Phoenix Contact
2981415
Coupling relay 2981415
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
346,03 zł
1
Payment methods:
Product Conditions:
Input data
- Rated control circuit supply voltage U<sub>S</sub>
- 120 V AC/DC -20 % - +10 %
- Rated control supply current I<sub>S</sub>
- typ. 11 mA
- Power consumption at U<sub>S</sub>
- typ. 1.32 W
- Inrush current
- typ. 600 mA (Δt = 200 µs at Us)
- Typ. starting time with U<sub>s</sub>
- typ. 20 ms (when controlled via A1)
- Typical release time
- typ. 20 ms (when controlled via A1)
- Recovery time
- < 500 ms
- Operating voltage display
- 1 x green LED
- Protective circuit
- Surge protection Varistor
- Maximum switching frequency
- 0.5 Hz
Dimensions
- Width
- 22.5 mm
- Height
- 114.5 mm
- Depth
- 112 mm
Connection data
- Connection method
- Spring-cage connection
- Pluggable
- Yes
- Conductor cross section solid min.
- 0.2 mm²
- Conductor cross section solid max.
- 1.5 mm²
- Conductor cross section flexible min.
- 0.2 mm²
- Conductor cross section flexible max.
- 1.5 mm²
- Conductor cross section AWG min.
- 24
- Conductor cross section AWG max.
- 16
- Stripping length
- 8 mm
Output data
- Contact type
- 5 enabling current paths
- Contact type
- 2 confirmation current paths
- Contact material
- AgSnO2
- Maximum switching voltage
- 230 V AC/DC (Observe the load curve)
- Minimum switching voltage
- 5 V AC/DC
- Limiting continuous current
- 6 A (N/O contact)
- Limiting continuous current
- 3 A (N/C contact)
- Maximum inrush current
- 6 A
- Inrush current, minimum
- 10 mA
- Sq. Total current
- 72 A2
- Interrupting rating (ohmic load) max.
- 144 W (N/O contact, 24 V DC, τ = 0 ms)
- Interrupting rating (ohmic load) max.
- 288 W (N/O contact, 48 V DC, τ = 0 ms)
- Interrupting rating (ohmic load) max.
- 240 W (N/O contact, 60 V DC, τ = 0 ms)
- Interrupting rating (ohmic load) max.
- 110 W (N/O contact, 110 V DC, τ = 0 ms)
- Interrupting rating (ohmic load) max.
- 88 W (N/O contact, 220 V DC, τ = 0 ms)
- Interrupting rating (ohmic load) max.
- 1380 VA (N/O contact, 230 V AC, τ = 0 ms)
- Maximum interrupting rating (inductive load)
- 42 W (N/O contact, 24 V DC, τ = 40 ms)
- Maximum interrupting rating (inductive load)
- 42 W (N/O contact, 48 V DC, τ = 40 ms)
- Maximum interrupting rating (inductive load)
- 42 W (N/O contact, 60 V DC, τ = 40 ms)
- Maximum interrupting rating (inductive load)
- 42 W (N/O contact, 110 V DC, τ = 40 ms)
- Maximum interrupting rating (inductive load)
- 42 W (N/O contact, 220 V DC, τ = 40 ms)
- Switching capacity
- min. 50 mW
- Mechanical service life
- 10x 106 cycles
- Switching capacity (360/h cycles)
- 4 A (24 V (DC13))
- Switching capacity (360/h cycles)
- 4 A (250 V (AC15))
- Switching capacity according to IEC 60947-5-1
- 3 A (24 V (DC13))
- Switching capacity according to IEC 60947-5-1
- 3 A (250 V (AC15))
- Output fuse
- 10 A gL/gG (N/O contact)
- Output fuse
- 4 A gL/gG (N/O contact, for low-demand applications)
- Output fuse
- 6 A gL/gG (N/C contact)
Ambient conditions
- Ambient temperature (operation)
- -20 °C - 55 °C
- Ambient temperature (storage/transport)
- -40 °C - 85 °C
- Max. permissible relative humidity (operation)
- 75 % (on average, 85% infrequently, non-condensing)
- Max. permissible humidity (storage/transport)
- 75 % (on average, 85% infrequently, non-condensing)
- Maximum altitude
- ≤ 2000 m (Above sea level)
Environmental Product Compliance
- China RoHS
- Environmentally friendly use period: unlimited = EFUP-e
- China RoHS
- No hazardous substances above threshold values
Standards and Regulations
- Designation
- Air clearances and creepage distances between the power circuits
- Standards/regulations
- DIN EN 50178
- Rated insulation voltage
- 250 V
- Rated insulation voltage
- 250 V
- Rated surge voltage/insulation
- 4 kV basic insulation (4 kV safe isolation, reinforced insulation between A1/A2, 13/14, 23/24, 33/34 to 43/44, 53/54, 61/62, 71/72)
- Degree of pollution
- 2
- Overvoltage category
- III
- Shock
- 15g (In the event of stress caused by shock, contact reactions are possible for up to 2 ms.)
- Vibration (operation)
- 10 Hz ...150 Hz, 2g (In the event of stress caused by vibration, contact reactions are possible for up to 1 ms.)
- Conformance
- CE-compliant
Safety-related characteristic data
- Stop category
- 0
- Designation
- IEC 61508 - High demand
- Safety Integrity Level (SIL)
- 1
- Designation
- IEC 61508 - Low demand
- Safety Integrity Level (SIL)
- 1
- Designation
- EN ISO 13849
- Performance level (PL)
- c
- Category
- 1
- Safety Integrity Level Claim Limit (SIL CL)
- 1