Input data

Configurable/programmable
Yes
Sensor types that can be used (TC)
B, C, E, J, K, N, R, S, T, L, U, A-1, A-2, A-3, M, L
Temperature measuring range
-250 °C - 2500 °C (Range depends on sensor type, range can be set freely via software or in increments from -150°C to 1350°C via DIP switches)

Note

Utilization restriction
EMC: class A product, see manufacturer's declaration in the download area

Dimensions

Width
6.2 mm
Height
109.81 mm
Depth
119.2 mm

Connection data

Connection method
Screw connection
Stripping length
10 mm
Screw thread
M3
Conductor cross section solid
0.2 mm² - 1.5 mm² (with ferrule)
Conductor cross section solid
0.14 mm² - 2.5 mm² (without ferrule)
Conductor cross section flexible
0.14 mm² - 2.5 mm²
Conductor cross section AWG
24 - 12 (flexible)
Torque
0.5 Nm - 0.6 Nm

Output data

Number of outputs
1
Configurable/programmable
Yes
Voltage output signal
0 V - 5 V (via DIP switch)
Voltage output signal
1 V - 5 V (via DIP switch)
Voltage output signal
0 V - 10 V (via DIP switch)
Voltage output signal
10 V - 0 V (via DIP switch)
Voltage output signal
0 V - 10.5 V (can be set via software)
Current output signal
0 mA - 20 mA (via DIP switch)
Current output signal
4 mA - 20 mA (via DIP switch)
Current output signal
20 mA - 0 mA (via DIP switch)
Current output signal
20 mA - 4 mA (via DIP switch)
Current output signal
0 mA - 21 mA (can be set via software)
Max. output voltage
approx. 12.3 V
Max. output current
24.6 mA
Short-circuit current
< 31.5 mA
Load/output load voltage output
≥ 10 kΩ
Load/output load current output
≤ 600 Ω (at 20 mA)
Ripple
< 10 mVrms
Ripple
< 10 mVrms (at 600 Ω)

Ambient conditions

Ambient temperature (operation)
-40 °C - 70 °C
Ambient temperature (storage/transport)
-40 °C - 85 °C
Permissible humidity (operation)
5 % - 95 % (non-condensing)
Degree of protection
IP20 (not assessed by UL)
Noise immunity
EN 61000-6-2 When being exposed to interference, there may be minimal deviations.

Environmental Product Compliance

REACh SVHC
Lead 7439-92-1
China RoHS
Environmentally Friendly Use Period = 50 years
China RoHS
For details about hazardous substances go to tab 'Downloads', Category 'Manufacturer's declaration'

EMC data

Designation
Electromagnetic RF field
Standards/regulations
EN 61000-4-3
Typical deviation from the measuring range final value
0.06 %
Designation
Fast transients (burst)
Standards/regulations
EN 61000-4-4
Typical deviation from the measuring range final value
0.1 %
Designation
Conducted interferences
Standards/regulations
EN 61000-4-6
Typical deviation from the measuring range final value
0.05 %

Standards and Regulations

Electromagnetic compatibility
Conformance with EMC directive
Noise emission
EN 61000-6-4
Standards/regulations
EN 61000-4-2
Designation
Electromagnetic RF field
Standards/regulations
EN 61000-4-3
Standards/regulations
EN 61000-4-4
Standards/regulations
EN 61000-4-5
Designation
Conducted interferences
Standards/regulations
EN 61000-4-6
Electrical isolation
Reinforced insulation in accordance with IEC 61010-1
Conformance
CE-compliant
ATEX
II 3 G Ex nA IIC T4 Gc X
UL, USA/Canada
UL 508 Listed
UL, USA/Canada
Class I, Div. 2, Groups A, B, C, D T6
UL, USA/Canada
Class I, Zone 2, Group IIC T6

Power supply

Supply voltage range
9.6 V DC - 30 V DC (The DIN rail bus connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, Order No. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715))
Typical current consumption
32.7 mA (24 V DC)
Typical current consumption
66.8 mA (12 V DC)
Power consumption
≤ 850 mW (at IOUT = 20 mA, 9.6 V DC, 600 Ω load)