Electrical data - Relay outputs (auxiliary contacts)

Switching capacity, maximum
24 VDC
Switching capacity, maximum
2 A

Electrical data

Frequency range
50 Hz | 60 Hz
Operating voltage
24 VDC -15 % / +15 %
Thermal test current
5 A
Rated operating voltage
24 VDC
Operating current
100 mA
Rated AC voltage for controls, 50 Hz, minimum
20.4 VAC
Rated control voltage at AC 50 Hz, maximum
26.4 VAC
Rated AC voltage for controls, 60 Hz, minimum
20.4 VAC
Rated control voltage at AC 60 Hz, maximum
26.4 VAC
Rated AC voltage for controls at DC minimum
20.4 VDC
Rated control voltage at DC, maximum
27.6 VDC
Electrical power consumption
2.5 W
Contact resistance, maximum
0.1 Ω
Note (Contact resistance)
in new state
Drop-out delay in case of power failure, typically
80 ms
Drop-out delay in case of emergency, typically
20 ms
Pull-in delay at automatic start, maximum, typically
100 ms
Pull-in delay at RESET, typically
20 ms
Material of the contacts, electrical
AgCdO

Note

Note (General)
Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit.

Mechanical data - Dimensions

Width
48 mm
Height
96 mm
Depth
58 mm

Ambient conditions - Insulation values

Rated impulse withstand voltage U
4.8 kV
Overvoltage category
III
Degree of pollution
2

General data - Features

Stop-Category
0
Wire breakage detection
Yes
Cross-circuit detection
Yes
Automatic reset function
Yes
Reset after disconnection of supply voltage
Yes
Integral system diagnostics, status
Yes
Number of LEDs
1
Number of normally closed (NC)
4
Number of normally open (NO)
2
Number of safety contacts
1

General data

Standards
BG-GS-ET-14 | BG-GS-ET-20 | EN IEC 62061 | EN ISO 13849-1 | EN IEC 60947-5-1 | EN IEC 60947-5-3 | EN IEC 60947-5-5 | EN IEC 60204-1 | EN IEC 60947-1
Enclosure material
Glass-fibre, reinforced thermoplastic
Gross weight
125 g

Safety classification

Standards
EN ISO 13849-1 | EN IEC 61508
Performance Level, up to
d
Category
3
PFH value
1.00 x 10⁻⁷ /h
Notice
for max. 50,000 switching cycles/year and max. 80% contact load
Safety Integrity Level (SIL), suitable for applications in
2
Mission time
20 Year(s)

Wiring example

Note (Wiring diagram)
To secure one or a number of guard doors up to PL c and Category 1 | Monitoring a number of guard doors using magnetic safety sensors BNS range | The wiring diagram is shown with guard doors closed and in de-energised condition. | Monitoring further guard doors: Further magnetic safety sensors can be connected to S2 in a similar way to those on S1.

Other data

Note (applications)
Safety sensor | Guard system

Ambient conditions

Degree of protection of the enclosure
IP40
Degree of protection of the mounting space
IP54
Degree of protection of clips or terminals
IP20
Ambient temperature
+0 ... +55 °C
Storage and transport temperature, minimum
-25 °C
Storage and transport temperature, maximum
+70 °C
Resistance to vibrations
10...55 Hz, Amplitude 0.35 mm, ± 15 %
Restistance to shock
30 g / 11 ms

Mechanical data - Connection technique

Termination
rigid or flexible | Screw terminals M20 x 1.5
Cable section, maximum
1.5 mm²

Electrical data - Safe relay outputs

Voltage, Utilisation category AC-15
230 VAC
Current, Utilisation category AC-15
6 A
Voltage, Utilisation category DC-13
24 VDC
Current, Utilisation category DC-13
6 A
Switching capacity, minimum
10 VDC
Switching capacity, minimum
10 mA
Switching capacity, maximum
250 VAC
Switching capacity, maximum
8 A

Mechanical data

Mechanical life, minimum
50,000,000 Operations
Mounting
Snaps onto standard DIN rail to EN 60715

Specifications

Width
48 mm
Height
96 mm
Depth
58 mm

Approvals - Standards

Certificates
cULus

Electrical data - Electromagnetic compatibility (EMC)

EMC rating
EN 61000-4-3 | EN 61000-4-6 | IEC 61000-6-2

Electrical data - Digital inputs

Conduction resistance, maximum
40 Ω

Status indication

Indicated operating states
Authorised operation