex ia Da] IIIC
- ATEX
- II 3 G Ex nA nC ic IIC T4 Gc X
- IECEx
- [Ex ia Ga] IIC
- IECEx
- [Ex ia Da] IIIC
- IECEx
- Ex nA nC ic IIC T4 Gc X
- UL, USA/Canada
- UL 508 Listed
- DNV GL-Temperature
- B
- DNV GL-Humidity
- B
- DNV GL-Vibration
- A
- DNV GL-EMC
- A
- DNV GL-Enclosure
- Required protection according to the Rules shall be provided upon installation on board
- Group
- IIC
- Group
- IIB
Power supply
- Supply voltage range
- 24 V - 230 V AC/DC (-20 %/+10 %, 50/60 Hz)
- Typical current consumption
- < 50 mA (24 V DC)
- Power consumption
- < 1.5 W
Other Categories
NanometersManometersFlowmetersSensorsAcceleration SensorsFiber Optic SensorsDetectorsUltrasonic SensorsTemperature & Humidity SensorsVibration SensorsLevel SensorsPressure SensorsProximity SensorsInductive SensorsMotion SensorsMagnetic Sensors GroupOptical SensorsCapacitive SensorsPhotoelectric SensorsPosition SensorsEncodersOther sensors and Accessories