Safety relays - PSR-SCP- 24DC/MXF1/4X1/2X2/B - 2902725
2902725
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Offer with manufacturer lead time
Ships in:On Request
Best price:
€257.00

Additional Information

Part Number
2902725
UPC
4046356673006
Country of Origin
DE
ETIM
Group Code : EG000019
Group Description : Relays
Class Description : Device for monitoring of safety-related circuits
Class Code : EC001449
Version : 7

Input data

Nominal input voltage UN
24 V DC
Input voltage range in reference to UN
0.85 - 1.1
Typical input current at UN
125 mA (with actuated relays)
Typical input current at UN
55 mA (Two-channel 24 V/0 V + max. 200 mA control (message outputs 32/62) with non-actuated relays)
Current consumption
typ. 5 mA (Imax/Ix inputs)
Current consumption
20 mA (in electric torque)
Voltage at input/start and feedback circuit
24 V -15 %; +10 % (first channel: 24 V; second channel: 0 V)
Typical response time
175 ms (monitored/manual start)
Typical response time
250 ms (automatic start)
Typ. starting time with Us
250 ms (when controlled via A1)
Typical release time
25 ms (when controlled via S11/I1,I3,I5 and S21/I2,I4,I6)
Typical release time
20 ms (when controlled via A1)
Concurrence input 1/2
Recovery time
1 s (Availability time after activation of sensor circuit: 100ms)
Operating voltage display
1 x green LED
Status display
5x LED green
Protective circuit
Surge protection Suppressor diode
Maximum switching frequency
0.5 Hz
Max. permissible overall conductor resistance
100 Ω
Filter time
max. 1.5 ms (Test pulse duration; for all equivalent inputs)
Filter time
min. 7.5 ms (Test pulse rate; for all equivalent inputs)

Note

Utilization restriction
EMC: class A product, see manufacturer's declaration in the download area

Dimensions

Width
22.5 mm
Height
112.2 mm
Depth
114.5 mm

Connection data

Connection method
Screw connection
Pluggable
Yes
Conductor cross section solid min.
0.2 mm²
Conductor cross section solid max.
2.5 mm²
Conductor cross section flexible min.
0.2 mm²
Conductor cross section flexible max.
2.5 mm²
Conductor cross section AWG min.
24
Conductor cross section AWG max.
12
Stripping length
7 mm
Screw thread
M3

Output data

Contact type
4 enabling current paths
Contact type
2 semiconductor alarm outputs
Contact material
AgCuNi, +0.2 -0.4 µm Au
Maximum switching voltage
250 V AC/DC
Minimum switching voltage
10 V AC/DC
Limiting continuous current
6 A (N/O contact)
Limiting continuous current
max. 100 mA (Alarm output (24 V DC))
Maximum inrush current
6 A
Inrush current, minimum
10 mA
Sq. Total current
72 A² (ITH² = I₁² + I₂²+ I₃²+ I₄²)
Interrupting rating (ohmic load) max.
1500 VA (250 V AC, τ = 0 ms)
Interrupting rating (ohmic load) max.
66 W (220 V DC, τ = 0 ms)
Interrupting rating (ohmic load) max.
66 W (110 V DC, τ = 0 ms)
Interrupting rating (ohmic load) max.
100 W (48 V DC, τ = 0 ms)
Interrupting rating (ohmic load) max.
144 W (24 V DC, τ = 0 ms)
Maximum interrupting rating (inductive load)
48 W (24 V DC, τ = 40 ms)
Maximum interrupting rating (inductive load)
43 W (48 V DC, τ = 40 ms)
Switching capacity min.
0.1 W
Mechanical service life
10x 10⁶ cycles
Switching capacity (360/h cycles)
5 A (0,1 Hz; DC13; 24 V)
Output fuse
6 A gL/gG NEOZED (N/O contact)
Output fuse
4 A gL/gG NEOZED (for low-demand applications)

Ambient conditions

Ambient temperature (operation)
-20 °C - 45 °C (see derating curve)
Ambient temperature (storage/transport)
-25 °C - 85 °C
Max. permissible relative humidity (operation)
75 % (on average, 85% infrequently, non-condensing)
Max. permissible humidity (storage/transport)
75 % (on average, 85% infrequently, non-condensing)
Maximum altitude
≤ 2000 m (Above sea level)

Environmental Product Compliance

REACh SVHC
Lead 7439-92-1
China RoHS
Environmentally Friendly Use Period = 50 years
China RoHS
For details about hazardous substances go to tab 'Downloads', Category 'Manufacturer's declaration'

Standards and Regulations

Designation
Air clearances and creepage distances between the power circuits
Standards/regulations
DIN EN 50178/VDE 0160
Rated insulation voltage
250 V AC
Rated surge voltage/insulation
4 kV/basic isolation (safe isolation, reinforced insulation and 6 kV between input circuit, enabling current paths and safety circuit 1 (13/14, 23/24) and safety circuit 2 (43/44, 53/54).)
Degree of pollution
2
Overvoltage category
III

Safety-related characteristic data

Stop category
0
Safety Integrity Level (SIL)
3
Designation
EN ISO 13849
Performance level (PL)
e (5 A DC13; 3 A AC15; 8760 cycles/year)
Category
4
Safety Integrity Level Claim Limit (SIL CL)
3
Designation
EN 50156

CAD Models

Trace parts
Trace parts
Download