The number in brackets indicate the PIN number of the connector.
Mechanical data - Dimensions
Length of sensor
13 mm
Width of sensor
88 mm
Height of sensor
25 mm
Scope of delivery
Scope of delivery
Actuator must be ordered separately.
Safety classification - Safety outputs
B
25,000,000 Operations
General data - Features
Integral system diagnostics, status
Yes
Number of normally closed (NC)
3
Number of safety contacts
2
General data
Standards
BG-GS-ET-14 | EN IEC 60947-5-3
Coding level according to EN ISO 14119
Low
Working principle
Magnetic drive
Installation conditions (mechanical)
quasi-flush
Enclosure material
Glass-fibre, reinforced thermoplastic
Gross weight
28 g
Safety classification
Standards
EN ISO 13849-1
Mission time
20 Year(s)
Ambient conditions
Degree of protection
IP67
Ambient temperature
-25 ... +70 °C
Storage and transport temperature, minimum
-25 °C
Storage and transport temperature, maximum
+70 °C
Resistance to vibrations
10 … 55 Hz, amplitude 1 mm
Restistance to shock
30 g / 11 ms
Mechanical data - Connection technique
Termination
Connector 8 mm, 6-pole, Latching interlocking
Mechanical data - Switching distances according EN IEC 60947-5-3
Note (Switching distance Sn)
Axial misalignment, a horizontal and vertical misalignment of the safety sensor and the actuator are tolerated. The possible misalignment depends on the distance of the active surfaces of the sensor and the actuator. The sensor remains active within the tolerance range.