Phoenix Contact
1437740
Bus system flush-type plug - SACCBP-MSD-4CON-PG9/2,0-931SCO - 1437740
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Send request for price
1
Payment methods:
Offer with manufacturer lead time
Ships in:On Request
Best price:
Send request for price
Additional Information
- Part Number
- 1437740
- UPC
- 4046356458481
Dimensions
- Length of cable
- 2 m
Material
- Flammability rating according to UL 94
- V0
- Contact material
- CuZn
- Contact surface material
- Ni/Au
- Contact carrier material
- PA 6.6
- Material, knurls
- Nickel-plated brass
- Sealing material
- NBR
Ambient conditions
- Ambient temperature (operation)
- -25 °C - 90 °C (Plug / socket)
- Degree of protection
- IP67 (When plugged in)
- Degree of protection
- IP65 (When plugged in)
Environmental Product Compliance
- REACh SVHC
- Lead 7439-92-1
- China RoHS
- Environmentally Friendly Use Period = 50 years
- China RoHS
- For details about hazardous substances go to tab 'Downloads', Category 'Manufacturer's declaration'
Standards and Regulations
- Flammability rating according to UL 94
- V0
Cable
- Cable type
- Ethernet flexible CAT5, 2-pair
- Cable type (abbreviation)
- 93E
- UL AWM style
- 20963 (80°C/30 V)
- Signal type/category
- Ethernet CAT5 (IEC 11801), 100 Mbps
- Cable structure
- 2x2xAWG26/7; SF/UTP
- Conductor cross section
- 2x 2x 0.14 mm²
- AWG signal line
- 26
- Conductor structure signal line
- 7x 0.16 mm
- Core diameter including insulation
- 0.98 mm
- Wire colors
- white/orange-orange, white/green-green
- Twisted pairs
- 2 cores to the pair
- Overall twist
- Two pairs with two fillers to the core
- Shielding
- Aluminum-coated foil, tinned copper braided shield
- Optical shield covering
- 70 %
- External sheath, color
- water blue RAL 5021
- Outer sheath thickness
- 1.2 mm
- External cable diameter D
- 6.4 mm ±0.2 mm
- Minimum bending radius, fixed installation
- 4 x D
- Minimum bending radius, flexible installation
- 8 x D
- Tensile strength GRP
- ≤ 80 N
- Cable weight
- 42 kg/km
- Outer sheath, material
- PUR
- Material conductor insulation
- Foamed PE
- Conductor material
- Bare Cu litz wires
- Standards/specifications
- Electrical requirements EN 50288-2-2
- Insulation resistance
- ≥ 500 MΩ*km
- Loop resistance
- ≤ 290.00 Ω/km
- Cable capacity
- approx. 45 nF/km (at 1 kHz)
- Wave impedance
- 100 Ω ±5 Ω (at 100 MHz)
- Near end crosstalk attenuation (NEXT)
- 65.3 dB (with 1 MHz)
- Near end crosstalk attenuation (NEXT)
- 56.3 dB (at 4 МHz)
- Near end crosstalk attenuation (NEXT)
- 50.3 dB (at 10 MHz)
- Near end crosstalk attenuation (NEXT)
- 47.2 dB (at 16 MHz)
- Near end crosstalk attenuation (NEXT)
- 45.8 dB (at 20 МHz)
- Near end crosstalk attenuation (NEXT)
- 42.9 dB (at 31.25 МHz)
- Near end crosstalk attenuation (NEXT)
- 38.4 dB (at 62.5 МHz)
- Near end crosstalk attenuation (NEXT)
- 35.3 dB (at 100 MHz)
- Power-summated near end crosstalk attenuation (PSNEXT)
- 62.3 dB (with 1 MHz)
- Power-summated near end crosstalk attenuation (PSNEXT)
- 53.3 dB (at 4 МHz)
- Power-summated near end crosstalk attenuation (PSNEXT)
- 47.3 dB (at 10 MHz)
- Power-summated near end crosstalk attenuation (PSNEXT)
- 44.2 dB (at 16 MHz)
- Power-summated near end crosstalk attenuation (PSNEXT)
- 42.8 dB (at 20 МHz)
- Power-summated near end crosstalk attenuation (PSNEXT)
- 39.9 dB (at 31.25 МHz)
- Power-summated near end crosstalk attenuation (PSNEXT)
- 35.4 dB (at 62.5 МHz)
- Power-summated near end crosstalk attenuation (PSNEXT)
- 32.3 dB (at 100 MHz)
- Attenuation
- 3.2 dB (with 1 MHz)
- Attenuation
- 6 dB (at 4 МHz)
- Attenuation
- 9.5 dB (at 10 MHz)
- Attenuation
- 12.1 dB (at 16 MHz)
- Attenuation
- 13.6 dB (at 20 МHz)
- Attenuation
- 17.1 dB (at 31.25 МHz)
- Attenuation
- 24.8 dB (at 62.5 МHz)
- Attenuation
- 32 dB (at 100 MHz)
- Return loss (RL)
- 23 dB (at 4 МHz)
- Return loss (RL)
- 24.1 dB (at 8 МHz)
- Return loss (RL)
- 25 dB (at 10 MHz)
- Return loss (RL)
- 25 dB (at 16 MHz)
- Return loss (RL)
- 25 dB (at 20 МHz)
- Return loss (RL)
- 23.6 dB (at 31.25 МHz)
- Return loss (RL)
- 21.5 dB (at 62.5 МHz)
- Return loss (RL)
- 20.1 dB (at 100 MHz)
- Signal runtime
- 5.3 ns/m
- Coupling resistance
- ≤ 100.00 mΩ/m (at 10 MHz)
- Nominal voltage, cable
- ≤ 100 V (Peak value, not for high-power applications)
- Test voltage Core/Core
- 700 V (50 Hz, 1 min.)
- Test voltage Core/Shield
- 700 V (50 Hz, 1 min.)
- Current carrying capacity of cable
- 2 A (according to DIN VDE 0891-1)
- Flame resistance
- according to IEC 60332-1-2
- Flame resistance
- in acc. to UL VW1
- Halogen-free
- according to IEC 60754-1
- Resistance to oil
- according to EN 60811-2-1
- Ambient temperature (operation)
- -40 °C - 80 °C (cable, fixed installation)
- Ambient temperature (operation)
- -20 °C - 80 °C (cable, flexible installation)
- Ambient temperature (installation)
- -20 °C - 80 °C
- Ambient temperature (storage/transport)
- -20 °C - 80 °C
Other Categories
ActuatorsBlocksCables, Pipes & HosesCompressorsControlCouplings & FittingsCylinders & PistonsElectronicsFiltersHVACIndustrial PC's & HMIsLightingLinear techniqueMotorsPower SupplyPower TransmissionPumps & ValvesRenewable energyRoboticsSeals, Rings & ConnectorsSensors & Measuring DevicesTools and AccessoriesCNCOther