Electrical data

Thermal test current
10 A
Rated control voltage
24 VAC/DC
Electrical power consumption, maximum
10 W
Switching principle
slow action, positive break NC contact
Switching frequency
1,000 /h
Material of the contacts, electrical
Silver

Mechanical data - Dimensions

Length of sensor
50 mm
Width of sensor
87 mm
Height of sensor
192 mm

Ambient conditions - Insulation values

Rated insulation voltage U
400 V
Rated impulse withstand voltage U
2.5 kV

Electrical data - Safety contacts

Voltage, Utilisation category AC-15
230 VAC
Current, Utilisation category AC-15
8 A
Voltage, Utilisation category DC-13
24 VDC
Current, Utilisation category DC-13
5 A

Scope of delivery

Scope of delivery
Actuator must be ordered separately.

Safety classification - Safety outputs

B
2,000,000 Operations
B
1,000,000 Operations

Electrical data - Magnet control

Magnet switch-on time
100 %
Test pulse duration, maximum
5 ms
Test pulse interval, minimum
50 ms

General data - Features

Number of actuating directions
3
Number of auxiliary contacts
2
Number of safety contacts
2

General data

Standards
EN ISO 13849-1 | EN ISO 14119 | EN IEC 60947-5-1
Coding level according to EN ISO 14119
Low
Working principle
electromechanical
Enclosure material
Aluminium
Gross weight
1,465 g

Electrical data - Auxiliary contacts

Voltage, Utilisation category AC-15
230 VAC
Current, Utilisation category AC-15
8 A
Voltage, Utilisation category DC-13
24 VDC
Current, Utilisation category DC-13
5 A

Safety classification

Standards
EN ISO 13849-1
Mission time
20 Year(s)

Ambient conditions

Degree of protection
IP67
Ambient temperature
+0 ... +50 °C
Permissible installation altitude above sea level, maximum
2,000 m

Mechanical data - Connection technique

Termination
Screw terminals
Cable section, minimum
0.25 mm²
Cable section, maximum
2.5 mm²
Note (Cable section)
All indications including the conductor ferrules.

Mechanical data

Mechanical life, minimum
2,000,000 Operations
Holding force F
3,000 N
Holding force F
4,000 N
Latching force
20 N
Positive break force, minimum
20 N
Actuating speed, maximum
0.3 m/s

Approvals - Standards

Certificates
cULus | CCC