Safety appraisal

Standards
EN ISO 13849-1
Mission Time
20 Year(s)

Electrical data

Thermal test current
10 A
Required rated short-circuit current to EN 60947-5-1
1,000 A
Utilisation category AC-15
230 VAC
Utilisation category AC-15
4 A
Utilisation category DC-13
24 VDC
Utilisation category DC-13
1 A
Switching element
Normally open contact (NO)
Switching principle
Slow action with staggered contacts
Switching frequency
5,000 /h

Mechanical data - Dimensions

Length of sensor
46 mm
Width of sensor
30 mm
Height of sensor
110.5 mm

Ambient conditions - Insulation value

Rated insulation voltage U
500 V
Rated impulse withstand voltage U
6 kV

General data - Features

Number of auxiliary contacts
2

General data

Standards
IEC 60947-5-1 | EN ISO 13849-1 | BG-GS-ET-15
Housing construction form
Norm construction design
Actuator type to DIN EN 50047
A
Enclosure material
Zinc die-cast, paint finish
Material of the contacts, electrical
Silver
Lever material
Metal film
Roller material
Plastic
Gross weight
195 g

Ambient conditions

Degree of protection
IP65 to EN 60529 | IP67 to EN 60529
Ambient temperature, minimum
-30 °C
Ambient temperature, maximum
+80 °C

Mechanical data - Connection technique

Terminal Connector
Screw terminals M20 x 1.5
Cable section, minimum
0.75 mm²
Cable section, maximum
2.5 mm²
Note (Cable section)
All indications about the cable section are including the conductor ferrules.

Mechanical data

Actuating element
Roller lever
Mechanical life, minimum
20,000,000 Operations
Actuating speed, minimum
4,122 mm/min
Actuating speed, maximum
1 m/s
Note (Actuating speed)
Actuating speed with actuating angle 30° to switch axis
Note Bounce duration
Bounce duration in accordance with actuating speed
Note (Switchover time)
Switchover time in accordance with actuating speed
Actuating torque, minimum
0.2 Nm
Positive break torque
0.2 Nm

Approval - Standards

Certificates
cULus | cCSAus | CCC | EAC