Schmersal

101176606

SRB207AN/1-230VAC
101176606
101176606
101176606
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

Electrical data

Frequency range
50 Hz | 60 Hz
Rated operating voltage
48 ... 240 VAC
Rated AC voltage for controls, 50 Hz, minimum
48 VAC
Rated control voltage at AC 50 Hz, maximum
240 VAC
Rated AC voltage for controls, 60 Hz, minimum
48 VAC
Rated control voltage at AC 60 Hz, maximum
240 VAC
Utilisation category AC-15
230 VAC
Utilisation category AC-15
6 A
Utilisation category DC-13
24 VDC
Utilisation category DC-13
6 A
Electrical power consumption
6.8 W
Contact resistance, maximum
0.1 Ω
Note (Contact resistance)
in new state
Drop-out delay in case of "emergency stop", maximum
20 ms
Pull-in delay at automatic start, maximum, typically
120 ms
Pull-in delay at RESET, typically
30 ms
Material of the contacts, electrical
AgSn0. self-cleaning, positive drive

Note

Note (General)
Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit.

Mechanical data - Dimensions

Width
45 mm
Height
100 mm
Depth
121 mm

Ambient conditions - Insulation values

Rated impulse withstand voltage U
4 kV
Overvoltage category
II
Degree of pollution
2

General data - Features

Stop-Category
0
Electronic Fuse
Yes
Wire breakage detection
Yes
Cross-circuit detection
Yes
Removable Terminals
Yes
Start input
Yes
Feedback circuit
Yes
Automatic reset function
Yes
Reset edge detection
Yes
Earth connection detection
Yes
Integral system diagnostics, status
Yes
Number of auxiliary contacts
1 | 7
Number of LEDs
3
Number of normally closed (NC)
6
Number of normally open (NO)
6
Number of safety contacts
2
Number of signalling outputs
6

General data

Standards
EN IEC 62061 | EN ISO 13849-1 | EN IEC 60947-5-1 | EN IEC 60947-5-3 | EN IEC 60947-5-5 | EN IEC 61508 | EN IEC 60204-1 | EN IEC 60947-1
Climatic stress
EN 60068-2-78
Enclosure material
Glass-fibre reinforced thermoplastic, ventilated
Gross weight
400 g

Safety classification

Standards
EN IEC 60947-5-1 | EN IEC 61508
Performance Level, stop 0, up to
d
Category, Stop 0
3
Diagnostic Coverage (DC) Level, Stop 0
≥ 99 %
PFH value, Stop 0
2.00 x 10⁻⁷ /h
Safety Integrity Level (SIL), Stop 0, suitable for applications in
2
Mission time
20 Year(s)
Common Cause Failure (CCF), minimum
65

Wiring example

Note (Wiring diagram)
The wiring diagram is shown with guard doors closed and in de-energised condition. | The feedback circuit monitors the position of the contactors K3 and K4. | Automatic start: The automatic start is programmed by connecting the feedback circuit to the terminals X1/X3. If the feedback circuit is not required, establish a bridge. | To secure 6 guard doors up to PL d and Category 3 | Monitoring 6 guard door(s), each with a magnetic safety sensor of the BNS range | Start button (S) with edge detection

Other data

Note (applications)
Safety sensor | Guard system | Emergency-Stop button | Pull-wire emergency stop switches

Ambient conditions

Degree of protection of the enclosure
IP40
Degree of protection of the mounting space
IP54
Degree of protection of clips or terminals
IP20
Ambient temperature
-25 ... +45 °C
Storage and transport temperature, minimum
-40 °C
Storage and transport temperature, maximum
+85 °C
Resistance to vibrations
10...55 Hz, Amplitude 0.35 mm, ± 15 %
Restistance to shock
10 g / 11 ms

Mechanical data - Connection technique

Termination
rigid or flexible | Screw terminals M20 x 1.5
Terminal designations
IEC/EN 60947-1
Cable section, minimum
0.25 mm²
Cable section, maximum
2.5 mm²
Tightening torque of Clips
0.6 Nm

Mechanical data

Mechanical life, minimum
10,000,000 Operations
Mounting
Snaps onto standard DIN rail to EN 60715

Specifications

Width
45 mm
Height
100 mm
Depth
121 mm

Electrical data - Electromagnetic compatibility (EMC)

EMC rating
EMC-Directive

Electrical data - Digital inputs

Conduction resistance, maximum
40 Ω

Status indication

Indicated operating states
Position relay K2 | Position relay K1 | Internal operating voltage U