AZ 16 ZVK-M20
101157378
101157378
101157378
101157378
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:

Safety appraisal

Standards
BG-GS-ET-15 | EN ISO 13849-1 | EN 60947-5-1
Mission Time
20 Year(s)

Electrical data

Thermal test current
10 A
Switching element
NO contact, NC contact
Switching principle
Creep circuit element

Mechanical data - Dimensions

Length of sensor
30 mm
Width of sensor
52 mm
Height of sensor
90 mm

Electrical data - Safety contacts

Voltage, Utilisation category AC-15
230 VAC
Current, Utilisation category AC-15
4 A
Voltage, Utilisation category DC-13
24 VDC
Current, Utilisation category DC-13
4 A

Scope of delivery

Included in delivery
Actuators must be ordered separately.

Ambient conditions - Insulation value

Rated insulation voltage U
500 V
Rated impulse withstand voltage U
6 kV

Safety appraisal - Safety outputs

B10d Normally-closed contact (NC)
2,000,000 Operations
B10d Normally open contact (NO)
1,000,000 Operations
Note (B10d Normally open contact (NO))
at 10% I | and ohmic load

General data - Features

Ejection force
Yes
Number of auxiliary contacts
1
Number of cable glands
3
Number of safety contacts
1

General data

Coding level according to ISO 14119
Low
Enclosure material
Plastic, glass-fibre reinforced thermoplastic, self-extinguishing
Material of the contacts, electrical
Silver
Gross weight
115 g

Electrical data - Auxiliary contacts

Voltage, Utilisation category AC-15
230 VAC
Current, Utilisation category AC-15
4 A
Voltage, Utilisation category DC-13
24 VDC
Current, Utilisation category DC-13
4 A

Ambient conditions

Degree of protection
IP67 to EN 60529
Ambient temperature, minimum
-30 °C
Ambient temperature, maximum
+80 °C

Mechanical data - Connection technique

Terminal Connector
Screw terminals M20 x 1.5
Cable entry
3 x M20 x 1,5
Cable section, minimum
0.25 mm²
Cable section, maximum
2.5 mm²
Note (Cable section)
All indications about the cable section are including the conductor ferrules.

Mechanical data

Mechanical life, minimum
1,000,000 Operations
Positive break travel
8 mm
Positive break force, minimum
10 N
Actuating speed, maximum
2 m/s

Approval - Standards

Certificates
TÜV | cULus | CCC | EAC