Phoenix Contact
1405881
Sensor/actuator cable - SAC-5P-MR-FR SH SCO BK/.../... - 1405881...
- Part Number
- 1405881
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Send request for price
1
Payment methods:
Additional Information
- Part Number
- 1405881
- ETIM
- Group Code : EG000026
- Group Description : Sensors
- Class Description : Sensor-actuator patch cord
- Class Code : EC001855
- Version : 7
PVC yellow 105 °C [542]
- Cable type
- PVC yellow 105 °C
- Cable type (abbreviation)
- 542
- UL AWM style
- 2517 (105 °C / 300 V)
- AWG signal line
- 22
- Conductor structure signal line
- 30x 1.30 mm
- Core diameter including insulation
- 1.27 mm ±0.03 mm
- Wire colors
- Brown, blue, black, white, gray
- Overall twist
- 5 wires around filler to the core
- Shielding
- Tinned copper braided shield
- Optical shield covering
- 85 %
- External sheath, color
- yellow
- External cable diameter D
- 5.9 mm ±0.2 mm
- Minimum bending radius, flexible installation
- 12 x D
- Cable weight
- 57 kg/km
- Outer sheath, material
- PVC
- Material, filler
- PP
- Material conductor insulation
- PVC
- Conductor material
- Tin-plated Cu litz wires
- Insulation resistance
- ≥ (550 M Ohms/m @ 500V)
- Conductor resistance
- max. 50.5 Ω/km (20 °C)
- Nominal voltage, cable
- 300 V
- Special properties
- UL standards PLTC and ITC
- Flame resistance
- FT4
- Other resistance
- UV resistant
- Ambient temperature (operation)
- -30 °C - 105 °C (cable, fixed installation)
- Ambient temperature (operation)
- -5 °C - 105 °C (cable, flexible installation)
PUR halogen-free yellow [240]
- Cable type
- PUR halogen-free yellow
- Cable type (abbreviation)
- 240
- Cable abbreviation
- Li9YV1-C-V1-11Y
- UL AWM style
- 20549
- Conductor cross section
- 5x 0.34 mm²
- AWG signal line
- 22
- Conductor structure signal line
- 42x 0.10 mm
- Core diameter including insulation
- 1.27 mm ±0.02 mm
- Thickness, insulation
- ≥ 0.21 mm
- Wire colors
- Brown, white, blue, black, gray
- Overall twist
- 5 wires around filler to the core
- Length of twist, overall twist
- 55 mm
- Shielding
- Braided copper wires
- Optical shield covering
- 85 %
- External sheath, color
- yellow
- Outer sheath thickness
- approx. 0.8 mm
- External cable diameter D
- 5.9 mm ±0.2 mm
- Minimum bending radius, fixed installation
- 5 x D
- Minimum bending radius, flexible installation
- 10 x D
- Number of bending cycles
- 2000000
- Minimum bending radius, drag chain applications
- 10 x D
- Traversing path
- 10 m
- Traversing rate
- 3 m/s
- Acceleration
- 10 m/s²
- Cable weight
- 49 kg/km
- Outer sheath, material
- PUR
- Material conductor insulation
- PP
- Conductor material
- Bare Cu litz wires
- Insulation resistance
- ≥ 1 GΩ*km (at 20 °C)
- Conductor resistance
- 58 Ω/km (at 20 °C)
- Nominal voltage, cable
- ≤ 300 V AC
- Test voltage, cable
- ≥ 3000 V AC (Spark test)
- Test voltage Core/Shield
- ≥ 2000 V AC (for 60 s)
- Flame resistance
- in accordance with UL 758/1581 FT2
- Halogen-free
- in accordance with DIN VDE 0472 part 815
- Halogen-free
- According to EN 50267-2-1
- Resistance to oil
- According to DIN EN 60811-2-1, 168 h at 100°C
- Resistance to oil
- According to UL 758, 168 h at 60°C
- Other resistance
- hydrolysis and microbe resistant
- Other resistance
- Resistant to salt water
- Other resistance
- abrasion-resistant
- Other resistance
- Low adhesion
- Ambient temperature (operation)
- -40 °C - 80 °C (cable, fixed installation)
- Ambient temperature (operation)
- -25 °C - 80 °C (cable, flexible installation)
Dimensions
- Length of cable
- Free input (0.2 - 40.0 m)
Black PVC 105°C [535]
- Cable type
- Black PVC 105°C
- Cable type (abbreviation)
- 535
- UL AWM style
- 2517 (105 °C / 300 V)
- AWG signal line
- 22
- Conductor structure signal line
- 30x 1.30 mm
- Core diameter including insulation
- 1.27 mm ±0.03 mm
- Wire colors
- Brown, blue, black, white, gray
- Overall twist
- 5 wires around filler to the core
- Shielding
- Tinned copper braided shield
- Optical shield covering
- 85 %
- External sheath, color
- black
- External cable diameter D
- 5.9 mm ±0.2 mm
- Minimum bending radius, flexible installation
- 12 x D
- Cable weight
- 57 kg/km
- Outer sheath, material
- PVC
- Material, filler
- PP
- Material conductor insulation
- PVC
- Conductor material
- Tin-plated Cu litz wires
- Nominal voltage, cable
- 300 V
- Special properties
- UL standards PLTC and ITC
- Flame resistance
- FT4
- Other resistance
- UV resistant
- Ambient temperature (operation)
- -30 °C - 105 °C (cable, fixed installation)
Material
- Flammability rating according to UL 94
- HB
- Contact material
- CuSn
- Contact surface material
- Ni/Au
- Contact carrier material
- TPU GF
- Material of grip body
- TPU, hardly inflammable, self-extinguishing
- Material, knurls
- Zinc die-cast, nickel-plated
PUR halogen-free black [PUR]
- Cable type
- PUR halogen-free black
- Cable type (abbreviation)
- PUR
- Cable abbreviation
- LiF9YC11Y
- UL AWM style
- 20549 / 10493 (80°C/300 V)
- Conductor cross section
- 5x 0.34 mm² (Signal line)
- AWG signal line
- 22
- Conductor structure signal line
- 42x 0.10 mm
- Core diameter including insulation
- 1.27 mm ±0.02 mm (Signal line)
- Thickness, insulation
- ≥ 0.21 mm
- Wire colors
- Brown, white, blue, black, gray
- Overall twist
- 5 wires around filler to the core
- Shielding
- Tinned copper braided shield
- Optical shield covering
- 80 %
- External sheath, color
- black-gray RAL 7021
- Outer sheath thickness
- approx. 0.5 mm
- External cable diameter D
- 5.25 mm ±0.2 mm
- Smallest bending radius, fixed installation
- 26 mm
- Smallest bending radius, movable installation
- 52 mm (up to +60°C)
- Number of bending cycles
- 10000000
- Bending radius
- 52 mm
- Traversing path
- 10 m
- Traversing rate
- 3 m/s
- Acceleration
- 10 m/s²
- Cable weight
- 43 kg/km
- Outer sheath, material
- PUR
- Material conductor insulation
- PP
- Conductor material
- Bare Cu litz wires
- Insulation resistance
- 70 GΩ*km (at 20 °C)
- Conductor resistance
- max. 57 Ω/km (at 20 °C)
- Nominal voltage, cable
- 300 V (at 20 °C)
- Test voltage Core/Core
- 3000 V (at 20 °C)
- Special properties
- Flexible cable conduit capable
- Special properties
- Silicone-free
- Special properties
- Free of substances which would hinder coating with paint or varnish
- Special properties
- Low adhesion surface
- Flame resistance
- in accordance with UL 758/1581 FT2
- Flame resistance
- DIN EN 60332-2-2 (20 s)
- Halogen-free
- in accordance with DIN VDE 0472 part 815
- Halogen-free
- in accordance with DIN EN 50267-2-1
- Resistance to oil
- in accordance with DIN EN 60811-2-1
- Other resistance
- Highly resistant to acids, alkaline solutions and solvents
- Other resistance
- hydrolysis and microbe resistant
- Other resistance
- Resistant to salt water
- Other resistance
- partly UV-resistant in accordance with DIN EN ISO 4892-2-A
- Other resistance
- abrasion-resistant
- Ambient temperature (operation)
- -40 °C - 80 °C (cable, fixed installation)
- Ambient temperature (operation)
- -25 °C - 80 °C (cable, flexible installation)
Ambient conditions
- Ambient temperature (operation)
- -25 °C - 90 °C (Plug / socket)
- Degree of protection
- IP65
- Degree of protection
- IP67
Line characteristics
- Note
- This item is a sensor/actuator cable with a freely selectable cable type. The technical data for all possible cable types is listed in the table below.
Environmental Product Compliance
- China RoHS
- Environmentally Friendly Use Period = 50 years
- China RoHS
- For details about hazardous substances go to tab 'Downloads', Category 'Manufacturer's declaration'
Standards and Regulations
- Standards/specifications
- M12 connector IEC 61076-2-101
- Flammability rating according to UL 94
- HB
Other Categories
NanometersManometersFlowmetersSensorsAcceleration SensorsFiber Optic SensorsDetectorsUltrasonic SensorsTemperature & Humidity SensorsVibration SensorsLevel SensorsPressure SensorsProximity SensorsInductive SensorsMotion SensorsMagnetic Sensors GroupOptical SensorsCapacitive SensorsPhotoelectric SensorsPosition SensorsEncodersOther sensors and Accessories