Schmersal

101128981

AES 1102 24 VDC
101128981
101128981
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:

Additional Information

Part Number
101128981
ETIM
Group Code : EG000019
Group Description : Relays
Class Description : Device for monitoring of safety-related circuits
Class Code : EC001449
Version : 7

Electrical data - Relay outputs (auxiliary contacts)

Switching capacity, maximum
24 VDC
Switching capacity, maximum
2 A

Electrical data

Frequency range
50 Hz | 60 Hz
Operating voltage
24 VDC -15 % / +15 %
Thermal test current
4 A
Rated operating voltage
24 VDC
Rated AC voltage for controls at DC minimum
20.4 VDC
Rated control voltage at DC, maximum
27.6 VDC
Electrical power consumption
2.4 W
Contact resistance, maximum
0.1 Ω
Note (Contact resistance)
in new state
Drop-out delay in case of power failure, typically
80 ms
Drop-out delay in case of emergency, typically
20 ms
Pull-in delay at automatic start, maximum, typically
100 ms
Pull-in delay at RESET, typically
20 ms
Material of the contacts, electrical
AgCdO

Note

Note (General)
Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit.

Mechanical data - Dimensions

Width
22.5 mm
Height
75 mm
Depth
110 mm

Ambient conditions - Insulation values

Rated impulse withstand voltage U
4 kV
Overvoltage category
III
Degree of pollution
2

Electrical data - Digital Output

Voltage, Utilisation category DC-12
24 VDC
Current, Utilisation category DC-12
0.1 A

General data - Features

Stop-Category
0
Wire breakage detection
Yes
Automatic reset function
Yes
Reset after disconnection of supply voltage
Yes
Integral system diagnostics, status
Yes
Number of LEDs
1
Number of normally closed (NC)
4
Number of normally open (NO)
2
Number of safety contacts
1

General data

Standards
BG-GS-ET-14 | BG-GS-ET-20 | EN IEC 62061 | EN ISO 13849-1 | EN IEC 60947-5-1 | EN IEC 60947-5-3 | EN IEC 60947-5-5 | EN IEC 60204-1 | EN IEC 60947-1
Climatic stress
EN 60068-2-3 | BG-GS-ET-14
Enclosure material
Glass-fibre reinforced thermoplastic, ventilated
Gross weight
120 g

Safety classification

Standards
EN ISO 13849-1 | EN IEC 61508
Performance Level, up to
c
Category
1
PFH value
1.14 x 10⁻⁶ /h
Notice
for max. 50,000 switching cycles/year and max. 80% contact load
Safety Integrity Level (SIL), suitable for applications in
1
Mission time
20 Year(s)

Wiring example

Note (Wiring diagram)
To secure one or a number of guard doors up to PL c and Category 1 | Monitoring a number of guard doors using magnetic safety sensors BNS range | The wiring diagram is shown with guard doors closed and in de-energised condition.

Other data

Note (applications)
Safety sensor | Guard system

Ambient conditions

Degree of protection of the enclosure
IP40
Degree of protection of the mounting space
IP54
Degree of protection of clips or terminals
IP20
Ambient temperature
+0 ... +55 °C
Storage and transport temperature, minimum
-25 °C
Storage and transport temperature, maximum
+70 °C
Resistance to vibrations
10...55 Hz, Amplitude 0.35 mm, ± 15 %
Restistance to shock
30 g / 11 ms

Mechanical data - Connection technique

Termination
rigid or flexible | Screw terminals M20 x 1.5
Terminal designations
IEC/EN 60947-1
Cable section, maximum
2.5 mm²
Tightening torque of Clips
0.6 Nm

Electrical data - Safe relay outputs

Voltage, Utilisation category AC-15
250 VAC
Current, Utilisation category AC-15
1.5 A
Voltage, Utilisation category DC-13
24 VDC
Current, Utilisation category DC-13
1 A
Switching capacity, minimum
10 VDC
Switching capacity, minimum
10 mA
Switching capacity, maximum
250 VAC
Switching capacity, maximum
8 A

Mechanical data

Mechanical life, minimum
3,000,000 Operations
Mounting
Snaps onto standard DIN rail to EN 60715

Specifications

Width
22.5 mm
Height
75 mm
Depth
110 mm

Approvals - Standards

Certificates
BG | cULus

Electrical data - Electromagnetic compatibility (EMC)

EMC rating
EMC-Directive

Electrical data - Digital inputs

Conduction resistance, maximum
40 Ω

Status indication

Indicated operating states
Authorised operation