101181682

AES 2355 UE: 24...230V AC/DC
101181682
101181682
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up

Electrical data - Relay outputs (auxiliary contacts)

Switching capacity, maximum
24 VDC
Switching capacity, maximum
2 A

Electrical data

Frequency range
50 Hz | 60 Hz
Thermal test current
6 A
Rated operating voltage
24 ... 230 VAC | 24 ... 230 VDC
Rated AC voltage for controls, 50 Hz, minimum
20.4 VAC
Rated control voltage at AC 50 Hz, maximum
253 VAC
Rated AC voltage for controls, 60 Hz, minimum
20.4 VAC
Rated control voltage at AC 60 Hz, maximum
253 VAC
Rated AC voltage for controls at DC minimum
20.4 VDC
Rated control voltage at DC, maximum
253 VDC
Electrical power consumption
5 W
Contact resistance, maximum
0.1 Ω
Note (Contact resistance)
in new state
Drop-out delay in case of power failure, typically
80 ms
Drop-out delay in case of emergency, typically
20 ms
Pull-in delay at automatic start, maximum, typically
100 ms
Pull-in delay at RESET, typically
20 ms
Material of the contacts, electrical
Ag-Ni 10 and 0.2 µm gold-plated

Note

Note (General)
Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit.

Mechanical data - Dimensions

Width
45 mm
Height
100 mm
Depth
121 mm

Ambient conditions - Insulation values

Rated impulse withstand voltage U
4 kV
Overvoltage category
III
Degree of pollution
2

Electrical data - Digital Output

Voltage, Utilisation category DC-12
24 VDC
Current, Utilisation category DC-12
0.1 A

General data - Features

Stop-Category
0
Wire breakage detection
Yes
Cross-circuit detection
Yes
Feedback circuit
Yes
Automatic reset function
Yes
Reset after disconnection of supply voltage
Yes
Integral system diagnostics, status
Yes
Number of LEDs
1
Number of normally closed (NC)
2
Number of normally open (NO)
2
Number of undelayed semi-conductor outputs with signaling function
2
Number of safety contacts
3
Number of signalling outputs
2

General data

Standards
BG-GS-ET-14 | BG-GS-ET-20 | EN IEC 62061 | EN IEC 60947-5-1 | EN IEC 60947-5-3 | EN IEC 60947-5-5 | EN IEC 61508 | EN IEC 60204-1 | EN IEC 60947-1
Climatic stress
BG-GS-ET-14 | IEC 60947-5-3
Enclosure material
Glass-fibre, reinforced thermoplastic
Gross weight
309 g

Safety classification

Standards
EN ISO 13849-1 | EN IEC 61508
Performance Level, up to
d
Category
3
PFH value
1.00 x 10⁻⁷ /h
Notice
for max. 50,000 switching cycles/year and max. 80% contact load
Safety Integrity Level (SIL), suitable for applications in
2
Mission time
20 Year(s)

Wiring example

Note (Wiring diagram)
The wiring diagram is shown with guard doors closed and in de-energised condition. | Monitoring 2 guard door(s), each with a magnetic safety sensor of the BNS range | To secure a guard door up to PL d and Category 3 | If one or two external relays or contactors are used to switch the load, the system can then only be classified in Category 3 to EN ISO 13849-1, if exclusion of the fault “Failure of the external contactors” can be substantiated and is documented, e.g. by using reliable down-rated contactors. A second contactor leads to an increase in the level of security by redundant switching to switch the load off. | The ISD tables (Intergral System Diagnostics) for analysis of the fault indications and their causes are shown in the appendix.

Other data

Note (applications)
Safety sensor | Guard system

Ambient conditions

Degree of protection of the enclosure
IP40
Degree of protection of the mounting space
IP54
Degree of protection of clips or terminals
IP20
Ambient temperature
+0 ... +55 °C
Storage and transport temperature, minimum
-25 °C
Storage and transport temperature, maximum
+70 °C
Resistance to vibrations
10...55 Hz, Amplitude 0.35 mm, ± 15 %
Restistance to shock
30 g / 11 ms

Mechanical data - Connection technique

Termination
rigid or flexible | Screw terminals M20 x 1.5
Terminal designations
IEC/EN 60947-1
Cable section, minimum
0.25 mm²
Cable section, maximum
2.5 mm²
Tightening torque of Clips
0.6 Nm

Electrical data - Safe relay outputs

Voltage, Utilisation category AC-15
230 VAC
Current, Utilisation category AC-15
3 A
Voltage, Utilisation category DC-13
24 VDC
Current, Utilisation category DC-13
2 A
Switching capacity, minimum
10 VDC
Switching capacity, minimum
10 mA
Switching capacity, maximum
250 VAC
Switching capacity, maximum
8 A

Mechanical data

Mechanical life, minimum
20,000,000 Operations
Mounting
Snaps onto standard DIN rail to EN 60715

Specifications

Width
45 mm
Height
100 mm
Depth
121 mm

Approvals - Standards

Certificates
BG | cULus

Electrical data - Electromagnetic compatibility (EMC)

EMC rating
EMC-Directive

Electrical data - Digital inputs

Input signal, HIGH Signal "1"
10 … 30 VDC
Input signal, LOW Signal "0"
0 … 2 VDC
Conduction resistance, maximum
40 Ω

Integral system diagnosis (ISD)

Note (ISD -Faults)
The following faults are registered by the safety monitoring modules and indicated by ISD.
Faults
Failure of the safety relay to pull-in or drop-out | Failure of door contacts to open or close | Cross-wire or short-circuit monitoring of the switch connections | Interruption of the switch connections | Fault on the input circuits or the relay control circuits of the safety monitoring module