Electrical data

Current consumption
50 mA
Current consumption, maximum
500 mA

Electrical data - AS-Interface specification

AS-i Version
V 2.1
AS-i Profile
S-7.B.F.E
AS-i, IO-Code
0x7
AS-i, ID-Code
0xB
AS-i, ID-Code1
0xF
AS-i, ID-Code2
0xE
AS-i Input, Channel 1
Data bits DI 0 / DI 1 = dynamic code transmission
AS-i Input, Channel 2
Data bits DI 2 / DI 3 = dynamic code transmission
AS-i Outputs, DO 0
Solenoid control
AS-i Outputs, DO 1
No Function
AS-i Outputs, DO 2
No Function
AS-i Outputs, DO 3
No Function
AS-i Parameter bits, P0 ... P3
No function
Note (AS-i Parameter bits)
Set the parameter outputs to "1111" (0xF) | FID: periphery error
AS-i Input module address
0
Note (AS-i Input module address)
Preset to address 0, can be changed through AS-interface bus master or hand-held programming device

Mechanical data - Dimensions

Diameter of sensor
28 mm
Height of sensor
86.5 mm

Pin assignment

Connection
AS-i connection
PIN 1
AS-i +
PIN 2
(Aux -)
PIN 3
AS-Interface -
PIN 4
(Aux +)
Connection
Sensor connection
PIN 1
Brown - Normally open contact (NO)
PIN 2
Blue - Normally open contact (NO)
PIN 3
White - Opener (NC)
PIN 4
Black - Opener (NC)
PIN 5
Red - Magnet (+) AUS
PIN 6
Grey - Solenoid GND

Ambient conditions - Insulation values

Rated insulation voltage U
32 VDC
Rated impulse withstand voltage U
0.8 kV
Overvoltage category
III
Degree of pollution
3

General data - Features

Cross-circuit detection
Yes
Integral system diagnostics, status
Yes
Number of inputs for NC
1
Number of inputs for NO
1
Number of pre-wired cable
1

General data

Standards
EN 50295 | EN ISO 13849-1 | EN IEC 60947-5-1 | EN IEC 61508
Connector (electric)
Sensor connection: pre-wired cable 6-pole | AS-i connection: connector plug M12, 4-pole
Enclosure material
Plastic, glass-fibre reinforced thermoplastic, self-extinguishing
Gross weight
120 g

Safety classification

Standards
EN IEC 61508
Performance Level, up to
e
Category
4
PFH value
2.04 x 10⁻⁹ /h
Safety Integrity Level (SIL), suitable for applications in
3
Mission time
20 Year(s)

Electrical data - AS Interface

Rated operating voltage
26.5 ... 31.6 VDC (Protection against polarity reversal)

Ambient conditions

Degree of protection
IP67
Ambient temperature
-25 ... +55 °C
Storage and transport temperature, minimum
-25 °C
Storage and transport temperature, maximum
+85 °C
Relative humidity, minimum
30 %
Relative humidity, maximum
95 %
Note (Relative humidity)
non-condensing
Protection class
II

Mechanical data - Connection technique

Termination
1 NO contacts/1 NC contact
Length of cable
2 m
Wire cross-section
0.23 mm
Wire cross-section
23 AWG

Approvals - Standards

Certificates
cULus

Status indication

Note (LED switching conditions display)