EX-TR 335-11Z-3G/D...
- Part Number
- 101189290
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Send request for price
1
Payment methods:
Additional Information
- Part Number
- 101189290
- ETIM
- Group Code : EG000026
- Group Description : Sensors
- Class Description : End switch
- Class Code : EC000030
- Version : 7
Explosion protection
- Explosion protection: regulations
- EN IEC 60079-0 | EN IEC 60079-15 | EN IEC 60079-31
- Explosion protection zones
- 22 | 2
- Explosion protection category
- 3D | 3G
- Explosion protection designation
- II 3G Ex nC IIC T5 Gc X | II 3D Ex tc IIIC T90°C Dc X
- Manufacturer declaration
- Manufacturer declaration | Additional simple electrical apparatus (Zone 0 and 20)
Electrical data
- Thermal test current
- 10 A
- Utilisation category AC-15
- 230 VAC
- Utilisation category AC-15
- 4 A
- Utilisation category DC-13
- 24 VDC
- Utilisation category DC-13
- 4 A
- Switching element
- NO contact, NC contact
- Switching principle
- Slow action
- Bounce duration, maximum
- 2 ms
- Switching frequency
- 5,000 /h
- Material of the contacts, electrical
- Silver
Mechanical data - Dimensions
- Length of sensor
- 38 mm
- Width of sensor
- 40.5 mm
- Height of sensor
- 116.6 mm
Ambient conditions - Insulation values
- Rated insulation voltage U
- 500 V
- Rated impulse withstand voltage U
- 6 kV
Safety classification - Safety outputs
- B
- 20,000,000 Operations
General data - Features
- Safety functions
- Yes
- Number of auxiliary contacts
- 1
- Number of safety contacts
- 1
General data
- Housing construction form
- Norm construction design
- Actuator type to EN 50041
- C
- Enclosure material
- Aluminium
- Enclosure coating material
- painted
- Gross weight
- 240 g
Safety classification
- Standards
- EN ISO 13849-1
- Mission time
- 20 Year(s)
Ambient conditions
- Degree of protection
- IP67
- Ambient temperature
- -20 ... +60 °C
Mechanical data - Connection technique
- Termination
- Screw terminals M20 x 1.5
- Cable cross-section of the cable glands, minimum
- 7 mm
- Cable cross-section of the cable glands, maximum
- 12 mm
- Cable section, minimum
- 0.75 mm²
- Cable section, maximum
- 2.5 mm²
- Note (Cable section)
- All indications including the conductor ferrules.
- Wire cross-section
- 13 AWG
Mechanical data
- Actuating element
- Roller plunger
- Mechanical life, minimum
- 30,000,000 Operations
- Impact energy, maximum
- 4 J
- Actuating force, minimum
- 17 N
- Actuating speed, maximum
- 0.5 m/s
- Note (Actuating speed)
- Actuating speed with actuating angle 30° to switch axis
- Note (Switchover time)
- Switchover time in accordance with actuating speed
Other Categories
NanometersManometersFlowmetersSensorsAcceleration SensorsFiber Optic SensorsDetectorsUltrasonic SensorsTemperature & Humidity SensorsVibration SensorsLevel SensorsPressure SensorsProximity SensorsInductive SensorsMotion SensorsMagnetic Sensors GroupOptical SensorsCapacitive SensorsPhotoelectric SensorsPosition SensorsEncodersOther sensors and Accessories