Fluke Networks
OFP-200-S1625-MOD
OptiFiber® Pro OTDR Family
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Send request for price
1
Payment methods:
Additional Information
- Part Number
- OFP-200-S1625-MOD
Additional key specifications
- Magnification
- ~ 200X with OptiFiber Pro Display
- Light source
- Blue LED
- Power source
- Versiv mainframe
- Field of View (FOV)
- Horizontal: 425 µm || Vertical: 320 µm
- Minimum detectable particle size
- 0. 5 µm
- Dimensions
- Mainframe with module and battery: 2. 625 in x 5. 25 in x 11. 0 in ( 6. 67 cm x 13. 33 cm x 27. 94 cm)
- Weight
- Mainframe with module and battery: 3 lbs, 5 oz (1. 28 kg)
- Temperature range
- Operating: 32°F to 122°F (0 °C to +50 °C) || Storage: -4°F to +158°F (-20°C to +70°C)
- Certifications
- CE (when used with the mainframe)
- On/Off control
- Mechanical switch and a button on the touch screen
- Output power
- 316 µW (-5 dBm) = peak power = 1. 0 mW (0 dBm)
- Operating wavelength
- 650 nm nominal
- Spectral width (RMS)
- ±3 nm
- Output modes
- Continuous wave Pulsed mode (2 Hz to 3 Hz blink frequency)
- Connector adapter
- 2. 5 mm universal
- Laser safety (classification)
- Class II CDRH Complies to EN 60825-2
- Battery
- Lithium ion battery pack, 7. 2 volts
- Battery life
- Eight hour Auto OTDR operation, dual wavelength, no video probe connected, 150 m of fiber
- Integrated Wi-Fi
- Meets IEEE 802. 11 a/b/g/n; dual band (2. 4 GHz and 5 GHz)
- Tester Off
- Four hours to charge from 10% to 90% capacity
- Tester On
- Six hours to charge from 10% to 90% capacity with the tester on
- Operating temperature*
- -10ºC to 45ºC
- Storage Temperature
- -10ºC to +60ºC
- Operating altitude
- 4,000 m (13123 ft) || 3200 m (10,500 ft) with ac adapter
- Storage altitude
- 12,000 m
- EMC
- EN 61326-1
Key OptiFiber Pro HDR Specification
- Wavelengths
- 1490 nm +/- 20 nm || 1550 nm +/- 20 nm || 1310 nm +/- 25 nm || 1625 nm +/- 20 nm
- Compatible fiber types
- Singlemode
- OTDR Port Connector
- Cleanable APC ferrule with removable SC adapter
- Event dead zone 1
- 0. 7 m (typical)
- Attenuation dead zone2
- 4m (typical)
- PON dead zone3
- 30 m (typical)
- Max distance range setting
- 260 km
- Dynamic range 4, 5
- 1310 nm: 42 dB (typical || 1490 nm: 41 dB (typical) || 1625 nm: 40 dB (typical) || 1550 nm: 41 dB (typical) || 1310 nm: 42 dB (typical)
- Reflectance range4
- -14 to -70 dB (typical)
- Sampling resolution
- 3 cm to 2 m
- Sampling points
- Up to 129000
- Pulse widths (nominal)
- 5, 10, 30, 50, 100, 300, 500, 1000, 3000, 5000, 10000, 20000 ns
- Distance uncertainty
- +/-(1 + 0. 0005*distance + 0. 5*resolution)
- Linearity
- ± 0. 03 dB/dB
- Reflectance uncertainty
- ±2 dB
- Test Time (per wavelength)
- Best resolution setting: 5 to 180 seconds/wavelength || Auto PON setting: 10 seconds/wavelength (typical) || Quick test setting: 3 seconds/wavelength (typical) || Manual PON setting: 3, 5, 10, 20, 40, 60, 90, 120, 180 seconds/wavelength || Manual setting: 3, 5, 10, 20, 40, 60, 90, 120, 180 seconds/wavelength || Auto setting: 5 seconds/wavelength (typical)
- Laser Classification
- Class 1 CDRH Complies to EN 60825-2, 3rd Edition
- Calibration Period
- 1 year
Key OptiFiber Pro OTDR specifications
- Wavelengths
- 850 nm +/- 10 nm || 1300 nm +35/-15 nm || 1550 nm +/- 30 nm || 1310 nm +/- 25 nm
- Compatible fiber types
- 50/125 µm || 62. 5/125 µm || Singlemode
- Event dead zone 1
- 1550 nm: 0. 6 m typical || 1310 nm: 0. 6 m typical || 850 nm: 0. 5 m typical || 1300 nm: 0. 7 m typical
- Attenuation dead zone 2
- 1310 nm: 3. 6 m typical || 1300 nm: 4. 5 m typical || 850 nm: 2. 5 m typical || 1550 nm: 3. 7 m typical
- Dynamic range 3, 5, 6
- 1300 nm: 30 dB typical || 850 nm: 28 dB typical || 1550 nm: 30 dB typical || 1310 nm: 32 dB typical
- Max distance range setting
- 40 km || MM: 40 km || SM: 130 km || 130 km
- Distance measurement range 4, 5, 7, 8, 9, 10
- 1310 nm: 80 km || 850 nm: 9 km || 1550 nm: 130 km || 1300 nm: 35 km
- Reflectance range 4, 5
- 1300 nm: -14 dB to -62 dB (typical) || 1310 nm: -14 dB to -65 dB (typical) || 1310 nm: -14 dB to -65dB (typical) || 1550 nm: -14 dB to -65 dB (typical) || 850 nm: -14 dB to -57 dB (typical)
- Sample resolution
- 3 cm to 400 cm
- Pulse widths (nominal)
- 1300 nm: 3, 5, 20, 40, 200, 1000 ns || 1310/1550 nm: 3, 10, 30, 100, 300, 1000, 3000, 10000, 20000 ns || 850 nm: 3, 5, 20, 40, 200 ns
- Test time (per wavelength)
- || Best resolution setting: 5 to 180 sec || Manual setting: 3, 5, 10, 20, 40, 60, 90, 120, 180 sec || Auto setting: 10 sec (typical) || Quick test setting: 2 sec (typical) || MM - 2 sec (typical), MM - 180 sec (max) || Manual setting: || -3, 5, 10, 20, 40, 60, 90, 120, 180 sec SM - 3, 5, 10, 20, 40, 60, 90, 120, 180 sec || DataCenter OTDR setting: 1 sec (typical at 850 nm), 7 sec (max) || DataCenter OTDR setting: || SM - 10 sec (typical), SM - 180 sec (max) || Auto setting: 5 sec (typical) || FaultMap setting: 10 sec (typical), 180 sec (max) || FaultMap setting: || Best resolution setting: 2 to 180 sec || MM – 1 sec (typical at 850 nm) MM – 7 sec (max) || MM – 2 sec (typical) || Quick test setting: || DataCenter OTDR setting: 20 sec (typical), 40 sec (max) || MM – 2 to 180 sec M || SM – 10 sec (typical) || SM – 5 sec (typical) || FaultMap setting: 2 sec (typical), 180 sec (max) || Quick test setting: 5 sec (typical) || MM – 5 sec (typical) || SM – 5 to 180 sec || Best resolution setting: || SM – 20 sec (typical) SM – 40 sec (max) || Auto setting:
Other Categories
ActuatorsBlocksCables, Pipes & HosesCompressorsControlCouplings & FittingsCylinders & PistonsElectronicsFiltersHVACIndustrial PC's & HMIsLightingLinear techniqueMotorsPower SupplyPower TransmissionPumps & ValvesRenewable energyRoboticsSeals, Rings & ConnectorsSensors & Measuring DevicesTools and AccessoriesCNCOther