Electrical data

Thermal test current
10 A
Required rated short-circuit current
1,000 A
Switching element
NO contact, NC contact
Switching principle
slow action, positive break NC contact
Switching frequency
2,000 /h
Material of the contacts, electrical
Silver

Note

Note (General)
minimum actuating radius on rotating guard systems via the narrow edge of the actuator 140 mm | minimum actuating radius on hinged guards in line with the plane of the actuator 200 mm | The axis of the hinge must be 13 mm above and in a parallel plane to the top surface of the safety switch. | The actuator is not available separately.

Mechanical data - Dimensions

Length of sensor
30 mm
Width of sensor
30 mm
Height of sensor
85 mm

Ambient conditions - Insulation values

Rated insulation voltage U
250 VAC
Rated impulse withstand voltage U
4 kV
Overvoltage category
III
Degree of pollution
3

Electrical data - Safety contacts

Voltage, Utilisation category AC-15
230 VAC
Current, Utilisation category AC-15
4 A
Voltage, Utilisation category DC-13
24 VDC
Current, Utilisation category DC-13
4 A

Scope of delivery

Scope of delivery
Not available as spare part | Slot cover for dust-proof covering of the opening not in use

Safety classification - Safety outputs

B
2,000,000 Operations
B
1,000,000 Operations
Note (B
at 10% I | and ohmic load

General data - Features

Number of actuating directions
2
Number of auxiliary contacts
1
Number of cable glands
1
Number of safety contacts
1

General data

Standards
EN ISO 13849-1 | EN ISO 14119 | EN IEC 60947-5-1
Coding level according to EN ISO 14119
High
Working principle
electromechanical
Enclosure material
Plastic, glass-fibre reinforced thermoplastic, self-extinguishing
Material of the actuator
Stainless steel
Gross weight
100 g

Electrical data - Auxiliary contacts

Voltage, Utilisation category AC-15
230 VAC
Current, Utilisation category AC-15
4 A
Voltage, Utilisation category DC-13
24 VDC
Current, Utilisation category DC-13
4 A

Safety classification

Standards
EN ISO 13849-1 | EN IEC 60947-5-1
Mission time
20 Year(s)

Ambient conditions

Degree of protection
IP67
Ambient temperature
-30 ... +80 °C
Storage and transport temperature, minimum
-30 °C
Storage and transport temperature, maximum
+85 °C
Permissible installation altitude above sea level, maximum
2,000 m

Mechanical data - Connection technique

Termination
Connector M12

Mechanical data

Mechanical life, minimum
1,000,000 Operations
Latching force
5 N
Positive break travel
11 mm
Positive break force per NC contact, minimum
17 N
Actuating speed, maximum
2 m/s
Mounting
Screws
Type of the fixing screws
2x M5

Approvals - Standards

Certificates
BG | cULus