SINAMICS G120C RATED POWER 7,5KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-2...
6SL3210-1KE21-7UP1
6SL3210-1KE21-7UP1

Description

ActiveRoHS Compliant
SINAMICS g120c rated power 7,5KW with 150% overload for 3 sec 3AC380-480v +10/-20% 47-63HZ unfiltered i/o-interface 6di, 2do,1ai,1ao safe torque off integrated fieldbus PROFIBUS-dp protection IP20/ ul open type size fsb 196x100x203(hxwxd) external 24v
Country of Origin
GB
Part Number
6SL3210-1KE21-7UP1
Tariff Code
85044095
EAN
4042948663493
€707.40
net
€786.00
Free Shipping!
1
Payment methods:
Best offer from:
NLTrusted Automa.Net Supplier
Availability:
1 pc.
In-Stock
Warranty:
24 months
Estimated Delivery:
22-22 October to United Kingdom
Condition:
New Factory Sealed
New Factory Sealed - A brand-new, unused, unopened, undamaged item in its original packaging, factory sealed.
Shipping Information

Additional Information

Part Number
6SL3210-1KE21-7UP1
UPC
887621019181
Tariff Code
85044095
Country of Origin
GB
ETIM
Group Code : EG000017
Group Description : Low-voltage Industrial Components
Class Description : Frequency converter =< 1 kV
Class Code : EC001857
Version : 7

Specifications

Country of Origin
GB
Depth
203 mm
Width
100 mm
Height
196 mm
Mains voltage
380 V
With PC connection
true
Max. output voltage
480 V
Number of phases input
3
Number of phases output
3
Number of digital inputs
6
Max. output frequency
550 Hz
Number of analogue inputs
1
Number of digital outputs
2
Number of analogue outputs
1
Number of HW-interfaces USB
1
Type of converter
U converter
Degree of protection (IP)
IP20
Nominal output current I2N
17 A
Number of HW-interfaces other
6
Number of interfaces PROFINET
0
Number of HW-interfaces RS-232
1
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-485
0
Number of HW-interfaces parallel
0
Integrated breaking resistance
true
Number of HW-interfaces serial TTY
1
Supporting protocol for PROFIBUS
true
Number of HW-interfaces industrial Ethernet
0
Relative symmetric net frequency tolerance
5 %
Relative symmetric net voltage tolerance
-20 %
Supporting protocol for other bus systems
true
Max. output at linear load at rated output voltage
5.5 kW
Application in domestic- and commercial area permitted
true
Max. output at quadratic load at rated output voltage
7.5 kW