Schmersal

101158200

SRB308IT-24VAC/DC
101158200
101158200
101158200
101158200
101158200
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:

Electrical data

Frequency range
50 Hz | 60 Hz
Operating voltage
24 VAC -15 % / +10 % | 24 VDC -15 % / +20 %
Ripple voltage
10 %
Rated operating voltage
24 VAC
Rated operating voltage
24 VDC
Operating current
125 mA
Rated AC voltage for controls, 50 Hz, minimum
20.4 VAC
Rated control voltage at AC 50 Hz, maximum
26.4 VAC
Rated AC voltage for controls, 60 Hz, minimum
20.4 VAC
Rated control voltage at AC 60 Hz, maximum
26.4 VAC
Rated AC voltage for controls at DC minimum
20.4 VDC
Rated control voltage at DC, maximum
28.8 VDC
Utilisation category AC-15
230 VAC
Utilisation category AC-15
1.5 A
Utilisation category DC-13
24 VDC
Utilisation category DC-13
1.2 A
Electrical power consumption
3 W
Electrical power consumption
3 VA
Contact resistance, maximum
0.1 Ω
Note (Contact resistance)
in new state
Drop-out delay in case of "emergency stop", maximum
15 ms
Pull-in delay at automatic start, maximum, typically
60 ms
Pull-in delay at RESET, typically
200 ms
Material of the contacts, electrical
AgSn0, Ag-Ni, self-cleaning, positive drive

Note

Note (General)
Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit.

Mechanical data - Dimensions

Width
45 mm
Height
100 mm
Depth
121 mm

Ambient conditions - Insulation values

Rated impulse withstand voltage U
4 kV
Overvoltage category
III
Degree of pollution
2

General data - Features

Stop-Category
0
Electronic Fuse
Yes
Wire breakage detection
Yes
Cross-circuit detection
Yes
Removable Terminals
Yes
Start input
Yes
Feedback circuit
Yes
Automatic reset function
Yes
Reset edge detection
Yes
Earth connection detection
Yes
Integral system diagnostics, status
Yes
Number of auxiliary contacts
2
Number of LEDs
5
Number of normally closed (NC)
2
Number of undelayed semi-conductor outputs with signaling function
6
Number of safety contacts
3
Number of signalling outputs
6

General data

Standards
EN IEC 62061 | EN ISO 13849-1 | EN IEC 60947-5-1 | EN IEC 60947-5-3 | EN IEC 60947-5-5 | EN IEC 61508 | EN IEC 60204-1 | EN IEC 60947-1
Climatic stress
EN 60068-2-78
Enclosure material
Glass-fibre reinforced thermoplastic, ventilated
Gross weight
480 g

Safety classification

Standards
EN IEC 60947-5-1 | EN IEC 61508
Mission time
20 Year(s)
Common Cause Failure (CCF), minimum
65
Performance Level, stop 0, up to
e
Category, Stop 0
4
Diagnostic Coverage (DC) Level, Stop 0
≥ 99 %
PFH value, Stop 0
2.00 x 10⁻⁸ /h
Safety Integrity Level (SIL), Stop 0, suitable for applications in
3

Wiring example

Note (Wiring diagram)
The wiring diagram is shown with guard doors closed and in de-energised condition. | The ISD tables (Intergral System Diagnostics) for analysis of the fault indications and their causes are shown in the appendix. | Relay outputs: Suitable for 2 channel control, for increase in capacity or number of contacts by means of contactors or relays with positive-guided contacts. | The control recognises cross-short, cable break and earth leakages in the monitoring circuit. | Connect potential p-type outputs of safety light grids/curtains to S12/S22. The devices must have the same reference potential. | 2 channel control shown for a guard-door monitor with two contacts, of which at least one contact has positive break, with external reset button (R) and feedback circuit (H2). (example without cross-wire monitoring) | For 2-channel control with cross-wire monitoring, connect the NC contact to S11/S12 and S31/S32 and bridge S21/S22 | For 1-channel control, connect NC contact to S11/S12 and bridge S21/S22 and S31/S32 | "Start function / Reset button: The function "trailing edge" is programmed by means of the "AF" switch located underneath the housing cover (switch position = 1). The automatic start is programmed by bridging terminals X3/X5 and by switching the "AF" switch to 0. The time offset between the channels is approx. 100 ms. An endless time offset between the channels 1 and 2 is programmed by bridging the terminals X3/X6." | F1 = Hybrid fuse | F2 = Fuse for signalling outputs

Other data

Note (applications)
Guard system | Pull-wire emergency stop switches | Safety light curtain | Emergency stop button

Ambient conditions

Degree of protection of the enclosure
IP40
Degree of protection of the mounting space
IP54
Degree of protection of clips or terminals
IP20
Ambient temperature
-25 ... +45 °C
Storage and transport temperature, minimum
-40 °C
Storage and transport temperature, maximum
+85 °C
Resistance to vibrations
10 ... 55 Hz, Amplitude 0.35 mm
Restistance to shock
30 g / 11 ms

Mechanical data - Connection technique

Termination
rigid or flexible | Screw terminals M20 x 1.5
Terminal designations
IEC/EN 60947-1
Cable section, minimum
0.25 mm²
Cable section, maximum
2.5 mm²
Tightening torque of Clips
0.6 Nm

Mechanical data

Mechanical life, minimum
10,000,000 Operations
Mounting
Snaps onto standard DIN rail to EN 60715

Specifications

Width
45 mm
Height
100 mm
Depth
121 mm

Approvals - Standards

Certificates
cULus

Electrical data - Electromagnetic compatibility (EMC)

EMC rating
EMC-Directive

Electrical data - Digital inputs

Conduction resistance, maximum
40 Ω

Status indication

Indicated operating states
Position relay K2 | Position relay K1 | Internal operating voltage U | Position relay K3