Phoenix Contact
2905000
Front adapters - FLK 50-PA/EZ-DR/HF/KS/4000/YOC - 2905000
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Send request for price
1
Payment methods:
Offer with manufacturer lead time
Ships in:On Request
Best price:
Send request for price
Additional Information
- Part Number
- 2905000
- UPC
- 4046356906982
- ETIM
- Group Code : EG000024
- Group Description : PLC's
- Class Description : Accessories for controls
- Class Code : EC002584
- Version : 7
Supported controller
- Controller
- Yokogawa ProSafe-RS
Note
- Type of note
- Notes on operation
- Note
- No additional touch protection is required when using a SELV/PELV voltage (≤ 25 V AC or 60 V DC).
Connection data 2
- Connection name
- Field level
- Connection method
- Yokogawa, KS compatible
- Number of connections
- 1
- Number of positions
- 50
- Torque
- 0.5 Nm (Screw connection)
- Insertion/withdrawal cycles
- > 50
Connection data
- Connection name
- Controller level
- Connection method
- Yokogawa, I/O cards compatible
- Number of connections
- 1
- Number of positions
- 50
- Torque
- 0.5 Nm (Screw connection)
- Insertion/withdrawal cycles
- > 50
Ambient conditions
- Ambient temperature (operation)
- -40 °C - 70 °C (fixed installation)
- Ambient temperature (operation)
- -10 °C - 70 °C (flexible installation)
- Ambient temperature (storage/transport)
- -40 °C - 80 °C
- Maximum altitude
- ≤ 2000 m
- Degree of protection
- IP20
- Degree of protection
- ≥ IP54 (Installation location)
Environmental Product Compliance
- REACh SVHC
- Lead 7439-92-1
- China RoHS
- Environmentally Friendly Use Period = 50 years
- China RoHS
- For details about hazardous substances go to tab 'Downloads', Category 'Manufacturer's declaration'
Standards and Regulations
- Flame resistance
- IEC 60332-3-22
- Flame resistance
- IEC 60332-1-2
- Flame resistance
- VDE 0842, Part 332-1-2
- Resistance to oil
- against occasional splashes
- Gasoline resistance
- against occasional splashes
- Designation
- Air clearances and creepage distances
- Standards/regulations
- DIN EN 50178
- Rated insulation voltage
- 63 V
- Rated surge voltage
- 0.6 kV
- Insulation
- Functional insulation
- Pollution degree
- 2
- Overvoltage category
- II
Cable
- Conductor construction: Number of litz wires:
- 7
- Single wire, material
- Cu tin-plated
- Single wire, cross section
- 0.14 mm²
- Shielding
- Tinned copper-braided shield, approx. 85% covering
- Length of cable
- 40 m
- Outer sheath, material
- Halogen-free sheath
- External sheath, color
- gray
- Shielding
- yes
- Halogen-free cable
- Yes
- Cable insulation resistance
- ≥ 20 MΩ/km
- Cable resistance
- ≤ 145 Ω/km