Need more information?

Call us at:+48 17 778 34 19

Weidmuller 8473010000MCZ PT100/3 CLP 0...200C

1 / 4
8473010000 Weidmuller, Other
Reference Image - Not actual item!
8473010000 Weidmuller, Other
Reference Image - Not actual item!
8473010000 Weidmuller, Other
Reference Image - Not actual item!
8473010000 Weidmuller, Other
Reference Image - Not actual item!
8473010000 Weidmuller, Other
8473010000 Weidmuller, Other
8473010000 Weidmuller, Other
8473010000 Weidmuller, Other

Offer Description

TEMP TRANSDUCER FOR PT100,0 TO 200 DEG C

Description

Choose MCZ PT100/3 CLP 0...200C by Weidmuller for your next project and benefit from a product that combines quality, efficiency, and value in one package.

Identify this product by its MPN: 8473010000, the unique identifier that ensures you're getting the exact component you need for your application.

Ready to ship: 57 pieces in stock. Secure your order today for prompt delivery.

This product is offered in New Factory Sealed condition, guaranteeing you receive a solution that meets your expectations for quality and reliability.

This product comes with warranty: 12 months.

Order now to experience the advantages of working with a trusted supplier. Our team is ready to assist you at every step, from selection to after-sales support. Join our satisfied customers and elevate your business with reliable, high-quality products from our portfolio.

Product Details

Part Number
8473010000
$86.62
excl. tax
Supplier Price
€79.47
Payment methods:

Offer details

Best offer from:
Trusted Automa.Net Supplier
Availability:
57 pcs.
In-Stock
Updated at: 12-06-2025
Warranty:
12 months
Estimated Delivery:
On Request
Condition:
New Factory Sealed
New Factory Sealed - A brand-new, unused, unopened, undamaged item in its original manufacturer-sealed packaging.
The Seller is responsible for shipping the product and invoicing

Are you a Supplier?

Join 650 suppliers, sell to 3500+ verified buyers.

Sign up now

Policies and Information

Shipping Information

Return & Refund Policies

Secure Payment Process

Warranty Policies

General Data

Accuracy
Typ.: 0.2 %, máx. 0.5 % v. FSR
Configuration
none
Galvanic isolation
between input/output
Input/Output
PT100/ 4...20 mA (current loop)
Linearity
Yes
Rail
TS 35
Step response time
10 ms
Temperature coefficient
max. ± 250 ppm/K
Voltage supply
Output loop powered, max. 30 V/ min. 9 V + (20 mA x RL)

Probability Of Failure

MTTF
1,068 Years

Approvals

Approvals
CE, CSA, cURus, EAC
ROHS
Conform
UL File Number Search
E141197

Dimensions And Weights

Length
91 mm
Length (inches)
3.583 inch
Width
6 mm
Width (inches)
0.236 inch
Depth
63.2 mm
Depth (inches)
2.488 inch
Net weight
26.4 g

Connection Data

Type of connection
Tension-clamp connection
Clamping range, rated connection
1.5 mm²
Clamping range, min.
0.5 mm²
Clamping range, max.
1.5 mm²
Wire connection cross section AWG, min.
AWG 26
Wire connection cross section AWG, max.
AWG 16
Wire cross-section, solid, min.
0.5 mm²
Wire cross-section, solid, max.
1.5 mm²
Wire connection cross-section, finely stranded, min.
0.5 mm²
Wire connection cross section, finely stranded, max.
1.5 mm²
Wire cross-section, finely stranded, min. (AWG)
AWG 26
Wire cross-section, finely stranded, max. (AWG)
AWG 16
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.
0.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.
1.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.
0.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.
1.5 mm²

Rated Data Ul

Certificate No. (cURus)
E141197

Tender Specification Sheets

Long specification
PT100 temperature measuring transformer, output-loop powered,3-wire connection technologyRTD measuring transformer in 6 mm width, 4...20 mA output-loop poweredwithout electrical isolation, for transmitting PT100 2-/3-wire signals.Input temperature range 0...+200 °C. Add-on housing for TS35 rail mountingDimensions: L/W/H 91/ 6/ 63.2 mmTension-clamp connection / Nominal cross-section 1.5 mm2Protection degree: IP 20 Input PT100, 2-/3-wireOutput 4...20 mALoad resistance Transmission error Auxiliary power via 4...20 mA current loopAmbient temperature range 0°C...+50 °C< 0,2 % v. E.Isolation no electrical isolationApprovals cURus, CSATypeMCZ PT100/3 CLP 0...200C
Short specification
PT100 temperature measuring transformer, output-loop powered,3-wire connection technologyRTD measuring transformer in 6 mm width, 4...20 mA output-loop poweredwithout electrical isolation, for transmitting PT100 2-/3-wire signals.Input temperature range 0...+200 °C.

Input

Number of inputs
1
Sensor
PT100/2-/3-wire (in compliance with IEC 751)
Sensor supply
0.8 mA / 9…30 V DC
Temperature input range
0...200 °C

Classifications

ETIM 6.0
EC002919
ETIM 7.0
EC002919
EClass 9.0
27-21-01-29
EClass 9.1
27-21-01-29
EClass 10.0
27-21-01-29
UNSPSC
30-21-18-01

Output

Number of outputs
1
Output current
4...20 mA (current loop) at 9...30V DC
Load impedance current
≤ 600 Ω

Environmental Product Compliance

REACH SVHC
Lead 7439-92-1

Insulation Coordination

EMC standards
EN 61000-6
Galvanic isolation
between input/output
Pollution severity
2
Rated voltage
50 V
Surge voltage category
I

Temperatures

Operating temperature, max.
50 °C
Operating temperature, min.
-25 °C
Storage temperature, max.
85 °C
Storage temperature, min.
-25 °C
Operating temperature
-25 °C...50 °C
Storage temperature
-25 °C...85 °C