Electrical data
- Current consumption
- 50 mA
Electrical data - AS-Interface specification
- AS-i Version
- V 2.1
- AS-i Profile
- S-7.B.F.E
- AS-i, IO-Code
- 0x7
- AS-i, ID-Code
- 0xB
- AS-i, ID-Code1
- 0xF
- AS-i, ID-Code2
- 0xE
- AS-i Input, Channel 1
- Data bits DI 0 / DI 1 = dynamic code transmission
- AS-i Input, Channel 2
- Data bits DI 2 / DI 3 = dynamic code transmission
- AS-i Outputs, DO 0 … DO 3
- No Function
- AS-i Parameter bits, P0 ... P3
- No function
- Note (AS-i Parameter bits)
- Set the parameter outputs to "1111" (0xF) | FID: periphery error
- AS-i Input module address
- 0
- Note (AS-i Input module address)
- Preset to address 0, can be changed through AS-interface bus master or hand-held programming device
Mechanical data - Dimensions
- Diameter of sensor
- 28 mm
- Height of sensor
- 86.5 mm
Pin assignment
- Connection
- AS-i connection
- PIN 1
- Brown (AS interface +)
- PIN 2
- n.c.
- PIN 3
- Blue (AS interface −)
- PIN 4
- n.c.
- Connection
- Sensor connection
- PIN 1
- Brown - Normally open contact (NO)
- PIN 2
- Blue - Normally open contact (NO)
- PIN 3
- White - Opener (NC)
- PIN 4
- Black - Opener (NC)
Ambient conditions - Insulation values
- Rated insulation voltage U
- 32 VDC
- Rated impulse withstand voltage U
- 0.8 kV
- Overvoltage category
- III
- Degree of pollution
- 3
General data - Features
- Cross-circuit detection
- Yes
- Integral system diagnostics, status
- Yes
- Number of inputs for NC
- 1
- Number of inputs for NO
- 1
- Number of pre-wired cable
- 2
General data
- Standards
- EN 50295 | EN ISO 13849-1 | EN IEC 60947-5-1 | EN IEC 61508
- Connector (electric)
- AS-i Terminal: Pre-wired cable, 2-pole | Sensor connection: pre-wired cable 4-pole
- Enclosure material
- Plastic, glass-fibre reinforced thermoplastic, self-extinguishing
Safety classification
- Standards
- EN IEC 61508
- Performance Level, up to
- e
- Category
- 4
- PFH value
- 2.04 x 10⁻⁹ /h
- Safety Integrity Level (SIL), suitable for applications in
- 3
- Mission time
- 20 Year(s)
Electrical data - AS Interface
- Rated operating voltage
- 26.5 ... 31.6 VDC (Protection against polarity reversal)
Ambient conditions
- Degree of protection
- IP67
- Ambient temperature
- -25 ... +55 °C
- Storage and transport temperature, minimum
- -25 °C
- Storage and transport temperature, maximum
- +85 °C
- Relative humidity, minimum
- 30 %
- Relative humidity, maximum
- 95 %
- Note (Relative humidity)
- non-condensing
- Protection class
- II
Mechanical data - Connection technique
- Termination
- 1 NO contacts/1 NC contact
- Length of cable
- 2 m
- Wire cross-section
- 0.23 mm
- Wire cross-section
- 23 AWG
Status indication
- Note (LED switching conditions display)