Phoenix Contact
2904334
Hybrid motor starter - ELR-H51-0,6-BUSBAR-CLASSIC-SET - 2904334
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Send request for price
1
Payment methods:
Product Conditions:
Offer with manufacturer lead time
Ships in:On Request
Best price:
Send request for price
Additional Information
- Part Number
- 2904334
- UPC
- 4046356802406
- ETIM
- Group Code : EG000017
- Group Description : Low-voltage Industrial Components
- Class Description : Motor starter/Motor starter combination
- Class Code : EC001037
- Version : 7
Input data
- Input name
- Control input right/left
- Rated actuating voltage UC
- 24 V DC
- Triggering voltage range
- 19.2 V DC - 30 V DC
- Rated actuating current IC
- 5 mA
- Switching threshold
- 9.6 V ('0' signal)
- Switching threshold
- 19.2 V ('1' signal)
- Switching level
- < 5 V DC (For EMERGENCY STOP)
- Typical turn-off time
- < 30 ms
Connection data 2
- Connection name
- Load circuit
- Connection method
- Screw connection
- Stripping length
- 8 mm
- Screw thread
- M3
- Conductor cross section solid
- 0.2 mm² - 2.5 mm²
- Conductor cross section flexible
- 0.2 mm² - 2.5 mm²
- Conductor cross section AWG
- 24 - 14
- Torque
- 0.5 Nm - 0.6 Nm
- Torque
- 5 lbf-in. - 7 lbf-in.
Connection data
- Connection name
- Control circuits
- Connection method
- Screw connection
- Stripping length
- 8 mm
- Screw thread
- M3
- Conductor cross section solid
- 0.2 mm² - 2.5 mm²
- Conductor cross section flexible
- 0.2 mm² - 2.5 mm²
- Conductor cross section AWG
- 24 - 14
- Torque
- 0.5 Nm - 0.6 Nm
- Torque
- 5 lbf-in. - 7 lbf-in.
Insulation characteristics
- Rated insulation voltage
- 500 V
- Rated surge voltage
- 6 kV
- Overvoltage category
- III
- Degree of pollution
- 2
- Designation
- Insulation characteristics between the control input and control supply voltage, and auxiliary circuit to the main circuit
- Insulation
- Safe isolation (IEC 60947-1) at operating voltage ≤ 300 V AC
- Insulation
- Safe isolation (EN 50178) at operating voltage ≤ 300 V AC
- Insulation
- Basic isolation (IEC 60947-1) at operating voltage 300 - 500 V AC
- Insulation
- Safe isolation (EN 50178) at operating voltage 300 - 500 V AC
- Designation
- Isolation characteristics between the control input and control supply voltage to auxiliary circuit
- Insulation
- Safe isolation (IEC 60947-1) in the auxiliary circuit ≤ 300 V AC
- Insulation
- Safe isolation (EN 50178) in the auxiliary circuit ≤ 300 V AC
Device supply
- Rated control circuit supply voltage US
- 24 V DC
- Control supply voltage range
- 19.2 V DC - 30 V DC
- Rated control supply current IS
- 40 mA
- Type of protection
- Surge protection
- Type of protection
- Reverse polarity protection
Output data reply output
- Output name
- Acknowledge output
- Note
- Confirmation: floating change-over contact, signal contact
- Contact type
- 1 PDT
- Switching capacity according to IEC 60947-5-1
- 3 A (230 V, AC15)
- Switching capacity according to IEC 60947-5-1
- 2 A (24 V, DC13)
Ambient conditions
- Ambient temperature (operation)
- -25 °C - 70 °C (observe derating)
- Ambient temperature (storage/transport)
- -40 °C - 80 °C
- Maximum altitude
- ≤ 2000 m
- Degree of protection
- IP20
UL data
- SCCR
- 100 kA (480 V AC (fuse: 30 A class CC/30 A class J (high fault)))
- SCCR
- 5 kA (480 V AC (fuse: 20 A RK5 (standard fault)))
- FLA
- 0.6 A (480 V AC)
- Group installation
- 20 A (class RK5, SCCR 5kA, #24 - 14 AWG max. solid and stranded)
- Group installation
- 30 A (class CC or J, SCCR 100kA, #24 - 14 AWG max, solid and stranded)
- Category code
- NLDX / NRNT
Conformance/approvals
- Designation
- ATEX
- Identification
- II (2) G [Ex e] [Ex d] [Ex px]
- Identification
- II (2) D [Ex t] [Ex p]
- Certificate
- PTB 07 ATEX 3145
- Designation
- UL approval
- Certificate
- NLDX.E228652
- Designation
- Safety Integrity Level (SIL, IEC 61508)
- Identification
- ≤ 3
- Additional text
- Safe shutdown
- Identification
- 2
- Additional text
- Motor protection
- Designation
- Performance Level (ISO 13849)
- Identification
- e
- Designation
- Category (ISO 13849)
- Identification
- 3
Output data load output
- Output name
- AC output
- Rated operating voltage Ue
- 500 V AC
- Operating voltage range
- 42 V AC - 550 V AC
- Mains frequency
- 50/60 Hz
- Load current range
- 75 mA - 600 mA
- Trigger characteristic in acc. with IEC 60947-4-2
- Class 10A
- Cooling time
- 20 min. (for auto reset)
- Leakage current
- 0 mA
- Type of protection
- Surge protection
- Type of protection
- Short-circuit protection
Environmental Product Compliance
- REACh SVHC
- Lead 7439-92-1
- China RoHS
- Environmentally Friendly Use Period = 50 years
- China RoHS
- For details about hazardous substances go to tab 'Downloads', Category 'Manufacturer's declaration'
Standards and Regulations
- Designation
- Standards/regulations
- Standards/regulations
- IEC 60947-1
- Standards/regulations
- EN 60947-4-2
- Standards/regulations
- IEC 61508
- Standards/regulations
- ISO 13849