Schmersal

101147342

T4V7H 336-02Z-2079-2
101147342
101147342
101147342
101147342
101147342
101147342
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

Safety appraisal

Standards
BG-GS-ET-15 | EN ISO 13849-1 | EN 60947-5-1
Mission Time
20 Year(s)

Electrical data

Thermal test current
10 A
Required rated short-circuit current to EN 60947-5-1
1,000 A
Utilisation category AC-15
230 VAC
Utilisation category AC-15
4 A
Utilisation category DC-13
24 VDC
Utilisation category DC-13
4 A
Switching element
Opener (NC)
Switching principle
Creep circuit element
Bounce duration, maximum
2 ms
Switching frequency
5,000 /h

Mechanical data - Dimensions

Length of sensor
38 mm
Width of sensor
40.5 mm
Height of sensor
176.5 mm

Ambient conditions - Insulation value

Rated insulation voltage U
500 V
Rated impulse withstand voltage U
6 kV

Safety appraisal - Safety outputs

B10d Normally-closed contact (NC)
20,000,000 Operations

General data - Features

Suitable for elevators
Yes
Safety functions
Yes
Number of safety contacts
2

General data

Housing construction form
Norm construction design
Enclosure material
Plastic, glass-fibre reinforced thermoplastic, self-extinguishing
Material of the contacts, electrical
Silver
Lever material
Metal film
Roller material
rubber
Gross weight
195 g

Ambient conditions

Ambient temperature, minimum
-30 °C
Ambient temperature, maximum
+80 °C

Mechanical data - Connection technique

Terminal Connector
Screw terminals M20 x 1.5
Cable section, minimum
0.75 mm²
Cable section, maximum
2.5 mm²
Note (Cable section)
All indications about the cable section are including the conductor ferrules.

Mechanical data

Actuating element
Roller lever
Mechanical life, minimum
30,000,000 Operations
Actuating speed, maximum
2.5 m/s
Note (Actuating speed)
Actuating speed with actuating angle 30° to switch axis
Note (Switchover time)
Switchover time in accordance with actuating speed
Actuating torque, minimum
0.3 Nm

Approval - Standards

Certificates
cULus | CCC | EAC