FO patch cable - FL MM PATCH 2,0 ST-ST - 2901816
2901816
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:

Mechanical properties

Bending radius short term/long term
30 mm
Bending radius, long-term
60 mm
Lateral pressure, long-term
60.00 N/cm
Tensile strength short-term/long-term
600 N
Cable, attenuation
2.5 dB/km
Cable, attenuation
0.7 dB/km
Numerical aperture
0.2

Attenuation

850 nm
2.5 dB/km
1300 nm
0.7 dB/km

Behavior in fire

Flame resistance
according to DIN 60332-1-2
Flame resistance
IEC 60332-3-22 (Cat. A)
Concentration of fumes
in accordance with IEC 61034
Halogen-free
According to IEC 60754-2
Behavior in fire
No corrosive or toxic fumes
Behavior in fire
0.36 MJ/m

Cable type

Cable abbreviation
I-V(ZN)H
Cable type
Multimode fiberglass
Cable weight
15.80 kg/km

Ambient conditions

Ambient temperature (operation)
-5 °C - 70 °C
Ambient temperature (storage/transport)
-25 °C - 70 °C
Ambient temperature (installation)
-5 °C - 50 °C
Resistance to oil
Not resistant to oil, gasoline, acids, and lyes

Environmental Product Compliance

REACh SVHC
Lead 7439-92-1
China RoHS
Environmentally Friendly Use Period = 50 years
China RoHS
For details about hazardous substances go to tab 'Downloads', Category 'Manufacturer's declaration'

External sheath

Outer sheath, material
FRNC
External sheath, color
orange
External sheath, strain relief elements
Non-metallic, aramide fiber
External diameter max.
5.7 mm
External diameter min.
2.8 mm

Single wire

Single wires, quantity
2
Individual wire, diameter
900 µm
Single wire, strain relief elements
Non-metallic, aramide fibers

Standards and Regulations

Concentration of fumes
in accordance with IEC 61034
Flame resistance
according to DIN 60332-1-2
Flame resistance
IEC 60332-3-22 (Cat. A)
Resistance to oil
Not resistant to oil, gasoline, acids, and lyes
Halogen-free
According to IEC 60754-2
Behavior in fire
No corrosive or toxic fumes
Behavior in fire
0.36 MJ/m